Publications by authors named "Jennifer N Lehrman"

Study Design: In vitro biomechanical study.

Objective: This study aimed to investigate the biomechanical effects of facet joint violation (FV) on mobility and optically tracked intervertebral disc (IVD) surface strains at the upper level adjacent to L4-5 pedicle screw-rod fixation.

Summary Of Background Data: FV is a complication that can occur when placing lumbar pedicle screws; the reported incidence is as high as 50%.

View Article and Find Full Text PDF

Background: The objective of this study was to assess the pullout force of a novel sharp-tipped screw developed for single-step, minimally invasive pedicle screw placement guided by neuronavigation compared with the pullout force for traditional screws.

Methods: A total of 60 human cadaveric lumbar pedicles were studied. Three different screw insertion techniques were compared: (A) Jamshidi needle and Kirschner wire without tapping; (B) Jamshidi needle and Kirschner wire with tapping; and (C) sharp-tipped screw insertion.

View Article and Find Full Text PDF

Study Design: This was a laboratory investigation.

Objective: Rod attachment can induce significant pedicle screw-and-rod pre- strain that may predispose the instrumentation to failure. This study investigated how in vitro L5-S1 rod strain and S1 screw strain during rod-screw attachment (pre-strain) compared with strains recorded during pure-moment bending ( test- strain).

View Article and Find Full Text PDF

Objective: The high mechanical stress zone at the sudden transition from a rigid to flexible region is involved in proximal junctional kyphosis (PJK) physiopathology. We evaluated the biomechanical performance of polyetheretherketone (PEEK) rods used as a nontraditional long semirigid transition phase from a long-segment metallic rod construct to the nonfused thoracic spine.

Methods: Pure moment range of motion (ROM) tests (7.

View Article and Find Full Text PDF

Background: Adjacent level degeneration is a precursor to construct failure in adult spinal deformity surgery, but whether construct design affects adjacent level degeneration risk remains unclear. Here we present a biomechanical profile of common deformity correction constructs and assess adjacent level biomechanics.

Methods: Standard nondestructive flexibility tests (7.

View Article and Find Full Text PDF

Objective: Changes to segmental lordosis at a single level may affect adjacent-level biomechanics and overall spinal alignment with an iatrogenic domino effect commonly seen in adult spinal deformity. This study investigated the effects of different segmental angles of single-level lumbar fixation on stability and principal strain across the surface of the adjacent-level disc.

Methods: Seven human cadaveric L3-S1 specimens were instrumented at L4-5 and tested in 3 conditions: 1) neutral native angle ("neutral"), 2) increasing angle by 5° of lordosis ("lordosis"), and 3) decreasing angle by 5° of kyphosis ("kyphosis").

View Article and Find Full Text PDF

Few studies have used optical full-field surface strain mapping to study spinal biomechanics. We used a commercial digital imaging correlation (DIC) system to (1) compare posterior surface strains on spinal rods with those obtained from conventional foil strain gauges, (2) quantify bony vertebral body and intervertebral disc (IVD) surface strains on 3 L3-S cadaveric spines during gold-standard flexibility tests (7.5-Nm flexion-extension and 400-N compression), and (3) report our experience with the application and feasibility of DIC to comprehensively map strain in spinal biomechanics.

View Article and Find Full Text PDF

Study Design: Fourteen cadaveric specimens were separated into two groups: (1) L3 pedicle subtraction osteotomy (PSO) with transforaminal lumbar interbody fusion (TLIF) or (2) lateral lumbar interbody fusion (LLIF). A 2-rod configuration (2R) was compared with two supplemental rod configurations: 4-rod (4R) with accessory rods (ARs) using connectors or 4R with satellite rods (SRs) without connectors.

Objective: Compare PSO constructs with different rod configurations and adjacent-level interbody support.

View Article and Find Full Text PDF

Objective: To compare biomechanical stability and rod strain among uniform rod (UR), tapered rod (TR), and UR+accessory rod (AR) constructs in a human cadaveric C7 pedicle subtraction osteotomy (PSO) model of cervical deformity correction.

Methods: Fourteen human cadaveric C2-T4 specimens were divided into 2 statistically equivalent groups. Specimens were instrumented from C2 to T3, and a 25° PSO was performed at C7.

View Article and Find Full Text PDF

Study Design: Biomechanical study of range of motion (ROM) at the vertebral levels adjacent to the construct of posterior pedicle screw-rod fixation with different types of lumbar interbody fusion techniques (LIF).

Objective: To investigate the differences in adjacent segment mobility among three types of LIF: lateral lumbar interbody fusion (LLIF), transforaminal lumbar interbody fusion (TLIF), and posterior lumbar interbody fusion (PLIF).

Summary Of Background Data: Previous studies have concluded that LLIF, TLIF, and PLIF with posterior pedicle screw-rod fixation (PSR) provide equivalent stability in cadaveric specimens and are comparable in fusion rate and functional outcome.

View Article and Find Full Text PDF

Objective: The lordotic shape of the lumbar spine differs substantially between individuals. Measuring and recording strain during spinal biomechanical tests is an effective method to infer stresses on spinal implants and predict failure mechanisms. The geometry of the spine may have a significant effect on the resultant force distribution, thereby directly affecting rod strain.

View Article and Find Full Text PDF

Objective: S2 alar-iliac (S2AI) screw fixation effectively enhances stability in long-segment constructs. Although S2AI fixation provides a single transarticular sacroiliac joint fixation (SIJF) point, additional fixation points may provide greater stability and attenuate screw and rod strain. The objectives of this study were to evaluate changes in stability and pedicle screw and rod strain with extended distal S2AI fixation and with supplemental bilateral integration of two sacroiliac joint fusion devices implanted using a traditional minimally invasive surgical approach.

View Article and Find Full Text PDF

Objective: Anterior column realignment (ACR) is a new minimally invasive approach for deformity correction that achieves a degree of lordosis similar to that obtained with pedicle subtraction osteotomy (PSO). This study compared the biomechanical profiles of ACR with PSO using range of motion (ROM) and posterior rod strain (RS) to gain insight into the ACR technique and the necessary surgical strategies to optimize longevity and stability.

Methods: An in vitro biomechanical study using standard flexibility testing (7.

View Article and Find Full Text PDF

Objective: Cortical screw-rod (CSR) fixation has emerged as an alternative to the traditional pedicle screw-rod (PSR) fixation for posterior lumbar fixation. Previous studies have concluded that CSR provides the same stability in cadaveric specimens as PSR and is comparable in clinical outcomes. However, recent clinical studies reported a lower incidence of radiographic and symptomatic adjacent-segment degeneration with CSR.

View Article and Find Full Text PDF

Objective: S2-alar-iliac (S2AI) screw fixation effectively ensures stability and enhances fusion in long-segment constructs. Nevertheless, pelvic fixation is associated with a high rate of mechanical failure. Because of the transarticular nature of the S2AI screw, adding a second point of fixation may provide additional stability and attenuate strains.

View Article and Find Full Text PDF

Objective: Anterior cervical discectomy and fusion (ACDF) is a common procedure for the treatment of cervical disease. Circumferential procedures are options for multilevel pathology. Potential complications of multilevel anterior procedures are dysphagia and pseudarthrosis, whereas potential complications of posterior surgery include development of cervical kyphosis and postoperative chronic neck pain.

View Article and Find Full Text PDF

Background: The risk of interlaminar passage of a dilator into the lumbar spinal canal in minimally invasive approaches is currently unknown. Among anthropometric data reported in the medical literature, there is no cadaveric report of the interlaminar dimensions of the lumbar spine.

Objective: To report the lumbar interlaminar dimensions in neutral, flexion, and extension postures.

View Article and Find Full Text PDF

Objective: The objective of this study was to evaluate a novel connector design and compare it with traditional side connectors, such as a fixed-angle connector (FAC) and a variable-angle connector (VAC), with respect to lumbosacral stability and instrumentation strain.

Methods: Standard nondestructive flexibility tests (7.5 Nm) and compression tests (400 N) were performed using 7 human cadaveric specimens (L1-ilium) to compare range of motion (ROM) stability, posterior rod strain (RS), and sacral screw bending moment (SM).

View Article and Find Full Text PDF

Study Design: Biomechanical model study.

Objective: The Barrow Biomimetic Spine (BBS) project is a resident-driven effort to manufacture a synthetic spine model with high biomechanical fidelity to human tissue. The purpose of this study was to investigate the performance of the current generation of BBS models on biomechanical testing of range of motion (ROM) and axial compression and to compare the performance of these models to historical cadaveric data acquired using the same testing protocol.

View Article and Find Full Text PDF

Background: Biomechanical properties of intact spinal motion segments are used to establish baseline values during in vitro studies evaluating spinal surgical techniques and implants. These properties are also used to validate computational models (ie, patient-specific finite element models) of human lumbar spine segments. Our laboratory has performed a large number of in vitro mechanical studies of lumbar spinal segments, using a consistent methodology.

View Article and Find Full Text PDF

Background: The risk of interlaminar passage of a dilator into the cervical spinal canal in minimally invasive approaches is currently unknown. Among the various anthropometric data reported in the literature, there is no report of the interlaminar dimensions in the cervical spine.

Objective: To report the cervical interlaminar dimensions in neutral, flexion, and extension.

View Article and Find Full Text PDF

This study used a 3-dimensional (3D) craniocervical junction model of styloidogenic jugular venous compression (SJVC) syndrome to simulate and evaluate intracranial pressure (ICP) after internal jugular vein (IJV) compression by an elongated styloid process during axial rotation. The 3D-printed model created using data from an SJVC-syndrome patient included an articulating occipital-cervical junction, simplified arteriovenous system, gauge to measure simulated ICP, fixed obstruction simulating left-sided venous occlusion, and right-sided vascular tubing to simulate IJV compression. The model was rotated axially to its extreme right and left; maximum degree of motion and pressure were recorded for 3 cycles.

View Article and Find Full Text PDF

Background Context: Anterior column realignment (ACR) is a powerful but destabilizing minimally invasive technique for sagittal deformity correction. Optimal biomechanical design of the ACR construct is unknown.

Purpose: Evaluate the effect of ACR design on radiographic lordosis, range of motion (ROM) stability, and rod strain (RS) in a cadaveric model.

View Article and Find Full Text PDF

Objective: Minimally invasive transforaminal interbody fusion techniques vary among surgeons. One decision point is whether to perform a unilateral facetectomy (UF), a unilateral facetectomy plus partial contralateral facetectomy (UF/PF), or a complete bilateral facetectomy (CBF). The authors therefore compared the biomechanical benefits of all 3 types of facetectomies to determine which approach produces improved biomechanical outcomes.

View Article and Find Full Text PDF

Objective: Transforaminal lumbar interbody fusion (TLIF) is commonly used for lumbar fusion, such as for foraminal decompression, stabilization, and improving segmental lordosis. Although many options exist, surgical success is contingent on matching design strengths with surgical goals. The goal in the present study was to investigate the effects of an expandable interbody spacer and 2 traditional static spacer designs in terms of stability, compressive stiffness, foraminal height, and segmental lordosis.

View Article and Find Full Text PDF