Healthcare in the United States has become increasingly digital since the passage of the HITECH Act in 2009. As a result, there is a growing need to optimize healthcare IT to allow for the interoperable exchange of data. As a result, the Office of the National Coordinator for Health IT has implemented their Final Rule for the 21st Century Cures Act.
View Article and Find Full Text PDFObjectives: To determine the frequency of use of laboratory-developed tests (LDTs) in an academic medical center system.
Methods: Retrospective analysis of 2021 test order data from an academic medical center (hospital, outpatient clinics, and cancer center) was done. Measures included assay type, assay methodology, regulatory status, test order volume, inpatient vs outpatient setting, and provider medical specialty.
Background: Numerous serology assays are available for detection of SARS-CoV-2 antibodies but are limited in that only 1 or 2 target antigen(s) can be tested at a time. Here, we describe a novel multiplex assay that simultaneously detects and quantifies IgG antibodies to SARS-CoV-2 antigens, spike (S), nucleocapsid (N), receptor-binding domain (RBD), and N-terminal domain (NTD) in a single well.
Methods: Sensitivity was determined using samples (n = 124) from confirmed SARS-CoV-2 RT-PCR positive individuals.
Arch Pathol Lab Med
October 2021
Context.—: Emerging evidence shows correlation between the presence of neutralization antibodies (nAbs) and protective immunity against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Currently available commercial serology assays lack the ability to specifically identify nAbs.
View Article and Find Full Text PDFBackground: Virus neutralization by antibodies is an important prognostic factor in many viral diseases. To easily and rapidly measure titers of neutralizing antibodies in serum or plasma, we developed pseudovirion particles composed of the spike glycoprotein of SARS-CoV-2 incorporated onto murine leukemia virus capsids and a modified minimal murine leukemia virus genome encoding firefly luciferase. This assay design is intended for use in laboratories with biocontainment level 2 and therefore circumvents the need for the biocontainment level 3 that would be required for replication-competent SARS-CoV-2 virus.
View Article and Find Full Text PDFBackground: As serologic assays for SARS-CoV-2 become more widely utilized, it is important to understand their performance characteristics and correlation with neutralizing antibodies. We evaluated 3 commonly used SARS-CoV-2 IgG assays (Abbott, DiaSorin, and EUROIMMUN) for clinical sensitivity, specificity, and correlation with neutralizing antibodies, and then compared antibody kinetics during the acute phase of infection.
Methods: Three panels of samples were tested on every assay.
Antibody neutralization is an important prognostic factor in many viral diseases. To easily and rapidly measure titers of neutralizing antibodies in serum or plasma, we developed pseudovirion particles composed of the spike glycoprotein of SARS-CoV-2 incorporated onto murine leukemia virus capsids and a modified minimal MLV genome encoding firefly luciferase. These pseudovirions provide a practical means of assessing immune responses under laboratory conditions consistent with biocontainment level 2.
View Article and Find Full Text PDFBackground: Host factors play an important role in pathogenesis and disease outcome in infection (CDI), and characterization of these responses could uncover potential host biomarkers to complement existing microbe-based diagnostics.
Methods: We extracted RNA from fecal samples of patients with CDI and profiled human mRNA using amplicon-based next-generation sequencing (NGS). We compared the fecal host mRNA transcript expression profiles of patients with CDI to controls with non-CDI diarrhea.
This multicenter study was designed to assess the accuracy and reproducibility of the Vitek MS v3.0 matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry system for identification of and species compared to DNA sequencing. A total of 963 clinical isolates representing 51 taxa were evaluated.
View Article and Find Full Text PDFInvasive fungal infections are an important cause of morbidity and mortality affecting primarily immunocompromised patients. While fungal identification to the species level is critical to providing appropriate therapy, it can be slow and laborious and often relies on subjective morphological criteria. The use of matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry has the potential to speed up and improve the accuracy of identification.
View Article and Find Full Text PDFWe evaluated immune responses following bivalent oral cholera vaccination (Shanchol [Shantha Biotechnics]; BivWC) in a cohort of 25 human immunodeficiency virus (HIV)-infected adults in Haiti. Compared with adults without HIV infection, vaccination in HIV-infected individuals resulted in lower vibriocidal responses against Vibrio cholerae O1, and there was a positive relationship between the CD4(+) T-cell count and vibriocidal responses following vaccination. Nevertheless, seroconversion occurred at a rate of 65% against the Ogawa serotype and 74% against the Inaba serotype in adults with HIV infection.
View Article and Find Full Text PDFWe evaluated the use of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MS) for the identification of Vibrio cholerae. MS identified all 42 isolates of V. cholerae O1 and O139 and 7 of 9 non-O1/O139 isolates.
View Article and Find Full Text PDFBackground: Infections with cytomegalovirus (CMV) and Epstein-Barr virus (EBV) remain important in solid organ transplantation. Quantitative viral nucleic acid testing is a major advance to patient management. These assays are limited by a lack of standardization, resulting in viral load measurements that differ among clinical laboratories.
View Article and Find Full Text PDFInflammation in early human immunodeficiency virus type 1 (HIV-1) disease progression is not well characterized. Ninety patients with untreated primary HIV-1 infection were studied to determine associations of inflammatory proteins with early disease progression. High plasma tumor necrosis factor α (TNF-α) levels (≥8.
View Article and Find Full Text PDFThe VITEK MS v2.0 MALDI-TOF mass spectrometry system's performance in identifying fastidious gram-negative bacteria was evaluated in a multicenter study. Compared with the reference method (DNA sequencing), the VITEK MS system provided an accurate, species-level identification for 96% of 226 isolates; an additional 1% were accurately identified to the genus level.
View Article and Find Full Text PDFBackground: HLA-B alleles are associated with viral control in chronic HIV-1 infection, however, their role in primary HIV-1 disease is unclear. This study sought to determine the role of HLA-B alleles in viral control during the acute phase of HIV-1 infection and establishment of the early viral load set point (VLSP).
Findings: Individuals identified during primary HIV-1 infection were HLA class I typed and followed longitudinally.
The Vitek MS v2.0 matrix-assisted laser desorption ionization-time of flight mass spectrometry system accurately distinguished Streptococcus pneumoniae from nonpneumococcal S. mitis group species.
View Article and Find Full Text PDFThe optimal management of fungal infections is correlated with timely organism identification. Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) is revolutionizing the identification of yeasts isolated from clinical specimens. We present a multicenter study assessing the performance of the Vitek MS system (bioMérieux) in identifying medically important yeasts.
View Article and Find Full Text PDFMatrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF) is gaining momentum as a tool for bacterial identification in the clinical microbiology laboratory. Compared with conventional methods, this technology can more readily and conveniently identify a wide range of organisms. Here, we report the findings from a multicenter study to evaluate the Vitek MS v2.
View Article and Find Full Text PDF