Publications by authors named "Jena L Nawfel"

Studies have shown that closed-loop myoelectric control schemes can lead to changes in user performance and behavior compared to open-loop systems. When users are placed within the control loop, such as during real-time use, they must correct for errors made by the controller and learn what behavior is necessary to produce desired outcomes. Augmented feedback, consequently, has been used to incorporate the user throughout the training process and to facilitate learning.

View Article and Find Full Text PDF

Pattern recognition techniques leveraging the use of electromyography signals have become a popular approach to provide intuitive control of myoelectric devices. Performance of these control interfaces is commonly quantified using offline classification accuracy, despite studies having shown that this metric is a poor indicator of usability. Researchers have identified alternative offline metrics that better correlate with online performance; however, the relationship has yet to be fully defined in the literature.

View Article and Find Full Text PDF