Publications by authors named "Jelle J Halma"

- The long-term survival of arthroplasty components may be limited by polyethylene wear-related problems such as periprosthetic osteolysis and aseptic loosening. Highly cross-linked polyethylene (HXLPE) blended with vitamin E was introduced to improve oxidative stability and to avoid long-term embrittlement. This study clinically compares the tribological behavior and clinical outcome of vitamin E blended HXLPE with ultra-high molecular weight polyethylene (UHMWPE) in an isoelastic monoblock cup for uncemented total hip arthroplasty.

View Article and Find Full Text PDF

Introduction: The objective of the present study was to review the current data on the long-term outcomes of posterior malleolar fractures, with special emphasis on the role of the type of treatment, surgical approach, and reduction and internal fixation.

Methods: The search was limited to skeletally mature patients. Major databases were searched from 1978 to 2014 to identify studies relating to functional outcome, subjective outcome, and radiographic evaluation at least 2 years after either surgical or conservative treatment of posterior malleolar fractures.

View Article and Find Full Text PDF

Little is known about the clinical application of highly cross-linked polyethylene (HXLPE) blended with vitamin E. This study evaluates an uncemented iso-elastic monoblock cup with vitamin E blended HXLPE. 112 patients were followed up for 2years.

View Article and Find Full Text PDF

Purpose: We evaluated the 5-year survival of the uncemented Optan anatomically adapted femoral stem, with revision for aseptic loosening as the endpoint.

Methods: Between January 2004 and March 2007, 432 total hip arthroplasties (THAs) were performed in 432 patients. After follow-up for a mean time of 5 years, the patients were evaluated using the WOMAC questionnaire and plain radiography.

View Article and Find Full Text PDF

The mal-positioning of total hip arthroplasty components can result in edge loading conditions. Purpose of this study was to determine if the wear rate of ceramic-on-ceramic and metal-on-polyethylene increases under edge loading conditions. The literature was reviewed to determine which of the commonly used hip bearings is the most forgiving to implant mal-orientation.

View Article and Find Full Text PDF

Background: Monoblock acetabular components used in uncemented total hip arthroplasty (THA) have certain mechanical characteristics that potentially reduce acetabular osteolysis and polyethylene wear. However, the degree to which they achieve this goal is not well documented.

Questions/purposes: The purpose of this study was to use a systematic review of controlled trials to test the hypothesis that monoblock cups have superior (1) polyethylene wear rate; (2) frequency of cup migration; (3) frequency of acetabular osteolysis; and (4) frequency of aseptic loosening compared with modular components used in uncemented THA.

View Article and Find Full Text PDF

The Morscher monoblock cup is designed for optimal osteointegration and holds the potential for excellent long-term survival. The Metasul-on-Metasul bearing was introduced to eliminate wear-induced periprosthetic osteolysis. This study reviews 137 Morscher cups with a 28-mm Metasul-on-Metasul bearing used in primary THA at 5.

View Article and Find Full Text PDF