Our study presents cases demonstrating the technique and safety of percutaneous occlusion of adult patients with partial anomalous pulmonary venous return (PAPVR). PAPVR is a rare condition that is traditionally treated surgically. Percutaneous interventions are rarely reported.
View Article and Find Full Text PDFPurpose: To evaluate the outcomes of early primary stent placement (within 30 days of liver transplantation) for hepatic artery stenosis (HAS).
Methods: Patients who underwent liver transplantation between 02/2001 and 02/2024 were evaluated for hepatic artery stenosis. Patients who underwent primary stent placement were selected and stratified based on the time from anastomosis to intervention.
The objective of this study was to measure the contemporary patency rates and frequency of interventions required for arteriovenous fistula (AVF) care in a representative US population of patients with end-stage kidney disease, including by age, race, and gender. All Medicare beneficiaries aged >20 years who underwent AVF graft creation for end-stage kidney disease between 2017 and 2019 were included for analysis. The primary end points included primary patency, primary assisted patency, postintervention patency, and fistula functionality up to 1 year after AVF placement.
View Article and Find Full Text PDFPurpose: To evaluate the safety and efficacy of ultrasound-guided percutaneous thrombin injection for the treatment of upper extremity pseudoaneurysms.
Methods: An institutional database containing 8,316,467 radiology reports was searched for suitable cases over a 241-month period. Fourteen female and 10 male patients, average age of 69.
Cardiovasc Intervent Radiol
October 2024
Purpose: To evaluate the effect of being under time pressure on procedural performance using hand motion analysis.
Materials And Methods: Eight radiology trainees performed central venous access on a phantom while recording video and hand motion data using an electromagnetic motion tracker. Each trainee performed the procedure six times: the first three trials without any prompts (control), while for the next three, they were asked to perform the task as fast as possible (time pressure).
Background: Despite advances in therapy options, pulmonary embolism (PE) continues to carry a high risk of mortality and morbidity. Currently, therapeutic options are limited with only 2 US Food and Drug Administration-cleared catheter-based embolectomy devices approved for the treatment of intermediate-risk PE. The novel Hēlo PE thrombectomy catheter (Endovascular Engineering, Inc) has a flexible and collapsible funnel with an internal agitator for a dual mechanism of treatment for acute PE.
View Article and Find Full Text PDFSurgical site infections (SSI) remain a cause of morbidity, prolonged hospitalization, surgical readmission, and death. Nasal colonization with methicillin-resistant Staphylococcal aureus is a frequent cause of device-related SSI and nasal mupirocin has been used for prevention. More recently, povidone-iodine nasal swabs have become an alternative.
View Article and Find Full Text PDFPurpose: To compare the impact of a commercial tracking database on inferior vena cava filter retrievals with that of physician tracking and no tracking.
Materials And Methods: From January 2013 to December 2021, 532 filters were placed at a single institution and followed in 3 phases: (a) Phase 1, pretracking (January 1, 2013, to February 28, 2015); (b) Phase 2, commercial database tracking (March 1, 2015, to June 30, 2019); and (c) Phase 3, commercial database tracking with separate tracking by an interventional radiologist (July 1, 2019, to December 31, 2021). Patients excluded from the commercial database due to human error served as a control group.
Cardiovasc Intervent Radiol
February 2024
Purpose: There are limited existing data on the lymphatic anatomy of patients with primary lymphedema (LED), which is caused by aberrant development of lymphatic channels. In addition, there is a paucity of contemporary studies that use groin intranodal lymphangiography (IL) to evaluate LED anatomy. The purpose of this retrospective observational study was to better delineate the disease process and anatomy of primary LED using groin IL.
View Article and Find Full Text PDFPurpose: To study the experiences of patients with hepatocellular carcinoma (HCC) contributing to treatment discrepancy in the United States.
Materials And Methods: Using Surveillance, Epidemiology, and End Results data from National Cancer Institute (NCI), Medicare (2002-2015) beneficiaries with HCC who completed a Consumer Assessment of Healthcare Providers and Systems (CAHPS) survey were included. Six CAHPS items (3 global scores: global care rating [GCR], primary doctor rating [PDR], and specialist rating [SR]; 3 composite scores: getting needed care [GNC], getting care quickly [GCQ], and doctor communication [DC]) assessed patient experience.
The purpose of this study is to compare the subjective and objective quality and confidence between conventional angiography with cone-beam computed tomography (CBCT) and magnetic resonance imaging (MRI) for the preoperative evaluation of potential donors for living donor liver transplant. Seventeen patients undergoing preoperative donor evaluation for living donor liver transplantation that underwent angiography with CBCT and contrast-enhanced MRI for evaluation of hepatic vascular anatomy were included in the study. Four attending radiologists interpreted anonymized, randomized angiography with CBCT images and MRIs, rating the diagnostic quality and confidence of their interpretation (on a 3-point scale) for each element, as well as clinically relevant measurements.
View Article and Find Full Text PDFPurpose: To evaluate the ability of hand motion analysis using conventional and new motion metrics to differentiate between operators of varying levels of experience for central venous access (CVA) and liver biopsy (LB).
Materials And Methods: In the CVA task, 7 interventional radiologists (experts), 10 senior trainees, and 5 junior trainees performed ultrasound-guided CVA on a standardized manikin; 5 trainees were retested after 1 year. In the LB task, 4 radiologists (experts) and 7 trainees biopsied a lesion on a manikin.
Purpose: To report the safety and effectiveness of transjugular intrahepatic portosystemic shunt and mechanical thrombectomy (TIPS-thrombectomy) for symptomatic acute noncirrhotic portal vein thrombosis (NC-PVT).
Materials And Methods: Patients with acute NC-PVT who underwent TIPS-thrombectomy between 2014 and 2021 at a single academic medical center were retrospectively reviewed. Thirty-two patients were included (men, 56%; median age, 51 years [range, 39-62 years]).
Background: Point-of-care ultrasound (POCUS) is commonly employed to image the heart, lungs, and abdomen. Rapid ultrasound for shock and hypotension (RUSH) exams are a critical component of POCUS employed in austere environments by Special Operations Forces (SOF) and tactical medics for triage and diagnosis. Despite its utility, training for POCUS remains largely unstandardized with respect to feedback and markers of proficiency.
View Article and Find Full Text PDFPurpose: To assess patient and provider satisfaction with interventional radiology (IR) outpatient telehealth and in-person clinic.
Materials And Methods: This institutional review board-approved study analyzed patient satisfaction with clinic via survey after an IR outpatient telehealth or in-person visit. A physician telehealth experience survey was completed by 8 IR physicians.
Objectives: The study authors hypothesized that a combination of previously used (path length, translational motions, and time) and novel (rotational sum) motion metrics could be used to analyze learning curves of anesthesiology interns (postgraduate year 1) practicing central venous catheter placement in the simulation setting. They also explored the feasibility of using segmented motion recordings to inform deliberate practice.
Design: A prospective cohort study.