Publications by authors named "Jeffrey L Hendricks"

Cochlear implants provide hearing by electrically stimulating the auditory nerve. Implant function can be hindered by device design variables, including electrode size and electrode-to-nerve distance, and cochlear environment variables, including the degeneration of the auditory nerve following hair cell loss. We have developed a dual-component cochlear implant coating to improve both the electrical function of the implant and the biological stability of the inner ear, thereby facilitating the long-term perception of sound through a cochlear implant.

View Article and Find Full Text PDF

A simple approach for creating periodic nano-cavities and periodic stripes of nano-cavity arrays on poly (3,4-ethylene dioxythiophene)-poly(styrenesulfonate) (PEDOT-PSS) thin films using a combination of optical near-field enhancement through self-assembled silica nanospheres and laser interference lithography is presented. Monolayers of close-packed silica nanospheres (800, 600, and 430 nm in diameter) are self-assembled on 2 µm thick PEDOT-PSS electropolymerized films and are subsequently irradiated with 10 ns pulses of 355 nm wavelength laser light. Over areas spanning 2 cm(2), circular nano-cavities with central holes of size 50-200 nm and surrounding craters of size 100-400 nm are formed in the PEDOT-PSS films directly underneath the nanospheres due to strong enhancement (11-18 fold) of the incident light in the near-field, which is confirmed through Mie scattering theory.

View Article and Find Full Text PDF

We investigated using poly(3,4-ethylenedioxythiophene) (PEDOT) to lower the impedance of small, gold recording electrodes with initial impedances outside of the effective recording range. Smaller electrode sites enable more densely packed arrays, increasing the number of input and output channels to and from the brain. Moreover, smaller electrode sizes promote smaller probe designs; decreasing the dimensions of the implanted probe has been demonstrated to decrease the inherent immune response, a known contributor to the failure of long-term implants.

View Article and Find Full Text PDF

The safety, function, and longevity of implantable neuroprosthetic and cardiostimulating electrodes depend heavily on the electrical properties of the electrode-tissue interface, which in many cases requires substantial improvement. While different variations of carbon nanotube materials have been shown to be suitable for neural excitation, it is critical to evaluate them versus other materials used for bioelectrical interfacing, which have not been done in any study performed so far despite strong interest to this area. In this study, we carried out this evaluation and found that composite multiwalled carbon nanotube-polyelectrolyte (MWNT-PE) multilayer electrodes substantially outperform in one way or the other state-of-the-art neural interface materials available today, namely activated electrochemically deposited iridium oxide (IrOx) and poly(3,4-ethylenedioxythiophene) (PEDOT).

View Article and Find Full Text PDF

Chronic microstimulation-based devices are being investigated to treat conditions such as blindness, deafness, pain, paralysis, and epilepsy. Small-area electrodes are desired to achieve high selectivity. However, a major trade-off with electrode miniaturization is an increase in impedance and charge density requirements.

View Article and Find Full Text PDF

Localized cell and drug delivery to the cochlea and central auditory pathway can improve the safety and performance of implanted auditory prostheses (APs). While generally successful, these devices have a number of limitations and adverse effects including limited tonal and dynamic ranges, channel interactions, unwanted stimulation of non-auditory nerves, immune rejection, and infections including meningitis. Many of these limitations are associated with the tissue reactions to implanted auditory prosthetic devices and the gradual degeneration of the auditory system following deafness.

View Article and Find Full Text PDF

A number of biomedical devices require extended electrical communication with surrounding tissue. Significant improvements in device performance would be achieved if it were possible to maintain communication with target cells despite the reactive, insulating scar tissue that forms at the device-tissue interface. Here, we report that the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) can be polymerized directly within living neural tissue resulting in an electrically conductive network that is integrated within the tissue.

View Article and Find Full Text PDF

In this paper, we describe interactions between neural cells and the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) toward development of electrically conductive biomaterials intended for direct, functional contact with electrically active tissues such as the nervous system, heart, and skeletal muscle. We introduce a process for polymerizing PEDOT around living cells and describe a neural cell-templated conducting polymer coating for microelectrodes and a hybrid conducting polymer-live neural cell electrode. We found that neural cells could be exposed to working concentrations (0.

View Article and Find Full Text PDF

Ordered conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) was electrochemically fabricated using a self-assembled medium of surfactant molecules as a template. The morphology and microstructure were extensively investigated by optical and electron microscopy, and results show that the coated films were composed of anisotropic domains having a characteristic size of 15-150 nm. The surfactant-templated ordered PEDOT films were electrochemically deposited on microfabricated neural probes with an electrode site area of 1,256 microm(2).

View Article and Find Full Text PDF