Cases of Gram-negative, anaerobic rod bacteremia and endocarditis have been increasingly recognized in recent years. This increase has been primarily observed in patients at risk for polymicrobial infections, such as those who use injection drugs and patients with diabetes mellitus. Despite a growing incidence, there are few published case reports of cardiac implantable electronic device related endocarditis secondary to Gram negative, anaerobic organisms.
View Article and Find Full Text PDFA 35-year-old man with history of recurrent arrhythmias presented for pulmonary vein isolation. He underwent pre-procedural screening for thromboembolism risk with transesophageal echocardiogram. He had an incidental finding of a rare fenestrated membrane overlying his left atrial appendage.
View Article and Find Full Text PDFAnn Thorac Cardiovasc Surg
February 2020
Purpose: The Convergent procedure is a hybrid, multidisciplinary treatment for symptomatic atrial fibrillation (AF) consisting of minimally invasive surgical epicardial ablation and percutaneous/catheter endocardial ablation. We investigated outcomes following introduction of the Convergent procedure at our institution.
Methods: Retrospective study examining single-center outcomes.
Pacing Clin Electrophysiol
February 2018
Background: "Twiddler's syndrome" occurs when a patient consciously or subconsciously manipulates their pacemaker/defibrillator pulse generator, often resulting in lead dislodgement and device system malfunction. Once dislodgement has occurred, corrective measures include resecuring the system to the pectoralis fascia with redundant anchoring sutures. Unfortunately, patients with Twiddler's syndrome tend to have a high rate of recurrence.
View Article and Find Full Text PDFA 47-year-old man with a history of ischemic cardiomyopathy and chronic systolic heart failure presented after he inadvertently shot himself in the left upper chest with a pneumatic nail gun, penetrating his implantable cardioverter defibrillator (ICD) generator. The device was noninterrogable, consistent with device failure. A new ICD was attached to the existing right ventricular lead, which showed no evidence of traumatic damage and normal lead parameters on interrogation.
View Article and Find Full Text PDFPotential sources of alignment variability not yet investigated with the use of custom cutting guides (CCG) in total knee arthroplasty (TKA) are weight-bearing and lower extremity rotation. This study compared the preoperative planned bone resections created using an MRI-based CCG system to those from 3-dimensional, weight-bearing, full-length lower extremity images in 53 patients undergoing TKA. The angular difference between the proposed resections of the two systems was greater than 2° in 30.
View Article and Find Full Text PDFThe purpose of this study was to determine the percentage of time that patients are therapeutic when prescribed warfarin for chemical thromboprophylaxis following a hip or knee arthroplasty procedure. One hundred eighty-four patients receiving warfarin for 4weeks postoperatively, dosed using a Web-application accounting for patient demographics, INR levels, and concomitant medication use, were included. Patients with a target INR range between 1.
View Article and Find Full Text PDFPacing Clin Electrophysiol
February 2013
Background: Limited data are available regarding the perioperative management of cardiac rhythm management devices (CRMDs) exposed to intraoperative electromagnetic interference. We postulated that implementation of a simple, standardized approach to CRMD management using our own institution's Pacing And Cardioverting Electronic Devices peri-Operative Protocol (the PACED-OP protocol) would be associated with a reduction in the amount of device reprogramming without an increase in CRMD-related complications.
Methods: Records of patients with CRMDs undergoing 497 consecutive surgical procedures were analyzed retrospectively.
Aorto-cameral fistula, either congenital or acquired, is an abnormal connection between the ascending aortic root and one of the cardiac chambers. We report a case of a 61-year-old male with history of atrial fibrillation and 2 radiofrequency ablation procedures, referred to us for surgical Cox Maze procedure. Preoperative cardiac computerized tomography revealed a fistulous connection between the aortic root and the right atrium.
View Article and Find Full Text PDFWe report a 48-year-old male with a rare complication of pacemaker revision-fracture, migration, and secondary endocarditis due to a venous introducer sheath. We illustrate the possible mechanism of injury and discuss approaches to management.
View Article and Find Full Text PDFJ Opt Soc Am A Opt Image Sci Vis
February 2005
We report the first experimental realization of total internal reflection (TIR) diffraction gratings. Performance of less than 0.7-dB insertion loss (IL) for both TE and TM polarizations and 0.
View Article and Find Full Text PDFWe describe a new and unique method for simultaneous determination of the groove depth and duty cycle of binary diffraction gratings. For a near-normal angle of incidence, the +1 and -1 diffracted orders will behave nearly the same as the duty cycle is varied for a fixed grating depth. The difference in their behavior, quantified as the ratio of their respective diffraction efficiencies, is compared to a look-up table generated by rigorous coupled-wave theory, and the duty cycle of the grating is thus obtained as a function of grating depth.
View Article and Find Full Text PDF