Objective: Breast cancer most commonly occurs in the upper outer quadrant (UOQ) chest wall (CW). The effectiveness of routine leaded aprons to protect this region of the body in interventionalists during fluoroscopically guided interventions (FGIs) is unknown. Given the high lifetime attributable risks of prolonged occupational exposure to ionizing radiation and the increasing number of practicing female vascular surgeons and interventionalists, we sought to determine if the use of a leaded arm shield would offer additional protection to the lateral CW and axilla in operators compared with routine leaded aprons.
View Article and Find Full Text PDFBackground: The intensity of radiation scatter that emanates from the X-ray beam during fluoroscopically guided interventions is greater below the fluoroscopy table than above. Yet interventionalists' lower legs are typically unshielded and table skirts are often positioned incorrectly. We sought to characterize the efficacy of the leg protector wraps (Leg Wraps, Burlington Medical Inc.
View Article and Find Full Text PDFBackground: Radiation exposure and imaging quality are among the main concerns in endovascular procedures. The Clear VD11 PURE platform technology system (Siemens Healthineers, Erlangen, Germany) has been reported to lower the radiation dose and improve image quality. In the present study, we evaluated whether the radiation dose during peripheral arterial endovascular procedures had decreased after implementation of this new imaging system.
View Article and Find Full Text PDFObjective: Long-term radiation exposure from fluoroscopically guided interventions (FGIs) can cause cataracts and brain tumors in the operator. We have previously demonstrated that leaded eyewear does not decrease the operator eye radiation dose unless lead shielding has been added to the lateral and inferior portions. Therefore, we have developed a disposable, lightweight, lead-equivalent shield that can be attached to the operator's eyewear that conforms to the face and adheres to the surgical mask.
View Article and Find Full Text PDFObjective: For fenestrated endovascular aneurysm repair (FEVAR), the implementation of the VesselNavigator (Philips Healthcare, Best, The Netherlands) to provide a 3-dimensional vessel roadmap has been shown to reduce patient radiation exposure. Unfortunately, FEVAR radiation doses remain substantial despite utilization of this technology. Traditionally, registration of the live fluoroscopy with the pre-operative CTA is performed via the acquisition of a low-dose cone-beam CT scan.
View Article and Find Full Text PDFPurpose: To present our experience in reducing CT radiation doses in a complex tertiary health system through CT protocol standardization and optimization.
Methods: A CT radiation task force was created to reduce CT protocol heterogeneity and radiation doses. Redundant protocols were eliminated.
Background: Female gender is considered a risk factor for worse perioperative outcomes after fenestrated endovascular aneurysm repair (FEVAR). We hypothesized that women would have more unfavorable anatomy, increasing case complexity and leading to higher radiation doses. Our aim was to evaluate the effect of gender on radiation dose during FEVARs.
View Article and Find Full Text PDFJ Vasc Surg
February 2021
Objective: Fenestrated-branched endovascular aneurysm repair (F/B-EVAR) is a complex procedure that generates high radiation doses. Magnification aids in vessel cannulation but increases radiation. The aim of the study was to compare radiation doses to patients and operating room staff from two fluoroscopy techniques, standard magnification vs dual fluoroscopy with live-image digital zooming during F/B-EVAR.
View Article and Find Full Text PDFObjective: Ocular radiation exposure from fluoroscopically guided interventions (FGIs) can cause cataracts. Standard lead eyewear may not significantly reduce eye radiation dose as the majority of scattered radiation penetrates the operator's eye obliquely. Our aim was to evaluate the efficacy of standard leaded eyewear and a customized eyewear design in lowering eye radiation dose to vascular surgeons.
View Article and Find Full Text PDFPurpose: To compare radiation dose and image quality for abdominal CTs performed on a spectral detector CT (SDCT) and a comparable single-energy conventional CT scanner for patients of different sizes.
Methods: Four semi-anthropomorphic phantoms were scanned on an SDCT (IQon, Philips Healthcare) and a comparable single-energy CT (iCT 256, Philips Healthcare) under matched scan parameters. Image noise and radiation dose were compared.
Introduction: Fenestrated endovascular aneurysm repair (FEVAR) is the highest radiation dose procedure performed by vascular surgeons. We sought to characterize the radiation dose to patients and staff during FEVAR procedures with different premanufactured devices.
Methods: A single-center prospective study of FEVARs was performed over 24 months.
Objective: To analyze the impact of pelvic computed tomography (CT) technique optimization on estimated dose and subjective and objective image quality.
Materials And Methods: An institutional review board (IRB)-approved retrospective records review was performed with waived informed consent. Five CT scanners (various manufacturers/models) were standardized to match the lowest dose profile on campus via subjective assessment of clinical images by experienced musculoskeletal radiologists.
Objective: Radiation to the interventionalist's brain during fluoroscopically guided interventions (FGIs) may increase the incidence of cerebral neoplasms. Lead equivalent surgical caps claim to reduce radiation brain doses by 50% to 95%. We sought to determine the efficacy of the RADPAD (Worldwide Innovations & Technologies, Lenexa, Kan) No Brainer surgical cap (0.
View Article and Find Full Text PDFPurpose: The purpose of this study was to evaluate the quantitative accuracy of spectral images from a detector-based spectral CT scanner using a phantom with iodine-loaded inserts.
Methods: A 40-cm long-body phantom with seven iodine inserts (2-20 mg/ml of iodine) was used in the study. The inserts could be placed at 5.
Background: A new proprietary image-processing system known as AlluraClarity, developed by Philips Healthcare (Best, The Netherlands) for radiation-based interventional procedures, claims to lower radiation dose while preserving image quality using noise-reduction algorithms. This study determined whether the surgeon and patient radiation dose during complex endovascular procedures (CEPs) is decreased after the implementation of this new operating system.
Methods: Radiation dose to operators, procedure type, reference air kerma, kerma area product, and patient body mass index were recorded during CEPs on two Philips Allura FD 20 fluoroscopy systems with and without Clarity.
Purpose: To study the feasibility of using an iterative reconstruction algorithm to improve previously reconstructed CT images which are judged to be non-diagnostic on clinical review. A novel rapidly converging, iterative algorithm (RSEMD) to reduce noise as compared with standard filtered back-projection algorithm has been developed.
Materials And Methods: The RSEMD method was tested on in-silico, Catphan(®)500, and anthropomorphic 4D XCAT phantoms.
Background: Surgeon radiation dose during complex fluoroscopically guided interventions (FGIs) has not been well studied. We sought to characterize radiation exposure to surgeons during FGIs based on procedure type, operator position, level of operator training, upper vs lower body exposure, and addition of protective shielding.
Methods: Optically stimulable, luminescent nanoDot (Landauer, Inc, Glenwood, Ill) detectors were used to measure radiation dose prospectively to surgeons during FGIs.
Background: Endovascular aortic aneurysm repairs (EVARs) with fenestrated (FEVAR) stent grafts are high radiation dose cases, yet no skin injuries were found retrospectively in our 61 cases with a mean peak skin dose (PSD) of 6.8 Gy. We hypothesize that skin injury is under-reported.
View Article and Find Full Text PDFCurr Probl Diagn Radiol
September 2015
Fluoroscopically guided procedures are an area of radiology in which radiation exposure to the patient is highly operator dependent. Modern fluoroscopy machines display a variety of information, including technique factors, field of view, operating geometry, exposure mode, fluoroscopic time, air kerma at the reference point (RAK), and air kerma area-product. However, the presentation of this information is highly vendor specific, and many users are unaware of how to interpret this information and use it to perform a study with the minimum necessary dose.
View Article and Find Full Text PDFBackground: Radiation-induced skin injury is a serious potential complication of fluoroscopically guided interventions. Transient erythema occurs at doses of 2 to 5 Gy, whereas permanent epilation, ulceration, and desquamation are expected at doses above this level. Complex endovascular procedures (CEPs), such as fenestrated endovascular aortic aneurysm repair (FEVAR), are associated with high radiation doses, yet the prevalence of radiation-induced skin injury is unknown.
View Article and Find Full Text PDFObjective: Complex endovascular procedures such as fenestrated endovascular aneurysm repair (FEVAR) are associated with higher radiation doses compared with other fluoroscopically guided interventions (FGIs). The purpose of this study was to determine whether surgeon education on radiation dose control can lead to lower reference air kerma (RAK) and peak skin dose (PSD) levels in high-dose procedures.
Methods: Radiation dose and operating factors were recorded for FGI performed in a hybrid room over a 16-month period.
Rationale And Objectives: To address the risk of radiation injury during interventional procedures, the Joint Commission has defined prolonged fluoroscopy resulting in a cumulative skin dose of 15 Gy or more to a single field as a reviewable sentinel event. The goal of this work is to present a system for identifying potential fluoroscopic sentinel events (FSE) and describing common case characteristics.
Materials And Methods: Criteria based on fluoroscopic time (FT) > 150 minutes and reference air kerma (RAK) > 6 Gy were used to identify potential sentinel events.
Computed tomographic (CT) scanning technology now employs up to 320 detector rows of 0.5-mm width and allows rapid acquisition of isotropic volume datasets over the entire body. Data from a single CT acquisition can be reconstructed into image series that would formerly have required multiple acquisitions.
View Article and Find Full Text PDF