Early detection of CKD using point of care creatinine and eGFR testing improves patient management outcomes. We undertook a field study to evaluate the use of a whole blood creatinine/eGFR device to screen a rural Nicaraguan population to determine the variability between creatinine methods and specimen types. All specimens including capillary and venous dried blood spots (DBS) were tested with an isotope dilution liquid chromatography mass spectrometry (ID-LCMS) gold standard method.
View Article and Find Full Text PDFObjective: To develop a tool to assess the clinical accuracy of glucose meter performance using an insulin dosing protocol to assess the frequency and extent of error in insulin dose categories.
Methods: Retrospective comparison of 1815 glucose meter and central laboratory glucose results obtained from 1698 critically ill patients was conducted using the Parkes error grid, Surveillance error grid and an insulin dose error assessment grid with a sliding scale insulin dosing protocol used to manage critically ill patients.
Results: Parkes error grid and Surveillance error grid analyses indicated little risk conferred with the glucose meter results.
Objectives: New data have emerged from ambulatory and acute care settings about adverse patient events, including death, attributable to erroneous blood glucose meter measurements and leading to questions over their use in critically ill patients. The U.S.
View Article and Find Full Text PDFBackground: Off-meter dosed photometric glucose-oxidase-based glucose meters have been reported to be susceptible to interference by hydrogen-peroxide-based disinfecting agents. The objective of this study was to determine if a single application of hydrogen-peroxide-containing Accel® wipe to disinfect an on-meter dosed amperometric glucose-oxidase-based glucose meter will influence its performance.
Method: The performance of five on-meter dosed amperometric glucose-oxidase-based glucose meters was determined before and after disinfecting the devices with a single application of either CaviWipes® (14.
Background: Although measurement of whole-blood creatinine at the point of care offers rapid assessment of renal function, agreement of point-of-care (POC) results with central laboratory methods continues to be a concern. We assessed the influence of several potential interferents on POC whole-blood creatinine measurements.
Methods: We compared POC creatinine (Nova StatSensor) measurements with plasma enzymatic (Roche Modular) and isotope dilution mass spectrometry (IDMS) assays in 119 hospital inpatients.
Background: Patients and physicians expect accurate whole blood glucose monitoring even when patients are anemic, are undergoing peritoneal dialysis, or have slightly elevated ascorbate levels. The objective of this study was to estimate analytical error in two consumer and two hospital glucose meters contributed by variations in hematocrit, maltose, ascorbate, and imprecision.
Methods: The influence of hematocrit (20-60%), maltose, and ascorbate were tested alone and in combination with each glucose meter and with a reference plasma glucose method at three concentrations of glucose.
Aims/hypothesis: The Andres clamp technique, which requires accurate and timely determination of glucose, utilizes the Beckman or Yellow Springs Instruments (YSI) glucose analyzers. Both instruments require maintenance, a dedicated operator, preparation of a plasma sample, and a duplicate measurement that takes ≥2 minutes. The Nova StatStrip glucose meter was evaluated for accuracy, reliability, and near-real-time availability of glucose.
View Article and Find Full Text PDFObjective: To evaluate the analytical performance of the Nova StatSensor creatinine meter.
Design And Methods: Imprecision, linearity, patient correlation and interference studies were completed.
Results: Total imprecision was 4.
Objectives: To develop and apply a mathematical model of the relationship between hematocrit, meter glucose and reference glucose concentrations as a tool for evaluation of whole blood glucose meters.
Design And Methods: Patient blood gas specimens were used to compare the LifeScan SureStep Flexx and the Nova StatStrip glucose meters with reference results obtained from a Radiometer 725 blood gas analyzer. Linear regression analysis was conducted to determine the extent that patient hematocrit and reference glucose concentrations predicted the performance of the glucose meters.
Diabetes Technol Ther
October 2009
Background: Interference studies of four glucose meters (Nova Biomedical [Waltham, MA] StatStrip [hospital grade], Roche Diagnostics [Indianapolis, IN] Accu-Chek Aviva [home grade], Abbott Diabetes Care [Alameda, CA] Precision FreeStyle Freedom [home grade], and LifeScan [Milpitas, CA] SureStep Flexx [hospital grade]) were evaluated and compared to the clinical laboratory plasma hexokinase reference method (Roche Hitachi 912 chemistry analyzer). These meters were chosen to reflect the continuum of care from hospital to home grade meters commonly seen in North America.
Methods: Within-run precision was determined using a freshly prepared whole blood sample spiked with concentrated glucose to give three glucose concentrations.
Objectives: Glucose meters are widely used in self and hospital monitoring of blood glucose. We examined the analytical performance of a StatStrip glucose monitoring system.
Design And Methods: Linearity, % recovery and within-run imprecision were studied using glucose-spiked whole blood.
J Autom Methods Manag Chem
July 2011
MODULAR ANALYTICS (Roche Diagnostics) (MODULAR ANALYTICS, Elecsys and Cobas Integra are trademarks of a member of the Roche Group) represents a new approach to automation for the clinical chemistry laboratory. It consists of a control unit, a core unit with a bidirectional multitrack rack transportation system, and three distinct kinds of analytical modules: an ISE module, a P800 module (44 photometric tests, throughput of up to 800 tests/h), and a D2400 module (16 photometric tests, throughput up to 2400 tests/h). MODULAR ANALYTICS allows customised configurations for various laboratory workloads.
View Article and Find Full Text PDFBackground: Most glucose meter comparisons to date have focused on performance specifications likely to impact subcutaneous dosing of insulin. We evaluated four hospital-based glucose meter technologies for accuracy, precision, and analytical interferences likely to be encountered in critically ill patients, with the goal of identifying and discriminating glucose meter performance specifications likely to impact intensive intravenous insulin dosing.
Methods: Precision, both within-run and day-to-day, was evaluated on all four glucose meters.
Spontaneous rupture of the spleen is a rare complication of infectious mononucleosis with no clear consensus on appropriate management. Although management of traumatic splenic rupture has largely moved to nonoperative treatment, splenectomy is still frequently used in dealing with rupture of the diseased spleen. Here we report the case of a 16-year-old boy with splenic rupture secondary to laboratory-confirmed infectious mononucleosis in the absence of trauma.
View Article and Find Full Text PDFBackground/purpose: Functional constipation with associated fecal incontinence responds poorly to medical management once megarectum has developed. The authors describe resecting the dilated rectum and inserting a cecostomy button for antegrade enemas in this difficult condition.
Methods: Four children, ages 9 to 15 years, with a history of unremitting constipation and fecal incontinence were referred for evaluation after not responding to medical management.