Publications by authors named "Jeffrey A Leppo"

Although cardiovascular mortality is decreasing over the last two decades, the cost of such care is escalating at a pace that is not sustainable for Medicare. Over this same time period, cardiac imaging has grown at an extremely rapid rate and is a leading contributor to this escalation in expense. It is now incumbent on both profession medical societies and individual physicians to demonstrate that cardiovascular care and the imaging growth lead to better patient outcomes and that the level of competent performance in these areas is documented.

View Article and Find Full Text PDF

Background: Dynamic single photon emission computed tomography (SPECT) acquisition and reconstruction of early poststress technetium 99m teboroxime washout images has been shown to be useful in the detection of coronary disease. Assessment of poststress regional wall motion may offer additional use in assessing coronary disease. Our goal was to investigate the feasibility of simultaneously imaging myocardial ischemia and transient poststress akinesis using gated-dynamic SPECT.

View Article and Find Full Text PDF

Rationale And Objectives: Imaging and estimation of left ventricular function have major diagnostic and prognostic importance in patients with coronary artery disease. It is vital that the method used to estimate cardiac ejection fraction (EF) allows the observer to best perform this task. To measure task-based performance, one must clearly define the task in question, the observer performing the task, and the patient population being imaged.

View Article and Find Full Text PDF

Objectives: Regadenoson, a selective A2A adenosine receptor agonist, was evaluated for tolerability and effectiveness as a pharmacological stress agent for detecting reversible myocardial hypoperfusion when combined with single-photon emission computed tomography (SPECT).

Background: Adenosine and dipyridamole are nonselective adenosine agonists currently used as pharmacologic stressors. Despite proven safety, these agents often cause undesirable side effects and require a continuous infusion.

View Article and Find Full Text PDF

Background: Past receiver operating characteristic (ROC) studies have demonstrated that single photon emission computed tomography (SPECT) perfusion imaging by use of iterative reconstruction with combined compensation for attenuation, scatter, and detector response leads to higher area under the ROC curve (A(z)) values for detection of coronary artery disease (CAD) in comparison to the use of filtered backprojection (FBP) with no compensations. A new ROC study was conducted to investigate whether this improvement still holds for iterative reconstruction when observers have available all of the imaging information normally presented to clinical interpreters when reading FBP SPECT perfusion slices.

Methods And Results: A total of 87 patient studies including 50 patients referred for angiography and 37 patients with a lower than 5% likelihood for CAD were included in the ROC study.

View Article and Find Full Text PDF

Unlabelled: Nonuniform attenuation, scatter, and distance-dependent resolution are confounding factors inherent in SPECT imaging. Iterative reconstruction algorithms permit modeling and compensation of these degradations. We investigated through human-observer receiver-operating-characteristic (ROC) studies which (if any) combination of such compensation strategies best improves the accuracy of detection of coronary artery disease (CAD) when expert readers have only stress images for diagnosis.

View Article and Find Full Text PDF