Fuel chromatography is inherently limited by the high complexity of petroleum fuel compositions. In practice, almost no fuel components are fully resolved in gas chromatography. This is due to both insufficient peak capacity for the large number of individual components within time and chromatographic efficiency constraints, and insufficient resolving power of the stationary phase in the gas chromatography column relative to the many structurally similar isomers or homologs present in petrochemical fuels.
View Article and Find Full Text PDFUnlabelled: The effect of microwave frequency electromagnetic fields on living microorganisms is an active and highly contested area of research. One of the major drawbacks to using mesophilic organisms to study microwave radiation effects is the unavoidable heating of the organism, which has limited the scale (<5 ml) and duration (<1 h) of experiments. However, the negative effects of heating a mesophile can be mitigated by employing thermophiles (organisms able to grow at temperatures of >60°C).
View Article and Find Full Text PDFThe change in custody of fuel shipments at depots, pipelines, and ports could benefit from an analyzer that could rapidly verify that properties are within specifications. To meet this need, the design requirements for a fuel analyzer based on near-infrared (NIR) spectroscopy, such as spectral region and resolution, were examined. It was found that the 1000 to 1600 nm region, containing the second CH overtone and combination vibrational modes of hydrocarbons, provided the best near-infrared to fuel property correlations when path length was taken into account, whereas 4 cm(-1) resolution provided only a modest improvement compared to 16 cm(-1) resolution when four or more latent variables were used.
View Article and Find Full Text PDFA combination surface plasmon resonance (SPR) and conductivity sensor array was developed and implemented to demonstrate the ability to differentiate among changes in dissolved organic carbon (DOC) and salinity in coastal water. The array is capable of achieving sufficient spatial and temporal data density to better understand the cycling and fate of terrestrial DOC in coastal areas. DOC is the second largest source of bioreactive carbon in the environment and plays a key role in mediating microbial activity and generation of atmospheric CO(2).
View Article and Find Full Text PDFDuring the development of automated computational methods to detect minute compositional changes in fuels, it became apparent that peak selection through the spectral deconvolution of gas chromatography-mass spectrometry (GC-MS) data is limited by the complexity and noise levels inherent in the data. Specifically, current techniques are not capable of detecting minute, chemically relevant compositional differences with sufficient sensitivity. Therefore, an alternative peak selection strategy was developed based on spectral interpretation through interval-oriented parallel factor analysis (PARAFAC).
View Article and Find Full Text PDFPurpose: To investigate the pharmacodynamic behaviour of the selective cyclooxygenase-2 inhibitor, lumiracoxib, in the rat air pouch.
Methods: Air pouches were injected with lipopolysaccharide to stimulate prostaglandin E2 (PGE2) production 1h after lumiracoxib treatment. Pouch fluid samples were collected 6 or 24 h after lumiracoxib administration to measure PGE2 levels.
Antimicrob Agents Chemother
September 2002
Peptide deformylase (PDF) is a prokaryotic metalloenzyme that is essential for bacterial growth and is a new target for the development of antibacterial agents. All previously reported PDF inhibitors with sufficient antibacterial activity share the structural feature of a 2-substituted alkanoyl at the P(1)' site. Using a combination of iterative parallel synthesis and traditional medicinal chemistry, we have identified a new class of PDF inhibitors with N-alkyl urea at the P(1)' site.
View Article and Find Full Text PDF