Background And Aims: Prophylactic implantable cardioverter-defibrillators (ICDs) are not recommended until left ventricular ejection fraction (LVEF) has been reassessed 40 to 90 days after an acute myocardial infarction. In the current therapeutic era, the prognosis of sustained ventricular arrhythmias (VAs) occurring during this early post-infarction phase (i.e.
View Article and Find Full Text PDF(1) Background: Receiving the first internal electric shock is a turning point for patients with an implantable cardioverter defibrillator (ICD) for primary prevention. However, no study has investigated whether patients who receive a first device-delivered electric shock have a poor prognosis even at the time of ICD implantation. (2) Methods: We retrospectively identified 55 patients with ischemic (n = 31) or dilated (n = 24) cardiomyopathy who underwent ICD implantation for primary prevention with exercise test at the time of implantation.
View Article and Find Full Text PDFManagement of left-sided accessory pathways (APs) is based on catheter ablation through an antegrade or retrograde approach. Both are safe and effective but are associated with exposure to x-rays; however, recipients of ablation are generally young. We sought to evaluate the impact of the approach chosen on dose-area product (DAP).
View Article and Find Full Text PDFJ Interv Card Electrophysiol
August 2019
Purpose: Cardiologists are among the health professionals that are most exposed to ionizing radiation, but there is no study comparing the level of exposure of physicians during different electrophysiology procedures. We aimed to measure and compare cardiologists' exposure to radiation during different electrophysiology procedures.
Methods: The study population comprised all electrophysiology procedures performed over a 6-month period in a large referral centre.
Cardiologists are among the health professionals that are most exposed to ionizing radiation, but there is no recent study quantifying overexposure of physicians during cardiac resynchronisation therapy (CRT) procedures compared to 'classical' implantation of pacemakers (PMs) or implantable cardioverter-defibrillators (ICDs). We aimed to measure and compare operator exposure to radiation during implantation of PM and ICD with or without CRT. The study population comprised all PMs and ICDs implanted in a large referral centre over a six months period.
View Article and Find Full Text PDFAims: The increased use of implantable cardiac devices has been accompanied by an increase in infection. However, risk factors for infection of implanted devices are poorly documented. We aimed to identify risk factors in patients with long-term follow-up after implantation of cardiac devices.
View Article and Find Full Text PDF