Cardiac arrhythmias are a leading cause of mortality worldwide. Wearable devices based on photoplethysmography give the opportunity to screen large populations, hence allowing for an earlier detection of pathological rhythms that might reduce the risks of complications and medical costs. While most of beat detection algorithms have been evaluated on normal sinus rhythm or atrial fibrillation recordings, the performance of these algorithms in patients with other cardiac arrhythmias, such as ventricular tachycardia or bigeminy, remain unknown to date.
View Article and Find Full Text PDFBackground: Superimposition of farfield (FF) and nearfield (NF) bipolar voltage electrograms (BVE) complicates the confirmation of pulmonary vein (PV) isolation after catheter ablation of atrial fibrillation. Our aim was to develop an automatic algorithm based on a single-beat analysis to discriminate PV NF from atrial FF BVE from a circular mapping catheter during the cryoballoon PV isolation.
Methods: During freezing cycles in cryoablation PVI, local NF and distant FF signals were recorded, identified and labelled.
Signal processing tools are required to efficiently analyze data collected in body-surface-potential map (BSPM) recordings. A limited number of such tools exist for studying persistent atrial fibrillation (persAF). We propose two novel, spatiotemporal indices for processing BSPM data and test their clinical applicability through a comparison with the recently proposed non-dipolar component index (NDI) for prediction of single-procedure catheter ablation (CA) success rate in persAF patients.
View Article and Find Full Text PDFSpectral analysis of atrial signals has been used to identify regions of interest in atrial fibrillation (AF). However, the relationship to the atrial substrate is unclear. In this study, we compare regions with dominant frequency (DF), simultaneously determined in the left atrium (LA) by a novel noncontact mapping system using unipolar charge density signals, to the zones of slow conduction (SZ) during AF.
View Article and Find Full Text PDFBackground And Objective: The automated detection of atrial activations (AAs) recorded from intracardiac electrograms (IEGMs) during atrial fibrillation (AF) is challenging considering their various amplitudes, morphologies and cycle length. Activation time estimation is further complicated by the constant changes in the IEGM active zones in complex and/or fractionated signals. We propose a new method which provides reliable automatic extraction of intracardiac AAs recorded within the pulmonary veins during AF and an accurate estimation of their local activation times.
View Article and Find Full Text PDFEasy-to-use and accurate heart rate variability (HRV) assessments are essential in athletes' follow-up, but artifacts may lead to erroneous analysis. Artifact detection and correction are the purpose of extensive literature and implemented in dedicated analysis programs. However, the effects of number and/or magnitude of artifacts on various time- or frequency-domain parameters remain unclear.
View Article and Find Full Text PDFThe role of dominant frequency (DF) in tracking the efficiency of a stepwise catheter ablation (step-CA) in persistent atrial fibrillation (peAF) remains poorly studied. We hypothesized that the DF time-course during step-CA displays divergent patterns between patients in whom a step-CA successfully restores long-term sinus rhythm (SR) and those with recurrence. This study involved 40 consecutive patients who underwent a step-CA for peAF (sustained duration 19 ± 11 months).
View Article and Find Full Text PDFRecent advances in wearable technologies integrating multi-modal sensors have enabled the in-field monitoring of several physiological metrics. In sport applications, wearable devices have been widely used to improve performance while minimizing the risk of injuries and illness. The objective of this project is to estimate breathing rate (BR) from respiratory sinus arrhythmia (RSA) using heart rate (HR) recorded with a chest belt during physical activities, yielding additional physiological insight without the need of an additional sensor.
View Article and Find Full Text PDFSilent brain infarcts (SBI) are frequently detected in patients with atrial fibrillation (AF), but it is unknown whether SBI are linked to autonomic dysfunction. We aimed to explore the association of autonomic dysfunction with SBI in AF patients. 1,358 AF patients without prior stroke or TIA underwent brain MRI and 5-min resting ECG.
View Article and Find Full Text PDFConsistently successful patient outcomes following catheter ablation (CA) for treatment of persistent atrial fibrillation (pers-AF) remain elusive. We propose an electrocardiogram (ECG) analysis designed to (1) refine selection of patients most likely to benefit from ablation, and (2) examine the temporal evolution of AF organization indices that could act as clinical indicators of ongoing ablation effectiveness and completeness. Twelve-lead ECG was continuously recorded in 40 patients (61 ± 8 years) during stepwise CA (step-CA) procedures for treatment of pers-AF (sustained duration 19 ± 11 months).
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2020
Atrial fibrillation (AF) affects millions of people worldwide and needs to be diagnosed in its early stage to provide proper treatment. However, the numerous wearable devices available today are not yet able to discriminate AF episodes from other cardiac arrhythmias and merely detect normal vs abnormal rhythms.In this study we investigated the performance of a traditional classifier - designed to distinguish AF and sinus rhythm (SR) using inter-beat intervals (IBI) - when confronted with other - non-AF - arrhythmias.
View Article and Find Full Text PDFBackground Impaired heart rate variability (HRV) is associated with increased mortality in sinus rhythm. However, HRV has not been systematically assessed in patients with atrial fibrillation (AF). We hypothesized that parameters of HRV may be predictive of cardiovascular death in patients with AF.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2019
Wearable devices are an unobtrusive, cost-effective means of continuous ambulatory monitoring of chronic cardiovascular diseases. However, on these resource-constrained systems, electrocardiogram (ECG) processing algorithms must consume minimal power and memory, yet robustly provide accurate physiological information. This work presents REWARD, the Relative-Energy-based WeArable R-Peak Detection algorithm, which is a novel ECG R-peak detection mechanism based on a nonlinear filtering method called Relative-Energy (Rel-En).
View Article and Find Full Text PDFIntroduction: Baroreflex sensitivity (BRS) is essential to ensure rapid adjustment to variations in blood pressure (BP). Spontaneous baroreflex function can be assessed using continuous recordings of blood pressure. The goal of this study was to compare four methods for BRS quantification [the sequence, Bernardi's (BER), frequency and transfer function methods] to identify the most consistent method across an extreme range of conditions: rest and exercise, in normoxia, hypoxia, hypocapnia, and hypercapnia.
View Article and Find Full Text PDFBackground: High values of ECG and intracardiac dominant frequency (DF) are indicative of significant atrial remodeling in persistent atrial fibrillation (peAF). We hypothesized that patients with peAF unresponsive to ablation display higher ECG and intracardiac DFs than those remaining in sinus rhythm (SR) on the long term.
Methods: Forty consecutive patients underwent stepwise ablation for peAF (sustained duration 19 ± 11 months).
This study aims at evaluating the potential of a wrist-type photoplethysmographic (PPG) device to discriminate between atrial fibrillation (AF) and other types of rhythm. Data from 17 patients undergoing catheter ablation of various arrhythmias were processed. ECGs were used as ground truth and annotated for the following types of rhythm: sinus rhythm (SR), AF, and ventricular arrhythmias (VA).
View Article and Find Full Text PDFBaroreflex sensitivity (BRS) is essential to ensure rapid adjustment to variations in blood pressure (BP). Little is known concerning the adaptive responses of BRS during acclimatization to high altitude at rest and during exercise. Twenty-one healthy sea-level residents were tested near sea level (SL, 130 m), the 1st (ALT1) and 16th day (ALT16) at 5,260 m using radial artery catheterization.
View Article and Find Full Text PDFAnti-gravity treadmills facilitate locomotion by lower-body positive pressure (LBPP). Effects on cardiorespiratory regulation are unknown. Healthy men (30 ± 8 y, 178.
View Article and Find Full Text PDFObjectives: Heart rate variability (HRV) is commonly used to diagnose overreaching and monitor athletes' responses to training. Baroreflex sensitivity (BRS) is modified by changes in training load and might be another means to detect overreaching. The goal of this study was to assess BRS and HRV changes in two groups of athletes responding either negatively (FOR) or positively (AF) to similar training overload.
View Article and Find Full Text PDFObjectives: The electrocardiogram (ECG) of patients with BrS in sinus rhythm might reflect intrinsic atrial electrical abnormalities independent from any previous atrial fibrillation (AF). Aim of this study is to investigate the presence of P-wave abnormalities in patients with BrS and no history of AF, and to compare them with those displayed by patients with documented paroxysmal AF and by healthy subjects.
Methods: Continuous 5-min 16-lead ECG recordings in sinus rhythm were obtained from 72 participants: 32 patients with a type 1 Brugada ECG, 20 patients with a history of paroxysmal AF and 20 age-matched healthy subjects.
Normobaric hypoxia (NH) is used as a surrogate for hypobaric hypoxia (HH). Recent studies reported physiological differences between NH and HH. Baroreflex sensitivity (BRS) decreases at altitude or following intense training.
View Article and Find Full Text PDFHeart rate variability (HRV) is non-invasive and commonly used for monitoring responses to training loads, fitness, or overreaching in athletes. Yet, the recording duration for a series of RR-intervals varies from 1 to 15 min in the literature. The aim of the present work was to assess the minimum record duration to obtain reliable HRV results.
View Article and Find Full Text PDFIEEE Trans Biomed Eng
April 2018
In this paper, we propose a fast novel nonlinear filtering method named Relative-Energy (Rel-En), for robust short-term event extraction from biomedical signals. We developed an algorithm that extracts short- and long-term energies in a signal and provides a coefficient vector with which the signal is multiplied, heightening events of interest. This algorithm is thoroughly assessed on benchmark datasets in three different biomedical applications, namely ECG QRS-complex detection, EEG K-complex detection, and imaging photoplethysmography (iPPG) peak detection.
View Article and Find Full Text PDFPhotoplethysmographic (PPG) signals are easily corrupted by motion artifacts when the subjects perform physical exercise. This paper introduces a two-step processing scheme to estimate heart rate (HR) from wrist-type PPG signals strongly corrupted by motion artifacts. Adaptive noise cancellation, using normalized least-mean-square algorithm, is first performed to attenuate motion artifacts and reconstruct multiple PPG waveforms from different combinations of corrupted PPG waveforms and accelerometer data.
View Article and Find Full Text PDFFew data are available on the assessment of P-wave beat-to-beat morphology variability and its ability to identify patients prone to paroxysmal atrial fibrillation (AF) occurrence. Aim of this study was to determine whether electrocardiographic (ECG) parameters resulting from the beat-to-beat analysis of P wave in ECG recorded during sinus rhythm could be indicators of paroxysmal AF susceptibility. ECGs of 76 consecutive patients including 36 patients with history of AF and no overt structural cardiac abnormalities and a control group of 40 healthy patients without history of AF were analyzed.
View Article and Find Full Text PDF