Publications by authors named "Jean Summerton"

Phosphoryl transfer reactions figure prominently in energy metabolism, signaling, transport and motility. Prior detailed studies of selected systems have highlighted mechanistic features that distinguish different phosphoryl transfer enzymes. Here, a top-down approach is developed for comparing statistically the active site configurations between populations of diverse structures in the Protein Data Bank, and it reveals patterns of hydrogen bonding that transcend enzyme families.

View Article and Find Full Text PDF

Density functional theory and natural bond orbital analysis are used to explore the impact of solvent on hyperconjugation in methyl triphosphate, a model for "energy rich" phosphoanhydride bonds, such as found in ATP. As expected, dihedral rotation of a hydroxyl group vicinal to the phosphoanhydride bond reveals that the conformational dependence of the anomeric effect involves modulation of the orbital overlap between the donor and acceptor orbitals. However, a conformational independence was observed in the rotation of a solvent hydrogen bond.

View Article and Find Full Text PDF

Objective(s): To determine if mishandling prior to testing would make a sample from a chronically infected subject appear recently infected when tested by cross-sectional HIV incidence assays.

Methods: Serum samples from 31 subjects with chronic HIV infection were tested. Samples were subjected to different handling conditions, including incubation at 4 °C, 25 °C and 37 °C, for 1, 3, 7 or 15 days prior to testing.

View Article and Find Full Text PDF

Two hundred seventy-nine serum samples from men attending sexually transmitted disease (STD) clinics in Baltimore, Maryland, were tested for herpes simplex virus type 2 (HSV-2)-specific antibody by three immunosorbent glycoprotein G-2-based assays (the Kalon, Focus, and Biokit assays). The results for all samples with positive results were confirmed by Western blotting (91/279; 32.6% HSV-2 seroprevalence).

View Article and Find Full Text PDF

Objective: To evaluate the EasyCD4 assay, a less expensive method to enumerate CD4+ lymphocytes, in resource-limited settings.

Design: Cross-sectional study conducted in the United States and Uganda.

Methods: We compared CD4+ cell counts obtained on replicate samples from HIV-infected patients by the EasyCD4 assay, a microcapillary flow-based system, and by standard flow cytometry or FACSCount with linear regression and the Bland-Altman method.

View Article and Find Full Text PDF