Publications by authors named "Jean Noel Hyacinthe"

Xe dissolution dynamic nuclear polarization (DNP) is a controversial topic. The gold standard technique for hyperpolarized xenon magnetic resonance imaging (MRI) is spin exchange optical pumping, which received FDA approval in 2022. Nevertheless, the versatility of DNP for enhancing the signal of any NMR active nucleus might provide new perspectives for hyperpolarized Xe NMR/MRI.

View Article and Find Full Text PDF

Hyperpolarization of C by dissolution dynamic nuclear polarization (dDNP) boosts the sensitivity of magnetic resonance spectroscopy (MRS), making possible the monitoring and in real time of the biochemical reactions of exogenously infused C-labeled metabolic tracers. The preparation of a hyperpolarized substrate requires the use of free radicals as polarizing agents. Although added at very low doses, these radicals are not biologically inert.

View Article and Find Full Text PDF

Low throughput is one of dissolution Dynamic Nuclear Polarization (dDNP) main shortcomings. Especially for clinical and preclinical applications, where direct C nuclei polarization is usually pursued, it takes hours to generate one single hyperpolarized (HP) sample. Being able to hyperpolarize more samples at once represents a clear advantage and can expand the range and complexity of the applications.

View Article and Find Full Text PDF

Dissolution Dynamic Nuclear Polarization (dDNP) was invented almost twenty years ago. Ever since, hardware advancement has observed 2 trends: the quest for DNP at higher field and, more recently, the development of cryogen free polarizers. Despite the DNP community is slowly migrating towards "dry" systems, many "wet" polarizers are still in use.

View Article and Find Full Text PDF

Cerebral metabolism, which can be monitored by magnetic resonance spectroscopy (MRS), changes rapidly after brain ischaemic injury. Hyperpolarisation techniques boost C MRS sensitivity by several orders of magnitude, thereby enabling in vivo monitoring of biochemical transformations of hyperpolarised (HP) C-labelled precursors with a time resolution of seconds. The exogenous administration of the metabolite L-lactate was shown to decrease lesion size and ameliorate neurological outcome in preclinical studies in rodent stroke models, as well as influencing brain metabolism in clinical pilot studies of acute brain injury patients.

View Article and Find Full Text PDF

The purpose of this study was to develop micron-sized droplet emulsions able to increase the heat deposition of high intensity focused ultrasound (HIFU), aiming to accelerate the tumour ablation in highly perfused organs with reduced side effects. The investigated droplets consisted of a perfluorooctyl bromide (PFOB) core coated with a biocompatible fluorinated surfactant called F-TAC. The novelty of this work relies on the use, for this application, of a high boiling point perfluorocarbon core (142 °C), combined with an in-house fluorinated surfactant to formulate the emulsion, yielding quasi-reversible strong interactions between the HIFU beam and the droplets.

View Article and Find Full Text PDF

Objective: Perfluorocarbon nano- and micron-sized emulsions are a new field of investigation in cancer treatment due to their ability to be used as imaging contrast agents, or as delivery vectors for pharmaceuticals. They also demonstrated capability to enhance the efficiency of high intensity focused ultrasound thermo-therapy. In the context of new biomedical applications we investigated perfluorooctyl bromide (PFOB) theranostic droplets using F NMR.

View Article and Find Full Text PDF

Purpose: Treatments using high-intensity focused ultrasound (HIFU) in the abdominal region remain challenging as a result of respiratory organ motion. A novel method is described here to achieve 3D motion-compensated ultrasound (US) MR-guided HIFU therapy using simultaneous ultrasound and MRI.

Methods: A truly hybrid US-MR-guided HIFU method was used to plan and control the treatment.

View Article and Find Full Text PDF

A fast positioning method for brain tumor microbeam irradiations for preclinical studies at third-generation X-ray sources is described. The three-dimensional alignment of the animals relative to the X-ray beam was based on the X-ray tomography multi-slices after iodine infusion. This method used pink-beam imaging produced by the ID17 wiggler.

View Article and Find Full Text PDF

Given their high sensitivity and ability to limit the field of view (FOV), surface coils are often used in magnetic resonance spectroscopy (MRS) and imaging (MRI). A major downside of surface coils is their inherent radiofrequency (RF) B1 heterogeneity across the FOV, decreasing with increasing distance from the coil and giving rise to image distortions due to non-uniform spatial responses. A robust way to compensate for B1 inhomogeneities is to employ adiabatic inversion pulses, yet these are not well adapted to all imaging sequences - including to single-shot approaches like echo planar imaging (EPI).

View Article and Find Full Text PDF

Hyperpolarized substrates prepared via dissolution dynamic nuclear polarization have been proposed as magnetic resonance imaging (MRI) agents for cancer or cardiac failure diagnosis and therapy monitoring through the detection of metabolic impairments in vivo. The use of potentially toxic persistent radicals to hyperpolarize substrates was hitherto required. We demonstrate that by shining UV light for an hour on a frozen pure endogenous substance, namely the glucose metabolic product pyruvic acid, it is possible to generate a concentration of photo-induced radicals that is large enough to highly enhance the (13)C polarization of the substance via dynamic nuclear polarization.

View Article and Find Full Text PDF

Human bone blood flow, mean blood speed and the number of moving red blood cells were assessed (in arbitrary units), as a function of time, during one cardiac cycle. The measurements were obtained non-invasively on five volunteers by laser-Doppler flowmetry at large interoptode spacing. The investigated bones included: patella, clavicle, tibial diaphysis and tibial malleolus.

View Article and Find Full Text PDF

Using a small, but very instructive experiment, it is demonstrated that laser-Doppler flowmetry (LDF) at large interoptode spacing represents a unique tool for new investigations of thermoregulatory processes modulating the blood flow of small muscle masses in humans. It is shown on five healthy subjects that steady-state values of blood flow (perfusion) in the thenar eminence muscle group depend in a complex manner on both the local intramuscular temperature and local skin temperature, while the values of blood flow parameters measured during physiological transients, such as the post-ischaemic hyperhaemic response, depend only on the intramuscular temperature. In addition, it is shown that the so-called biological zero (i.

View Article and Find Full Text PDF

Background: To define the relationship between regional coronary vasodilator capacity and myocardial circumferential strain at rest in normal weight, overweight, and obese individuals with normal global left-ventricular function.

Methods And Results: Myocardial blood flow at rest and during pharmacologic vasodilation was measured with (13)N-ammonia PET/CT in mL/g/minute in normal weight control (CON, n = 12), overweight (OW, n = 10), and obese individuals (OB, n = 10). In addition, resting myocardial function was evaluated as circumferential strain (Єc, %) by MRI.

View Article and Find Full Text PDF

MR acoustic radiation force imaging (ARFI) is an elegant adjunct to MR-guided high intensity focused ultrasound for treatment planning and optimization, permitting in situ assessment of the focusing and targeting quality. The thermal effect of high intensity focused ultrasound pulses associated with ARFI measurements is recommended to be monitored on line, in particular when the beam crosses highly absorbent structures or interfaces (e.g.

View Article and Find Full Text PDF

Accurate assessment of mice cardiac function with magnetic resonance imaging is essential for longitudinal studies and for drug development related to cardiovascular diseases. Whereas dedicated small animal MR scanners are not readily available, it would be a great advantage to be able to perform cardiac assessment on clinical systems, in particular, in the context of translational research. However, mouse imaging remains challenging since it requires both high spatial and temporal resolutions, while gradient performances of clinical scanners often limit the reachable parameters.

View Article and Find Full Text PDF

Manganese (Mn(2+)) is considered as a specific MRI contrast agent that enters viable cardiomyocytes through calcium pathways. Compared to extracellular gadolinium based contrast agents, it has the potential to assess cell viability. To date, only information from the washout phase after recirculation has been used for the detection and characterization of myocardial infarct.

View Article and Find Full Text PDF

Spiral acquisition schemes offer unique advantages such as flow compensation, efficient k-space sampling and robustness against motion that make this option a viable choice among other non-Cartesian sampling schemes. For this reason, the main applications of spiral imaging lie in dynamic magnetic resonance imaging such as cardiac imaging and functional brain imaging. However, these advantages are counterbalanced by practical difficulties that render spiral imaging quite challenging.

View Article and Find Full Text PDF

Manganese (Mn(2+)) was recognized early as an efficient intracellular MR contrast agent to assess cardiomyocyte viability. It had previously been used for the assessment of myocardial infarction in various animal models from pig to mouse. However, whether Manganese-Enhanced MRI (MEMRI) is also able to assess infarction in the acute phase of a coronary occlusion reperfusion model in mice has not yet been demonstrated.

View Article and Find Full Text PDF

Aims: To evaluate the feasibility of loading resting monocytes/macrophages by intravenous (i.v.) injection of fluorescent iron oxide nanoparticles prior to injury and tracking of these cells in the very same animal to myocardial infarction (MI) by magnetic resonance imaging (MRI) and optical imaging.

View Article and Find Full Text PDF

Real-time cardiac MRI appears as a promising technique to evaluate the mechanical function of the heart. However, ultra-fast MRI acquisitions come with an important signal-to-noise ratio (SNR) penalty, which drastically reduces the image quality. Hence, a real-time denoising approach would be desirable for SNR amelioration.

View Article and Find Full Text PDF

Background: The purpose of this study was to measure regional contractile function in the normal rat using cardiac cine and tagged cardiovascular magnetic resonance (CMR) during incremental low doses of dobutamine and at rest.

Methods: Five rats were investigated for invasive left ventricle pressure measurements and five additional rats were imaged on a clinical 1.5 T MR system using a cine sequence (11-20 phases per cycle, 0.

View Article and Find Full Text PDF

The purpose of this study was to assess the feasibility of cardiac magnetic resonance (MR) tagging in rats on a standard clinical 1.5T MR system. Small animal models have been largely used as an experimental model in cardiovascular disease studies but mainly on high field systems (>4T) dedicated to research.

View Article and Find Full Text PDF

The purposes of this study were to assess the extent of the inflow effect on signal intensity (SI) for fast gradient-recalled-echo (GRE) sequences used to observe first-pass perfusion, and to develop and validate a correction method for this effect. A phantom experiment with a flow apparatus was performed to determine SI as a function of Gd-DTPA concentration for various velocities. Subsequently a flow-sensitive calibration method was developed, and validated on bolus injections into an open-circuit flow apparatus and in vivo.

View Article and Find Full Text PDF