IEEE Trans Ultrason Ferroelectr Freq Control
August 2024
IEEE Trans Ultrason Ferroelectr Freq Control
February 2024
With the development of promising cavitation-based treatments, the interest in cavitation monitoring with passive acoustic mapping (PAM) is significantly increasing. While most of studies regarding PAM are performed in 2-D, 3-D imaging modalities are getting more attention relying on either custom-made or commercial matrix probes. Unless specific phased-arrays are used for a specific application, limitations due to probe apertures often results in poor performances of the 3-D mapping, due to the use of a delay-and-sum (DAS) classic beamformer, which results in strong artifacts and large main lobe sizes.
View Article and Find Full Text PDFPurpose: Several studies have evaluated the interest of Low Intensity Pulsed Ultrasound (LIPUS) in the osseointegration of dental implants in murine or rabbit models. However, the thinness and narrowness bones make it difficult to study the effect of LIPUS. The purpose of this study is to assess the ability of LIPUS to stimulate bone formation in contact with a titanium dental implant in a porcine model.
View Article and Find Full Text PDFSteady and pulsatile aortic stenotic flows through stenosis tubes were experimentally and numerically investigated. The objective was the understanding of the fluid dynamics in arterial geometries most relevant in the context of atherosclerosis. Axisymmetric phantoms corresponding to significant artery stenosis of 50% in diameter and severe aortic stenosis of 75% were respectively machined from silicon.
View Article and Find Full Text PDFIntroduction: Numerous studies have shown the ability of low-energy acoustic waves such as focused ultrasound or shockwave to transiently open blood-brain barrier (BBB) and facilitate drug delivery to the brain. Preclinical and clinical evidences have well demonstrated the efficacy and safety in treating various brain disorders. However, the molecular mechanisms of acoustic waves on the BBB are still not fully understood.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
April 2021
Passive ultrasound imaging is of great interest for cavitation monitoring. Spatiotemporal monitoring of cavitation bubbles in therapeutic applications is possible using an ultrasound imaging probe to passively receive the acoustic signals from the bubbles. Fourier-domain (FD) beamformers have been proposed to process the signals received into maps of the spatial localization of cavitation activity, with reduced computing times with respect to the time-domain approach, and to take advantage of frequency selectivity for cavitation regime characterization.
View Article and Find Full Text PDFWhen excited at sufficiently high acoustic pressures, a wall-attached bubble may exhibit asymmetric nonspherical modes. These vibration modes can be decomposed over the set of spherical harmonics Y_{nm}(θ,ϕ) for a degree n and order m. We experimentally capture the time-resolved dynamics of asymmetric bubble oscillations in a top-view configuration.
View Article and Find Full Text PDFPurpose: Many studies have shown the ability of low intensity pulsed ultrasound (LIPUS) to stimulate the bone, cartilage and tendon regeneration but only a few studied LIPUS interest in the regeneration of the oral mucosa. The purpose of this study is to assess the ability of LIPUS to stimulate the regeneration of the palatal mucosa in a porcine model.
Methods: Ten adults mini-pigs were used.
IEEE Trans Ultrason Ferroelectr Freq Control
December 2018
Ultrasound (US) cavitation is currently being explored for low-invasive therapy techniques applied to a wide panel of pathologies. Because of the random behavior of cavitation, a real-time spatial monitoring system may be required. For this purpose, the US passive imaging techniques have been recently investigated.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
May 2018
Focused transducers composed of flat piezoelectric ceramic coupled with an acoustic lens present an economical alternative to curved piezoelectric ceramics and are already in use in a variety of fields. Using a displacement/pressure (u/p) mixed finite element formulation combined with parametric level-set functions to implicitly define the boundaries between the materials and the fluid-structure interface, a method to optimize the shape of acoustic lens made of either one or multiple materials is presented. From that method, two 400 kHz focused transducers using acoustic lens were designed and built with different rapid prototyping methods, one of them made with a combination of two materials, and experimental measurements of the pressure field around the focal point are in good agreement with the presented model.
View Article and Find Full Text PDFIn the aim of limiting the destructive effects of collapsing bubbles, the regime of stable cavitation activity is currently targeted for sensitive therapeutic applications such as blood-brain barrier opening by ultrasound. This activity is quantified through the emergence of the subharmonic component of the fundamental frequency. Due to the intrinsically stochastic behavior of the cavitation phenomenon, a better control of the different (stable or inertial) cavitation regimes is a key requirement in the understanding of the mechanisms involving each bubble-induced mechanical effect.
View Article and Find Full Text PDFAmongst the variety of complex phenomena encountered in nonlinear physics, a hysteretic effect can be expected on ultrasound cavitation due to the intrinsic nonlinearity of bubble dynamics. When applying successive ultrasound shots for increasing and decreasing acoustic intensities, a hysteretic behaviour is experimentally observed on inertial cavitation activity, with a loop area sensitive to the inertial cavitation threshold. To get a better insight of the phenomena underlying this hysteretic effect, the evolution of the bubble size distribution is studied numerically by implementing rectified diffusion, fragmentation process, rising and dissolution of bubbles from an initial bubble size distribution.
View Article and Find Full Text PDFIn the context of sonoporation, we use supported lipid bilayers as a model for biological membranes and investigate the interactions between the bilayer and microbubbles induced by ultrasound. Among the various types of damage caused by bubbles on the surface, our experiments exhibit a singular dynamic interaction process where bubbles are jumping on the bilayer, forming a necklace pattern of alteration on the membrane. This phenomenon was explored with different time and space resolutions and, based on our observations, we propose a model for a microbubble subjected to the combined action of van der Waals, acoustic and hydrodynamic forces.
View Article and Find Full Text PDFA sonoporation device dedicated to the adherent cell monolayer has been implemented with a regulation process allowing the real-time monitoring and control of inertial cavitation activity. Use of the cavitation-regulated device revealed first that adherent cell sonoporation efficiency is related to inertial cavitation activity, without inducing additional cell mortality. Reproducibility is enhanced for the highest sonoporation rates (up to 17%); sonoporation efficiency can reach 26% when advantage is taken of the standing wave acoustic configuration by applying a frequency sweep with ultrasound frequency tuned to the modal acoustic modes of the cavity.
View Article and Find Full Text PDFIt is well known that acoustic cavitation can facilitate the inward transport of genetic materials across cell membranes (sonoporation). However, partially due to the unstationary behavior of the initiation and leveling of cavitation, the sonoporation effect is usually unstable, especially in low intensity conditions. A system which is able to regulate the cavitation level during sonication by modulating the applied acoustic intensity with a feedback loop is implemented and its effect on in vitro gene transfection is tested.
View Article and Find Full Text PDFPhys Rev E Stat Nonlin Soft Matter Phys
September 2013
Acoustic cavitation-induced microbubbles in a cylindrical resonator filled with water tend to concentrate into ring patterns due to the cylindrical geometry of the system. The shape of these ring patterns is directly linked to the Bjerknes force distribution in the resonator. Experimental observations showed that cavitation bubbles located in the vicinity of this ring may exhibit a spiraling behavior around the pressure nodal line.
View Article and Find Full Text PDFOwing to the complex behavior of ultrasound-induced bubble clouds (nucleation, linear and nonlinear oscillations, collapse), acoustic cavitation remains a hardly controllable phenomenon, leading to poorly reproducible ultrasound-based therapies. A better control of the various aspects of cavitation phenomena for in vivo applications is a key requirement to improve emerging ultrasound therapies. Previous publications have reported on systems performing regulation of acoustic cavitation in continuous sonication when applied in vitro, but the main challenge today is to achieve real-time control of cavitation activity in pulsed sonication when used in vivo.
View Article and Find Full Text PDFApplications involving acoustic cavitation mechanisms, such as sonoporation, are often poorly reproducible because of the unstationary behavior of cavitation. For this purpose, this study proposes to work at a fixed cavitation level instead of a fixed acoustic intensity. A regulated cavitation generator has been developed in an in vitro configuration of standing wave field.
View Article and Find Full Text PDFEnhancing cavitation activity with minimal acoustic intensities could be interesting in a variety of therapeutic applications where mechanical effects of cavitation are needed with minimal heating of surrounding tissues. The present work focuses on the relative efficiency of a signal combining two neighbouring frequencies and a one-frequency signal for initiating ultrasound inertial cavitation. Experiments were carried out in a water tank, using a 550kHz piezoelectric composite spherical transducer focused on targets with 46μm roughness.
View Article and Find Full Text PDFSonoporation holds many promises in developing an efficient, reproducible and permanent gene delivery vector. In this study, we evaluated sonoporation as a method to transfect nucleic acids in suspension cells, including the human follicular lymphoma cell line RL and fresh human Chronic Lymphocytic Leukemia (CLL) cells. RL and CLL cells were exposed to continuous ultrasound waves (445 kHz) in the presence of either plasmid DNA coding for green fluorescent protein (GFP) or fluorescent siRNA directed against BCL2L1.
View Article and Find Full Text PDFUltrasound treatment has been proposed by several authors to enhance the repair of long bone injury. The present study investigated in a murine model the treatment by low-intensity pulsed ultrasound (LIPUS) of calvarial flat bone defect. The animals were operated to create bone defect and exposed to ultrasound for 5 min per day, 5 d per week, during two weeks.