Publications by authors named "Jay Budrewicz"

Article Synopsis
  • The study aimed to understand how different pressures in the renal pelvis during ureteroscopy affect the likelihood of infection using a pig model.
  • Researchers performed ureteroscopy on pigs while controlling the renal pelvis pressure at either 37 mmHg or 75 mmHg and infused saline with or without E. coli to track infection rates and inflammatory responses.
  • Results showed that higher pressure (75 mmHg) combined with E. coli irrigation led to significant increases in inflammatory markers and bacteraemia, compared to lower pressure and saline alone.
View Article and Find Full Text PDF

Autologous tissues such as buccal mucosa (BM) are widely used for reconstruction of urethral strictures; however, limitations such as donor site morbidity and scarce tissue supply require the development of alternative biomaterials for urethral repair. The goals of this study were to determine the safety and efficacy of bi-layer silk fibroin (BLSF) matrices for urethral stricture repair and compare histological and functional outcomes to the standard approach, BM urethroplasty under good laboratory practices. A total of 13 rabbits exhibiting urethral stricture formation following electrocoagulation injury were treated with onlay urethroplasty with either acellular BLSF (N = 7) or autologous BM (N = 6) grafts for 3 months.

View Article and Find Full Text PDF

Objective: To evaluate the relationship between renal pelvis pressure and fluid absorption during ureteroscopy (URS) in a live porcine model.

Materials And Methods: Flexible URS (fURS) was performed in anaesthetised female Yorkshire pigs. Prior to performing fURS, a 0.

View Article and Find Full Text PDF

Objectives: A prior publication introduced the Strome-Blitzer balloon's ability to obtain circumferential esophageal cytologic sampling. This GLP study was requisite for FDA approval to determine if equivalent cell capture and cellularity was observed with the balloon compared to surface sampling brushes and to determine the balloon's usability for naive otolaryngologists.

Methods: Three naïve users tested the Hobbs brush and Strome-Blitzer balloon on 4 Yorkshire swine.

View Article and Find Full Text PDF

Purpose: To determine the number of runs with blades up (BU) using the JetStream Navitus to achieving optimal debulking in a porcine model of femoropopliteal artery in-stent restenosis (ISR).

Methods: In this porcine model, 8 limbs were implanted with overlapping nitinol self-expanding stents. ISR was treated initially with 2 blades-down (BD) runs followed by 4 BU runs (BU1 to BU4).

View Article and Find Full Text PDF