Eur J Clin Invest
April 2023
Background: Although cardiac resynchronization therapy (CRT) is beneficial in most heart failure patients, up to 40% do not respond to CRT. It has been suggested that multipoint left ventricle pacing (MPP) would increase the response rate.
Aim: To assess the CRT response rate at 6 months in patients implanted with a CRT device with the MPP feature activated early after the implant.
Aims: To determine the spectral dynamics of early spontaneous polymorphic ventricular tachycardia and ventricular fibrillation (PVT/VF) in humans.
Methods And Results: Fifty-eight self-terminated and 173 shock-terminated episodes of spontaneously initiated PVT/VF recorded by Medtronic implanted cardiac defibrillators (ICDs) in 87 patients with various cardiac pathologies were analyzed by short fast Fourier transform of shifting segments to determine the dynamics of dominant frequency (DF) and regularity index (RI). The progression in the intensity of DF and RI accumulations further quantified the time course of spectral characteristics of the episodes.
Background Large-scale studies describing modern populations using an implantable cardioverter-defibrillator (ICD) are lacking. We aimed to analyze the incidence of arrhythmia, device interventions, and mortality in a broad spectrum of real-world ICD patients with different heart disorders. Methods and Results The UMBRELLA study is a prospective, multicenter, nationwide study of contemporary patients using an ICD followed up by remote monitoring, with a blinded review of arrhythmic episodes.
View Article and Find Full Text PDFIntroduction: The clinical impact of slow ventricular tachycardia (VT), occurring in patients carrying implantable cardiac defibrillators (ICD), is still under debate.
Methods And Results: From the UMBRELLA registry (multicenter, observational, and prospective study on patients with ICD), 659 episodes of slow VT were observed in 97 patients. Untreated slow VT (n = 93) had longer duration (23.
Introduction And Objectives: The ADVANCE III trial showed that a delayed-detection strategy reduces implantable cardioverter-defibrillator (ICD) therapies. Here, we describe the adherence to and predictors of ADVANCE adoption and compare ICD therapy rates between patients with and without ADVANCE programming.
Methods: This observational retrospective study analyzed patients implanted with Medtronic ICDs included from 2005 to 2016 in a Spanish national multicenter registry (UMBRELLA database; ClinicalTrials.
Background: Premature ventricular contractions (PVC) are known to reduce the percentage of biventricular (BiV) pacing in patients with cardiac resynchronization (CRT), decreasing the clinical response. The aim of this study was to evaluate the prevalence of a high PVC burden, as well as therapeutic action (pharmacotherapy, catheter ablation or device programming), in a large CRT implantable-defibrillator (CRT-D) population.
Methods: Patients with a CRT-D device from the UMBRELLA multicenter prospective remote monitoring registry were included.
Background: Hypertrophic cardiomyopathy (HCM) carries an increased risk of sudden death due to ventricular arrhythmias (VAs). The implantable cardioverter-defibrillator (ICD) is a well-established therapy for treatment of VA. Monomorphic ventricular tachycardias (MVTs) are frequent in HCM patients and suitable for antitachycardia pacing (ATP) termination.
View Article and Find Full Text PDFIntroduction And Objectives: Atrioventricular block (AVB) in the presence of bradycardic drugs (BD) can be reversible, and pacemaker implantation is controversial. Our objective was to analyze the pacemaker implantation rate in the mid-term, after BD suspension, and to identify predictive factors.
Methods: We performed a cohort study that included patients attending the emergency department with high-grade AVB in the context of BD.
Aims: Atrial electrical remodelling (AER) is a transitional period associated with the progression and long-term maintenance of atrial fibrillation (AF). We aimed to study the progression of AER in individual patients with implantable devices and AF episodes.
Methods And Results: Observational multicentre study (51 centres) including 4618 patients with implantable cardioverter-defibrillator +/-resynchronization therapy (ICD/CRT-D) and 352 patients (2 centres) with pacemakers (median follow-up: 3.
Aims: Concerns about the prognostic value of NYHA functional class (FC) in heart failure (HF) patients carrying a prophylactic implantable cardioverter defibrillator (ICD) are still present. We aimed to compare whether mortality and arrhythmic risk were different, in a cohort of HF patients undergoing ICD-only implant, according to their FC.
Methods And Results: HF patients with left ventricle ejection fraction (LVEF) ≤35%, undergoing first prophylactic ICD-only implant were collected from a multicentre nationwide registry (2006-2015).
Purpose: Comparisons of the efficacy of dual- vs. single-chamber implantable cardioverter defibrillators (ICDs) in preventing inappropriate shocks have had contradictory results. We investigated whether dual-chamber devices have a lower risk of inappropriate shocks and the specific role of supraventricular tachycardia (SVT) discriminators.
View Article and Find Full Text PDFInt J Cardiol
January 2019
Background: Concerns about the efficacy of prophylactic ICD in non-ischemic cardiomyopathy (NICM) heart failure (HF) patients are still present. We aimed to assess whether survival and arrhythmic risk were different among ischemic cardiomyopathy (ICM) and NICM ICD-only patients, along with specific predictors for mortality.
Methods: HF patients undergoing ICD-only implant were extracted from the nationwide multicenter UMBRELLA registry.
Introduction: Arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) is an inherited cardiomyopathy characterized by ventricular arrhythmias and heart failure. The variable phenotype suggesting that determined environmental factors may have an influence. The aim of our study was to discover the impact of the dynamic physical activity on patients with high-risk definite ARVC/D.
View Article and Find Full Text PDFIntroduction And Objectives: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is an inherited cardiomyopathy characterized by progressive fibrofatty replacement of predominantly right ventricular myocardium. This cardiomyopathy is a frequent cause of sudden cardiac death in young people and athletes. The aim of our study was to determine the incidence of pathological or likely pathological desmosomal mutations in patients with high-risk definite ARVC.
View Article and Find Full Text PDFClin Res Cardiol
July 2018
Background: Hypertension is an important, modifiable risk factor for the development of atrial fibrillation (AF). Even after pulmonary vein isolation (PVI), 20-40% experience recurrent AF. Animal studies have shown that renal denervation (RDN) reduces AF inducibility.
View Article and Find Full Text PDFIntroduction And Objectives: Fast ventricular tachycardias in the ventricular fibrillation zone in patients with an implantable cardioverter-defibrillator are susceptible to antitachycardia pacing (ATP) termination. Some manufacturers allow programming 2 ATP bursts: before charging (BC) and during (DC) charging. The aim of this study was to describe the safety and effectiveness of ATP BC and DC for fast ventricular tachycardias in the ventricular fibrillation zone in patients with an implantable cardioverter-defibrillator in daily clinical practice.
View Article and Find Full Text PDFIntroduction And Objectives: To report the findings of the Spanish Implantable Cardioverter-defibrillator Registry for 2016 compiled by the Electrophysiology and Arrhythmias Section of the Spanish Society of Cardiology.
Methods: Prospective data were voluntarily recorded on a data collection form and send to the Spanish Society of Cardiology by each implantation team.
Results: Overall, 5673 device implantations were reported, representing 85% of the estimated total number of implantations.
Introduction And Objectives: We present the results of the Spanish Implantable Cardioverter-defibrillator Registry for 2015, as compiled by the Electrophysiology and Arrhythmia Section of the Spanish Society of Cardiology.
Methods: Data collection sheets were voluntarily completed by each implantation team and prospectively sent to the Spanish Society of Cardiology.
Results: The number of reported implantations was 5465 (85% of the estimated total number of implantations).
Aims: The benefit of implantable cardioverter-defibrillators (ICDs) in patients at risk of sudden death has been established in randomized clinical trials (RCTs) using the ICD models available at the time. However, observational large-scale data on the incidence of arrhythmias in up-to-date ICDs implanted according to the current guidelines are scarce. The aim was to assess the incidence of arrhythmias in a large, current ICD population based on a blinded peer review of the detected episodes.
View Article and Find Full Text PDFObjective: A safety threshold for baseline rhythm R-wave amplitudes during follow-up of implantable cardioverter defibrillators (ICD) has not been established. We aimed to analyse the amplitude distribution and undersensing rate during spontaneous episodes of ventricular fibrillation (VF), and define a safety amplitude threshold for baseline R-waves.
Methods: Data were obtained from an observational multicentre registry conducted at 48 centres in Spain.
Introduction And Objectives: The Sprint Fidelis defibrillator lead (Medtronic) was recalled in 2007 due to an increased risk of failure. The generator exchange (GE) procedure has been associated with the development of Fidelis lead dysfunction. The aim of this study was to compare the rate of dysfunction between Sprint Fidelis and other defibrillator leads during the first year after GE.
View Article and Find Full Text PDFPacing Clin Electrophysiol
July 2016
Background: Different types of ventricular arrhythmias (monomorphic ventricular tachycardia [VT], polymorphic VT, or ventricular fibrillation) can be detected by implantable cardiac defibrillators (ICDs) in fast VT zone. The efficacy of antitachycardia pacing (ATP) depends on the type of the treated arrhythmia. We hypothesized that an automatic algorithm based on morphological affinity of ICD far-field electrograms during tachycardia can predict ATP success and the need of shock.
View Article and Find Full Text PDFBackground: Atrial rate-responsive pacing (RRP) has proved to be safe in pacemaker recipients with chronotropic incompetence. Although RRP is available in all current implantable cardioverter defibrillators (ICDs), the outcomes of this pacing mode in ICD patients are unknown. The aim is to evaluate the relationship between atrial RRP and atrial arrhythmias in ICD recipients.
View Article and Find Full Text PDFAims: Cardiac resynchronization therapy (CRT) reduces the incidence of sudden cardiac death and the use of appropriate implantable cardioverter-defibrillator (ICD) therapies (AICDTs); however, this antiarrhythmic effect is only observed in certain groups of patients. To gain insight into the effects of CRT on ventricular arrhythmia (VA) burden, we compared the incidence of AICDT use in four groups of patients: patients with ischaemic cardiomyopathy vs. non-ischaemic dilated cardiomyopathy (NIDC) and patients implanted with an ICD vs.
View Article and Find Full Text PDFBackground: We sought to assess the efficacy of high-energy shocks to restore rhythm and predictors of success in patients with sustained ventricular arrhythmias and implantable cardioverter defibrillator (ICD).
Methods And Results: Data from 162 patients included in the UMBRELLA study that experienced one or more episodes of ventricular tachycardia (VT) for which ICD shocks of at least 30 Joules were delivered (appropriate high-energy shocks) were analyzed. In total, 456 ventricular arrhythmia episodes were registered.