Publications by authors named "Jatinderjit Kaur"

Introduction: The expansion of transcatheter aortic valve implantation (TAVI) to low-risk and younger patients has increased the relevance of the long-term durability of transcatheter heart valves (THV). The present study aims to assess the 10-year durability, hemodynamic performance, and clinical outcomes after TAVI using the CoreValve system.

Methods: An analysis from a prospective registry with predefined clinical and echocardiographic follow-up included 302 patients who underwent TAVI with the CoreValve system between 2007 and 2015.

View Article and Find Full Text PDF
Article Synopsis
  • * A study of 1,332 patients showed that those with an HFA-PEFF score of 5 or higher were generally older and had more health issues like atrial fibrillation and chronic kidney disease, leading to higher cardiovascular mortality and heart failure-related rehospitalization within two years.
  • * However, the HFA-PEFF score alone did not significantly predict cardiovascular mortality or rehospitalization, suggesting that additional clinical variables are needed for better risk assessment in this patient population. *
View Article and Find Full Text PDF

Objectives: The aim of this study was to characterize the feasibility of coronary angiography (CA) and percutaneous coronary intervention (PCI) in acute settings among patients who have undergone transcatheter aortic valve replacement (TAVR).

Background: Impaired coronary access after TAVR may be challenging and particularly in acute settings could have deleterious consequences.

Methods: In this international registry, data from patients with prior TAVR requiring urgent or emergent CA were retrospectively collected.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to evaluate clinical and echocardiographic outcome data of the CHOICE (Randomized Comparison of Transcatheter Heart Valves in High Risk Patients with Severe Aortic Stenosis: Medtronic CoreValve Versus Edwards SAPIEN XT) trial at 5 years.

Background: The CHOICE trial was designed to compare device performance of a balloon-expandable (BE) transcatheter heart valve (THV) versus a self-expanding (SE) THV.

Methods: The CHOICE trial is an investigator-initiated trial that randomized 241 high-risk patients with severe symptomatic aortic stenosis and an anatomy suitable for treatment with both BE and SE THVs to transfemoral transcatheter aortic valve replacement with either device.

View Article and Find Full Text PDF

Background Limited data exist on clinical valve thrombosis after transcatheter aortic valve-in-valve (ViV) implantation. Our objective was to determine the incidence, timing, clinical characteristics, and treatment outcomes of patients diagnosed with clinical ViV thrombosis. Methods and Results Centers participating in the Valve-in-Valve International Data Registry were surveyed for thrombosis cases, and clinical valve thrombosis was defined based on a combination of the presence of new valve dysfunction and an imaging evidence of leaflet thrombosis.

View Article and Find Full Text PDF

Objectives: The aim of this study was to compare self-expanding and balloon-expandable transcatheter heart valves (THVs) in large versus small aortic valve annuli.

Background: The degree of THV oversizing varies according to annular size, and this can modify the hemodynamic performance of self-expanding and balloon-expandable THVs.

Methods: Patients undergoing transcatheter aortic valve replacement in the randomized CHOICE (Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: Medtronic CoreValve vs Edwards SAPIEN XT) trial (CoreValve [CV], n = 120; SAPIEN XT [SXT], n = 121) and the nonrandomized CHOICE-Extend registry (Evolut R [ER], n = 100; SAPIEN 3 [S3], n = 334) were compared for THV performance by echocardiography (in all patients) and by cardiac magnetic resonance imaging (MRI) regurgitant fraction (RF) (in a subgroup of patients).

View Article and Find Full Text PDF

Objectives: To investigate the impact of the introduction of the next generation self-expanding (SE) and balloon-expandable (BE) transcatheter heart valves (THVs) on the incidence of prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR).

Background: PPM is a risk factor for accelerated degeneration of bioprosthetic aortic valves. Data on PPM after TAVR are derived mainly from studies of older generation THVs.

View Article and Find Full Text PDF

Aim: Atrial fibrosis, one of the most striking features in the pathology of atrial fibrillation (AF), is promoted by local and systemic inflammation. Electrophilic fatty acid nitroalkenes, endogenously generated by both metabolic and inflammatory reactions, are anti-inflammatory mediators that in synthetic form may be useful as drug candidates. Herein we investigate whether an exemplary nitro-fatty acid can limit atrial fibrosis and AF.

View Article and Find Full Text PDF