Publications by authors named "Jason Voorneveld"

Objective: Assessing myocardial perfusion in acute myocardial infarction is important for guiding clinicians in choosing appropriate treatment strategies. Echocardiography can be used due to its direct feedback and bedside nature, but it currently faces image quality issues and an inability to differentiate coronary macro- from micro-circulation. We previously developed an imaging scheme using high frame-rate contrast-enhanced ultrasound (HFR CEUS) with higher order singular value decomposition (HOSVD) that provides dynamic perfusion and vascular flow visualization.

View Article and Find Full Text PDF

Objective: Accurately measuring intracardiac flow patterns could provide insights into cardiac disease pathophysiology, potentially enhancing diagnostic and prognostic capabilities. This study aims to validate Echo-Particle Image Velocimetry (echoPIV) for in vivo left ventricular intracardiac flow imaging against 4D flow MRI.

Methods: We acquired high frame rate contrast-enhanced ultrasound images from three standard apical views of 26 patients who required cardiac MRI.

View Article and Find Full Text PDF

Purpose: To investigate the accuracy of high-framerate echo particle image velocimetry (ePIV) and computational fluid dynamics (CFD) for determining velocity vectors in femoral bifurcation models through comparison with optical particle image velocimetry (oPIV).

Approach: Separate femoral bifurcation models were built for oPIV and ePIV measurements of a non-stenosed (control) and a 75%-area stenosed common femoral artery. A flow loop was used to create triphasic pulsatile flow.

View Article and Find Full Text PDF

Objective: Block matching serves as the foundation for ultrasound velocimetry techniques such as blood speckle tracking and echo-particle image velocimetry. Any spatial velocity gradients (SVGs) inside a block-matching pair will result in tracking error, due to both the finite block size and the ultrasound point-spread-function. We assess, using an in silico sinusoidal flow phantom, the effect of SVG magnitude and beam-to-flow angle on block-matching bias and precision.

View Article and Find Full Text PDF

Purpose: Intraventricular blood flow dynamics are associated with cardiac function. Accurate, noninvasive, and easy assessments of hemodynamic quantities (such as velocity, vortex, and pressure) could be an important addition to the clinical diagnosis and treatment of heart diseases. However, the complex time-varying flow brings many challenges to the existing noninvasive image-based hemodynamic assessments.

View Article and Find Full Text PDF

Assessing the coronary circulation with contrast-enhanced echocardiography has high clinical relevance. However, it is not being routinely performed in clinical practice because the current clinical tools generally cannot provide adequate image quality. The contrast agent's visibility in the myocardium is generally poor, impaired by motion and nonlinear propagation artifacts.

View Article and Find Full Text PDF

Background: Local blood flow affects vascular disease and outcomes of endovascular treatment, but quantifying it is challenging, especially inside stents. We assessed the feasibility of blood flow quantification in native and stented femoral arteries, using high-frame-rate (HFR) contrast-enhanced ultrasound (CEUS) particle image velocimetry (PIV), also known as echoPIV.

Methods: Twenty-one patients with peripheral arterial disease, recently treated with a stent in the femoral artery, were included.

View Article and Find Full Text PDF

Ultrasound (US) contrast agents consist of microbubbles ranging from 1 to 10 μm in size. The acoustical response of individual microbubbles can be studied with high-frame-rate optics or an "acoustical camera" (AC). The AC measures the relative microbubble oscillation while the optical camera measures the absolute oscillation.

View Article and Find Full Text PDF

Suppressing tissue clutter is an essential step in blood flow estimation and visualization, even when using ultrasound contrast agents. Blind source separation (BSS)-based clutter filter for high-framerate ultrasound imaging has been reported to perform better in tissue clutter suppression than the conventional frequency-based wall filter and nonlinear contrast pulsing schemes. The most notable BSS technique, singular value decomposition (SVD) has shown compelling results in cases of slow tissue motion.

View Article and Find Full Text PDF

Local flow patterns influence stent patency, while blood flow quantification in stents is challenging. The aim of this study was to investigate the feasibility of 2-D blood flow quantification using high-frame-rate, contrast-enhanced ultrasound (HFR-CEUS) and particle image velocimetry (PIV), or echoPIV, in patients with aortoiliac stents. HFR-CEUS measurements were performed at 129 locations in 62 patients.

View Article and Find Full Text PDF

Background: Echo-Particle Image Velocimetry (echoPIV) tracks speckle patterns from ultrasound contrast agent(UCA), being less angle-sensitive than colour Doppler. High frame rate (HFR) echoPIV enables tracking of high velocity flow in the left ventricle (LV). We aimed to demonstrate the potential clinical use of HFR echoPIV and investigate the feasibility and accuracy in patients.

View Article and Find Full Text PDF

Background: The aim of this systematic review was to evaluate current inter-modality agreement of noninvasive clinical intraventricular flow (IVF) assessment with 3 emerging imaging modalities: echocardiographic particle image velocimetry (EPIV), vector flow mapping (VFM), and 4-dimensional flow cardiovascular magnetic resonance imaging (4D flow CMR).

Methods: We performed a systematic literature review in the databases EMBASE, Medline OVID and Cochrane Central for identification of studies evaluating left ventricular (LV) flow patterns using one of these flow visualization modalities. Of the 2224 initially retrieved records, 10 EPIV, 23 VFM, and 25 4D flow CMR studies were included in the final analysis.

View Article and Find Full Text PDF

Purpose: To assess errors associated with EPI-accelerated intracardiac 4D flow MRI (4DEPI) with EPI factor 5, compared with non-EPI gradient echo (4DGRE).

Methods: Three 3T MRI experiments were performed comparing 4DEPI to 4DGRE: steady flow through straight tubes, pulsatile flow in a left-ventricle phantom, and intracardiac flow in 10 healthy volunteers. For each experiment, 4DEPI was repeated with readout and blip phase-encoding gradient in different orientations, parallel or perpendicular to the flow direction.

View Article and Find Full Text PDF

Background The accurate quantification of blood flow in aortoiliac arteries is challenging but clinically relevant because local flow patterns can influence atherosclerotic disease. Purpose To investigate the feasibility and clinical application of two-dimensional blood flow quantification using high-frame-rate contrast-enhanced US (HFR-CEUS) and particle image velocimetry (PIV), or US velocimetry, in participants with aortoiliac stenosis. Materials and Methods In this prospective study, participants with a recently diagnosed aortoiliac stenosis underwent HFR-CEUS measurements of the pre- and poststenotic vessel segments (August 2018 to July 2019).

View Article and Find Full Text PDF

High-frame-rate (HFR) echo-particle image velocimetry (echoPIV) is a promising tool for measuring intracardiac blood flow dynamics. In this study, we investigate the optimal ultrasound contrast agent (UCA: SonoVue) infusion rate and acoustic output to use for HFR echoPIV (PRF = 4900 Hz) in the left ventricle (LV) of patients. Three infusion rates (0.

View Article and Find Full Text PDF

: Detailed blood flow studies may contribute to improvements in carotid artery stenting. High-frame-rate contrast-enhanced ultrasound followed by particle image velocimetry (PIV), also called echoPIV, is a technique to study blood flow patterns in detail. The performance of echoPIV in presence of a stent has not yet been studied extensively.

View Article and Find Full Text PDF

Natural and active shear wave elastography (SWE) are potential ultrasound-based techniques to non-invasively assess myocardial stiffness, which could improve current diagnosis of heart failure. This study aims to bridge the knowledge gap between both techniques and discuss their respective impacts on cardiac stiffness evaluation. We recorded the mechanical waves occurring after aortic and mitral valve closure (AVC, MVC) and those induced by acoustic radiation force throughout the cardiac cycle in four pigs after sternotomy.

View Article and Find Full Text PDF

Cardiac function and vascular function are closely related to the flow of blood within. The flow velocities in these larger cavities easily reach 1 m/s, and generally complex spatiotemporal flow patterns are involved, especially in a non-physiologic state. Visualization of such flow patterns using ultrasound can be greatly enhanced by administration of contrast agents.

View Article and Find Full Text PDF

Left ventricular (LV) blood flow is an inherently complex time-varying 3-D phenomenon, where 2-D quantification often ignores the effect of out-of-plane motion. In this study, we describe high frame rate 4-D echocardiographic particle image velocimetry (echo-PIV) using a prototype matrix transesophageal transducer and a dynamic LV phantom for testing the accuracy of echo-PIV in the presence of complex flow patterns. Optical time-resolved tomographic PIV (tomo-PIV) was used as a reference standard for comparison.

View Article and Find Full Text PDF

Left ventricular flow is intrinsically complex, three-dimensional and unsteady. Its features are susceptible to cardiovascular pathology and treatment, in particular to surgical interventions involving the valves (mitral valve replacement). To improve our understanding of intraventricular fluid mechanics and the impact of various types of prosthetic valves thereon, we have developed a custom-designed versatile left ventricular phantom with anatomically realistic moving left ventricular membrane.

View Article and Find Full Text PDF

Purpose To study the feasibility of high-frame-rate (HFR) contrast material-enhanced (CE) ultrasound particle image velocimetry (PIV), or echo PIV, in the abdominal aorta. Materials and Methods Fifteen healthy participants (six men; median age, 23 years [age range, 18-34 years]; median body mass index, 20.3 kg/m [range, 17.

View Article and Find Full Text PDF

Treatment of abdominal aortic (AA) aneurysms and stenotic lesions may be improved by analyzing their associated blood-flow patterns. Angle-independent blood-flow patterns in the AA can be obtained by combining echo-particle image velocimetry (ePIV) with high-frame-rate (HFR) contrast-enhanced ultrasonography. However, ePIV performance is affected by ultrasound contrast agent (UCA) concentration, microbubble stability, and tissue clutter.

View Article and Find Full Text PDF
Article Synopsis
  • Echocardiographic techniques for analyzing blood flow in the left ventricle are challenging, but this study explores a new method using high frame rate echo-particle image velocimetry (ePIV).
  • The study compares ePIV with the established optical particle image velocimetry (oPIV) in a left ventricular phantom and finds that ePIV performs well, with a low error rate for high-velocity inflows.
  • Although ePIV has some limitations in resolving smaller flow details due to its coarser resolution, both techniques show strong agreement in capturing the main flow patterns and energy structures within the left ventricle.
View Article and Find Full Text PDF