Relaxation rates R in the rotating frame measured by spin-lock methods at very low locking amplitudes (≤ 100 Hz) are sensitive to the effects of water diffusion in intrinsic gradients and may provide information on tissue microvasculature, but accurate estimates are challenging in the presence of B and B inhomogeneities. Although composite pulse preparations have been developed to compensate for nonuniform fields, the transverse magnetization comprises different components and the spin-lock signals measured do not decay exponentially as a function of locking interval at low locking amplitudes. For example, during a typical preparation sequence, some of the magnetization in the transverse plane is nutated to the Z-axis and later tipped back, and so does not experience R relaxation.
View Article and Find Full Text PDFIntroduction: Simultaneous mapping of triglyceride (TAG) saturation and tissue water relaxation may improve the characterization of the structure and function of anatomies with significant adipose tissue. While several groups have demonstrated in vivo TAG saturation imaging using MRI, joint mapping of relaxation and TAG saturation is understudied. Such mappings may avoid bias from physiological motion, if they can be done within a single breath-hold, and also account for static and applied magnetic field heterogeneity.
View Article and Find Full Text PDFPurpose: Slice-selective, gradient-crushed, transient-state sequences such as those used in MR fingerprinting (MRF) relaxometry are sensitive to slice profile effects. Whereas balanced steady-state free precession MRF profile effects have been studied, less attention has been given to gradient-crushed MRF forms. Extensions of the extended phase graph (EPG) formalism, called slice-selective EPG (ssEPG), are proposed that model slice profile effects.
View Article and Find Full Text PDFPurpose: Magnetic resonance fingerprinting (MRF) is a state-of-the-art quantitative MRI technique with a computationally demanding reconstruction process, the accuracy of which depends on the accuracy of the signal model employed. Having a fast, validated, open-source MRF reconstruction would improve the dependability and accuracy of clinical applications of MRF.
Methods: We parallelized both dictionary generation and signal matching on the GPU by splitting the simulation and matching of dictionary atoms across threads.
Purpose: MR fingerprinting (MRF) sequences permit efficient T and T estimation in cranial and extracranial regions, but these areas may include substantial fat signals that bias T and T estimates. MRI fat signal fraction estimation is also a topic of active research in itself, but may be complicated by B heterogeneity and blurring during spiral k-space acquisitions, which are commonly used for MRF. An MRF method is proposed that separates fat and water signals, estimates water T and T, and accounts for B effects with spiral blurring correction, in a single sequence.
View Article and Find Full Text PDFMagnetic resonance fingerprinting (MRF) pulse sequences often employ spiral trajectories for data readout. Spiral k-space acquisitions are vulnerable to blurring in the spatial domain in the presence of static field off-resonance. This work describes a blurring correction algorithm for use in spiral MRF and demonstrates its effectiveness in phantom and in vivo experiments.
View Article and Find Full Text PDFPurpose: Diffusion-weighted imaging (DWI) and F-fluorodeoxyglucose-positron emission tomography ( F-FDG-PET) independently correlate with malignancy in breast cancer, but the relationship between their structural and metabolic metrics is not completely understood. This study spatially correlates diffusion, perfusion, and glucose avidity in breast cancer with simultaneous PET/MR imaging and compares correlations with clinical prognostics.
Methods: In this Health Insurance Portability and Accountability Act-compliant prospective study, with written informed consent and approval of the institutional review board and using simultaneously acquired FDG-PET and DWI, tissue diffusion (D ), and perfusion fraction (f ) from intravoxel incoherent motion (IVIM) analysis were registered to FDG-PET within 14 locally advanced breast cancers.
Background: Metallic airway stents are often used in the management of central airway malignancies. The presence of a metallic foreign body may affect radiation dose in tissue. We studied the effect of a metallic airway stent on radiation dose delivery in a phantom and an in vivo porcine model.
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
April 2012
Purpose: The use of T2 MR for postimplant dosimetry (PID) after prostate brachytherapy allows more anatomically accurate and precise contouring but does not readily permit seed identification. We developed a reproducible technique for performing MR-CT fusion and compared the resulting dosimetry to standard CT-based PID.
Methods And Materials: CT and T1-weighted MR images for 45 patients were fused and aligned based on seed distribution.