Publications by authors named "Janotka M"

Article Synopsis
  • - The study evaluates the mid-term to long-term retrieval and reimplantation of a leadless pacemaker (Micra TPS) in a single medical center.
  • - Out of nine patients who underwent retrieval attempts after an average of 3.1 years, 88.9% were successfully retrieved, with no major complications reported.
  • - The successful retrieval procedure allows for replacement with either a new Micra device or a traditional pacemaker, offering a better management option at the end of the device's life compared to simply discarding it.
View Article and Find Full Text PDF
Article Synopsis
  • The study evaluated the 1-year outcomes of the ECMO-CS trial, which compared immediate ECMO initiation to an early conservative approach in patients with severe cardiogenic shock.
  • Results showed no significant difference in all-cause mortality or other critical outcomes between the two strategies after one year.
  • However, there was a suggestion that immediate ECMO could be more beneficial for patients with significantly low mean arterial pressure at baseline, indicating a possible targeted use for this treatment strategy.
View Article and Find Full Text PDF

Transcatheter aortic valve replacement (TAVR) is a minimally invasive therapeutic procedure with a consistent, linear increase in the number of implantations worldwide. Recently, TAVR has been rapidly expanding into lower-risk populations. Sporadic cases of late prosthesis-related Stanford type A dissection have been documented in self-expanding, as well as balloon-expandable TAVR valves, manifested primarily as acute aortic syndrome.

View Article and Find Full Text PDF

Background: Visually guided laser balloon ablation is known as an effective pulmonary vein (PV) isolation device. The third-generation laser balloon ablation system (X3) equipped with compliant balloon and an automated motor-driven laser output mechanism, namely RAPID mode, has been clinically proven for PV isolation.

Methods: PV isolation with X3 was performed in all the patients with paroxysmal and early-stage persistent atrial fibrillation (AF).

View Article and Find Full Text PDF
Article Synopsis
  • The study examined the impact of acute cardiac failure (CF) on heart rate variability (HRV) using 24 female pigs subjected to global myocardial hypoxia.
  • The results indicated a significant drop in cardiac output and left ventricular ejection fraction, along with an increased heart rate after severe CF was induced.
  • Key findings showed a marked reduction in HRV measurements across various analytical methods, highlighting the adverse effects of acute CF on autonomic nervous system function.
View Article and Find Full Text PDF

Veno-venous extracorporeal membrane oxygenation (VV-ECMO) is a life-saving treatment for respiratory failure that may serve as a bridge to patient recovery or lung transplantation. In COVID-19, recovery is somewhat unpredictable and occasionally occurs after >100 days on VV-ECMO support. Thus, determining therapy cessation may be difficult.

View Article and Find Full Text PDF
Article Synopsis
  • The ECMO-CS trial investigated the effectiveness of immediate veno-arterial extracorporeal membrane oxygenation (VA-ECMO) compared to a conservative therapy approach for patients with severe cardiogenic shock.
  • The study included 117 patients who were randomly assigned to receive either immediate VA-ECMO or the conservative approach, which allowed for VA-ECMO use if conditions worsened.
  • Results showed similar outcomes in terms of death, cardiac arrest, and adverse events between the two groups, suggesting no significant benefit from immediate VA-ECMO.
View Article and Find Full Text PDF

Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is widely used in the treatment of patients experiencing cardiogenic shock (CS). However, increased VA-ECMO blood flow (EBF) may significantly impair left ventricular (LV) performance. The objective of the present study was to assess the effect of VA-ECMO on LV function in acute CS with concomitant severe aortic stenosis (AS) or mitral regurgitation (MR) in a porcine model.

View Article and Find Full Text PDF

Background: Pulsed field ablation (PFA) has a unique safety profile when used to treat atrial fibrillation, largely related to its preferentiality for myocardial tissue ablation, in particular, esophageal sparing. A pentaspline catheter was the first such PFA system studied clinically for atrial fibrillation ablation; in these initial regulatory trials, the catheter was used for pulmonary vein isolation and left atrial posterior wall ablation. Since its regulatory approval in Europe, in clinical practice, physicians have ablated beyond pulmonary vein isolation and left atrial posterior wall ablation to expanded lesion sets in closer proximity to coronary arteries.

View Article and Find Full Text PDF

This is the first report of the management of a patient with cardiac resynchronization therapy using leadless biventricular pacing. Successful retrieval of a 4-year-old Micra transcatheter pacing system (TPS) and reimplantation of a new Micra TPS prevented device-to-device interactions from multiple pacing devices in the right ventricle. ().

View Article and Find Full Text PDF

Introduction: When cardiac magnetic resonance (MR) is performed after previous leadless transcatheter pacemaker implantation, an image distortion has to be expected in the heart region and evaluation of myocardial tissue can be affected. In this clinical prospective study, we aim to assess the extent and impact of this artifact on individual ventricular segments and compare it to conventional pacing devices.

Methods: Total of 20 patients with leadless pacemaker placed in the right ventricle underwent cardiac MR imaging in a 1.

View Article and Find Full Text PDF

The assessment and monitoring of the tissue perfusion is extremely important in critical conditions involving circulatory shock. There is a wide range of established methods for the assessment of cardiac output as a surrogate of oxygen delivery to the peripheral tissues. However, the evaluation of whether particular oxygen delivery is sufficient to ensure cellular metabolic demands is more challenging.

View Article and Find Full Text PDF

Objectives: The authors report their single-center experience with the retrieval and replacement of long-term implanted leadless cardiac pacemakers (LPs) and the factors contributing to success.

Background: LPs are a clinically effective and safe alternative to standard transvenous pacemakers for single-chamber ventricular pacing. However, the feasibility of retrieving and replacing long-term implanted LPs is not well known.

View Article and Find Full Text PDF

Background: Continuous, reliable evaluation of left ventricular (LV) contractile function in patients with advanced heart failure requiring intensive care remains challenging. Continual monitoring of dP/dt from the arterial line has recently become available in hemodynamic monitoring. However, the relationship between arterial dP/dt and LV dP/dt remains unclear.

View Article and Find Full Text PDF

Introduction: Veno-arterial extracorporeal life support (ECLS) is increasingly being used to treat rapidly progressing or severe cardiogenic shock. However, it has been repeatedly shown that increased afterload associated with ECLS significantly diminishes left ventricular (LV) performance. The objective of the present study was to compare LV function and coronary flow during standard continuous-flow ECLS support and electrocardiogram (ECG)-synchronized pulsatile ECLS flow in a porcine model of cardiogenic shock.

View Article and Find Full Text PDF

Background: Despite marked advances in intensive cardiology care, current options for outcome prediction in cardiac arrest survivors remain significantly limited. The aim of our study was, therefore, to compare the day-specific association of neuron-specific enolase (NSE) with outcomes in out-of-hospital cardiac arrest (OHCA) survivors treated with hypothermia.

Methods: Eligible patients were OHCA survivors treated with targeted temperature management at 33 °C for 24 h using an endovascular device.

View Article and Find Full Text PDF

Aims: Extracorporeal membrane oxygenation (ECMO) in veno-arterial configuration represents an increasingly used method for circulatory support. ECMO in cardiogenic shock offers rapid improvement of circulatory status and significant increase in tissue perfusion. Current evidence on the use of ECMO in cardiogenic shock remains insufficient.

View Article and Find Full Text PDF

Despite the urgent need for experimental research in the field of acute heart failure and, particularly cardiogenic shock, currently there are only limited options in large animal models enabling research using devices applied to human subjects. The majority of available models are either associated with an unacceptably high rate of acute mortality or are incapable of developing sufficient severity of acute heart failure. The objective of our research was to develop a novel large animal model of acute severe cardiogenic shock.

View Article and Find Full Text PDF

Background: Transcatheter left atrial appendage closure is an alternative therapy for stroke prevention in atrial fibrillation patients. These procedures are currently guided with transesophageal echocardiography and fluoroscopy in most centers. As intracardiac echocardiography (ICE) is commonly used in other catheter-based procedures, we sought to determine the safety and effectiveness of intracardiac echocardiography-guided left atrial appendage closure with the Watchman device.

View Article and Find Full Text PDF

Introduction: Catheter ablation is an effective treatment of scar-related ventricular tachycardia (VT), but the overall complexity of the procedure has precluded its widespread use. Remote magnetic navigation (RMN) has been shown to facilitate cardiac mapping and ablation of VT in a retrospective series. STOP-VT is the first multicenter, prospective, single-arm and single-procedure study evaluating RMN-based mapping and ablation of post-infarction VT.

View Article and Find Full Text PDF

Purpose: We evaluated the correlation between pulmonary venous (PV) anatomy and acute and long-term success of PV isolation (PVI) with two balloon-based ablation catheter techniques.

Methods: One hundred consecutive patients were analyzed in two equal groups treated with either the second-generation cryoballoon (CRYO) catheter or the visually guided laser ablation (VGLA) catheter. All patients underwent multi-detector computed tomography (CT) imaging.

View Article and Find Full Text PDF

The protective effects of ischemic postconditioning (IPC) and nitric oxide (NO) administration have been demonstrated in several ischemic scenarios. However, current evidence regarding the effect of IPC and NO in extracorporeal cardiopulmonary resuscitation remains lacking. Fifteen female swine (body weight 45 kg) underwent veno-arterial extracorporeal membrane oxygenation (ECMO) implantation; cardiac arrest-ventricular fibrillation was induced by rapid ventricular pacing.

View Article and Find Full Text PDF

Background: The aim of this study was to assess the relationship between extracorporeal blood flow (EBF) and left ventricular (LV) performance during venoarterial extracorporeal membrane oxygenation (VA ECMO) therapy.

Methods: Five swine (body weight 45 kg) underwent VA ECMO implantation under general anesthesia and artificial ventilation. Subsequently, acute cardiogenic shock with signs of tissue hypoxia was induced.

View Article and Find Full Text PDF

Aims: Our aim was to evaluate the potential for safely imaging patients with a new type of implantable cardioverter-defibrillator called the subcutaneous implantable cardioverter-defibrillator (S-ICD) in a 1.5 T magnetic resonance imaging (MRI) scanner. With the increasing number of patients with cardiac implantable devices who are indicated for MRI, there is a growing need for establishing MRI compatibility of cardiac implantable devices.

View Article and Find Full Text PDF

Aims: Durable isolation of the pulmonary veins (PVs) remains the cornerstone of treatment for paroxysmal atrial fibrillation (PAF) and is also used in the treatment of some patients with persistent atrial fibrillation. Visually guided laser ablation (VGLA) has been proven to be safe and effective as a treatment for atrial fibrillation (AF). It has shown high levels of durable PV isolation (PVI), even in the hands of less experienced users.

View Article and Find Full Text PDF