Publications by authors named "Janelle E Bender"

We describe the potential of 5-aminolevulinic acid (ALA)-induced protoporphyrin IX (PpIX) fluorescence as a source of contrast for margin detection in commonly diagnosed breast cancer subtypes. Fluorescence intensity of PpIX in untreated and ALA-treated normal mammary epithelial and breast cancer cell lines of varying estrogen receptor expression were quantitatively imaged with confocal microscopy. Percentage change in fluorescence intensity integrated over 610-700 nm (attributed to PpIX) of posttreated compared to pretreated cells showed statistically significant differences between four breast cancer and two normal mammary epithelial cell lines.

View Article and Find Full Text PDF

We conducted a pilot study on 10 patients undergoing general surgery to test the feasibility of diffuse reflectance spectroscopy in the visible wavelength range as a noninvasive monitoring tool for blood loss during surgery. Ratios of raw diffuse reflectance at wavelength pairs were tested as a first-pass for estimating hemoglobin concentration. Ratios can be calculated easily and rapidly with limited post-processing, and so this can be considered a near real-time monitoring device.

View Article and Find Full Text PDF

We have a toolbox to quantify tissue optical properties that is composed of specialized fiberoptic probes for UV-visible diffuse reflectance spectroscopy and a fast, scalable inverse Monte Carlo (MC) model. In this paper, we assess the robustness of the toolbox for quantifying physiologically relevant parameters from turbid tissue-like media. In particular, we consider the effects of using different instruments, fiberoptic probes, and instrument-specific settings for a wide range of optical properties.

View Article and Find Full Text PDF

A diffuse reflectance spectroscopy system was modified as a step towards miniaturization and spectral imaging of tissue absorption and scattering. The modified system uses a tunable source and an optical fiber for illumination and a photodiode in contact with tissue for detection. Compared to the previous system, it is smaller, less costly, and has comparable performance in extracting optical properties in tissue phantoms.

View Article and Find Full Text PDF

A hybrid optical device that uses a multimode fiber coupled to a tunable light source for illumination and a 2.4-mm photodiode for detection in contact with the tissue surface is developed as a first step toward our goal of developing a cost-effective, miniature spectral imaging device to map tissue optical properties in vivo. This device coupled with an inverse Monte Carlo model of reflectance is demonstrated to accurately quantify tissue absorption and scattering in tissue-like turbid synthetic phantoms with a wide range of optical properties.

View Article and Find Full Text PDF

Calibration of the diffuse reflectance spectrum for instrument response and time-dependent fluctuation as well as interdevice variations is complicated, time consuming, and potentially inaccurate. We describe a novel fiber optic probe with a real-time self-calibration capability that can be used for tissue optical spectroscopy. The probe was tested in a number of liquid phantoms over a relevant range of tissue optical properties.

View Article and Find Full Text PDF

This paper describes the implementation of neutron-stimulated emission computed tomography (NSECT) for non-invasive imaging and reconstruction of a multi-element phantom. The experimental apparatus and process for acquisition of multi-spectral projection data are described along with the reconstruction algorithm and images of the two elements in the phantom. Independent tomographic reconstruction of each element of the multi-element phantom was performed successfully.

View Article and Find Full Text PDF

Neutron stimulated emission computed tomography (NSECT) is being developed to noninvasively determine concentrations of trace elements in biological tissue. Studies have shown prominent differences in the trace element concentration of normal and malignant breast tissue. NSECT has the potential to detect these differences and diagnose malignancy with high accuracy with dose comparable to that of a single mammogram.

View Article and Find Full Text PDF

Neutron stimulated emission computed tomography (NSECT) is presented as a new technique for in vivo tomographic spectroscopic imaging. A full implementation of NSECT is intended to provide an elemental spectrum of the body or part of the body being interrogated at each voxel of a three-dimensional computed tomographic image. An external neutron beam illuminates the sample and some of these neutrons scatter inelastically, producing characteristic gamma emission from the scattering nuclei.

View Article and Find Full Text PDF

Computer simulation is used to facilitate the design of fiber-probe geometries that enable enhanced detection of optical signals arising from specific tissue depths. Obtaining understanding of the relationship between fiber-probe design and tissue interrogation is critical when developing strategies for optical detection of epithelial precancers that originate at known depths from the tissue surface. The accuracy of spectroscopic diagnostics may be enhanced by discretely probing the optical properties of epithelium and underlying stroma, within which the morphological and biochemical features vary as a function of depth.

View Article and Find Full Text PDF