Publications by authors named "Jan E. Vandevenne"

Gossypiboma is a rare post-surgical complication comprising a retained surgical gauze surrounded by a foreign body reaction. Although usually presenting on magnetic resonance imaging (MRI) with low T1 signal, high central and low peripheral signal on T2, and bandlike peripheral enhancement, MR appearance is often non-specific. The barium sulphate filament within a surgical gauze presents on MR as a curvilinear thread which is dark on both T1 and T2 sequences.

View Article and Find Full Text PDF

Purpose: Assessment of bony fusion following anterior cervical interbody fusion (ACIF) is usually done by plain film or CT. We present the first clinical application of Cone-Beam CT (CBCT) to evaluate bony fusion after ACIF.

Methods: A 56-year-old man with disc herniation at C6-C7 underwent ACIF surgery using a compressed nanocrystalline hydroxyapatite interbody device (nanOss-C, Pioneer Surgical Marquette, MI, USA) and a nanocrystalline hydroxyapatite bone graft filler (nanOss Bioactive, Pioneer Surgical Marquette, MI, USA).

View Article and Find Full Text PDF

Purpose: The purpose of this paper was to evaluate if short volumetric interpolated breath-hold examination (VIBE) sequences can be used as a substitute for T1-weighted with fat saturation (T1-FS) sequences when performing magnetic resonance (MR) arthrography to diagnose rotator cuff tears.

Materials And Methods: Eighty-two patients underwent direct MR arthrography of the shoulder joint using VIBE (acquisition time of 13 s) and T1-FS (acquisition time of 5 min) sequences in the axial and paracoronal plane on a 1.0-T MR unit.

View Article and Find Full Text PDF

This study demonstrates the feasibility and advantages of near real-time, multiplanar, dynamic magnetic resonance image-assisted treatment of patients with developmental dysplasia of the hip. Pathoanatomy and dynamic blocks to reduction are visualized with anatomic clarity not otherwise possible. Continuous imaging allows accurate assessment and maintenance of optimum positioning throughout the casting procedure.

View Article and Find Full Text PDF

Purpose: To evaluate the safety of and time required for a broad range of musculoskeletal interventional procedures performed by using magnetic resonance (MR) imaging guidance with a vertically open 0.5-T unit.

Materials And Methods: Sixty-three MR imaging-guided procedures were performed.

View Article and Find Full Text PDF

The presence of a soft tissue mass in children is of concern to parents and physicians. Fortunately, these masses are rare and usually benign or pseudotumoral. When dealing with malignant soft tissue tumors, therapeutic options and long-term survival are strongly related to the disease stage at the time of diagnosis.

View Article and Find Full Text PDF