A previous study used a PortaCount Plus to measure the ratio of particle concentrations outside (C out) to inside (C in) of filtering facepiece respirators (FFRs) worn by test subjects and calculated the total inward leakage (TIL) (C in/C out) to evaluate the reproducibility of the TIL test method between two different National Institute for Occupational Safety and Health laboratories (Laboratories 1 and 2) at the Pittsburgh Campus. The purpose of this study is to utilize the originally obtained PortaCount C out/C in ratio as a measure of protection factor (PF) and evaluate the influence of particle distribution and filter efficiency. PFs were obtained for five N95 model FFRs worn by 35 subjects for three donnings (5 models × 35 subjects × 3 donnings) for a total of 525 tests in each laboratory.
View Article and Find Full Text PDF