Publications by authors named "James S Cooper"

Exposing a thiol-functionalised gold nanoparticle film chemiresistor to methanol in aqueous solution results in only a small electric current response as the thiol ligand/water partition coefficient of methanol is small, leading to only minor swelling of the chemiresistor film. Nevertheless, the current response to methanol can be enhanced if the chemiresistor becomes pre-exposed to a molecule with a large ligand/water partition coefficient P (e.g.

View Article and Find Full Text PDF

Chemiresistor sensor arrays are a promising technology to replace current laboratory-based analysis instrumentation, with the advantage of facile integration into portable, low-cost devices for in-field use. To increase the performance of chemiresistor sensor arrays a high-throughput fabrication and screening methodology was developed to assess different organothiol-functionalized gold nanoparticle chemiresistors. This high-throughput fabrication and testing methodology was implemented to screen a library consisting of 132 different organothiol compounds as capping agents for functionalized gold nanoparticle chemiresistor sensors.

View Article and Find Full Text PDF

Functionalised gold nanoparticle (Au(NP)) chemiresistors are investigated for direct sensing of small organic molecules in biological fluids. The principle reason that Au(NP) chemiresistors, and many other sensing devices, have limited operation in biological fluids is due to protein and lipid fouling deactivating the sensing mechanism. In order to extend the capability of such chemiresistor sensors to operate directly in biofluids, it is essential to minimise undesirable matrix effects due to protein and lipidic components.

View Article and Find Full Text PDF

We investigate the response dynamics of 1-hexanethiol-functionalized gold nanoparticle chemiresistors exposed to the analyte octane in aqueous solution. The dynamic response is studied as a function of the analyte-water flow velocity, the thickness of the gold nanoparticle film and the analyte concentration. A theoretical model for analyte limited mass-transport is used to model the analyte diffusion into the film, the partitioning of the analyte into the 1-hexanethiol capping layers and the subsequent swelling of the film.

View Article and Find Full Text PDF

Gold nanoparticle films (Au(NPF)) functionalized with a range of hydrophobic and hydrophilic thiols were assembled in chemiresistor sensor arrays that were used to differentiate between complex mixtures of analytes in the aqueous phase. A chemiresistor array sampled a simple system of linear alcohols (methanol, ethanol, propan-1-ol, and butan-1-ol) dissolved in water over a range of concentrations. Discriminant analysis confirmed that the response patterns of the array could be used to successfully distinguish between the different alcohol solutions at concentrations above 20 mM for all of the alcohols except methanol, which was distinguished at concentrations above 200 mM.

View Article and Find Full Text PDF