The goal of this work is to validate the use of the Exradin W1 plastic scintillation detector (PSD) to measure profiles and output factors from Gamma Knife Perfexion collimators in a Lucy phantom. The Exradin W1 PSD has a small-volume, near-water-equivalent, energy-independent sensitive element. Output measurements were performed for all 3 collimators (4 mm, 8 mm, and 16 mm) of the Gamma Knife Perfexion system, and these measurements were compared to measurements made with an A16 ion chamber and an EBT3 film and to the nominal values.
View Article and Find Full Text PDFPurpose: We seek to establish the feasibility of using spine stereotactic radiosurgery (SSRS), allowing for spinal cord dose constraint relaxation, as the primary management of metastatic epidural spinal cord compression (MESCC) in inoperable patients.
Methods And Materials: Inoperable patients with thoracic MESCC and no history of radiation were enrolled on this prospective phase 1 single-institution protocol. SSRS was delivered to a histology-dependent prescription dose of 18 or 24 Gy.
Objective: The objective of this study was to assess outcomes after Gamma Knife radiosurgery (GKRS) re-irradiation for palliation of patients with trigeminal pain secondary to recurrent malignant skull base tumors.
Methods: From 2009 to 2016, 26 patients who had previously undergone radiation treatment to the head and neck received GKRS for palliation of trigeminal neuropathic pain secondary to recurrence of malignant skull base tumors. Twenty-two patients received single-fraction GKRS to a median dose of 17 Gy (range 15-20 Gy) prescribed to the 50% isodose line (range 43%-55%).
Purpose: We sought to validate the Prognostic Index for Spinal Metastases (PRISM), a scoring system that stratifies patients into subgroups by overall survival.Methods and materials: The PRISM was previously created from multivariate Cox regression with patients enrolled in prospective single institution trials of stereotactic spine radiosurgery (SSRS) for spinal metastasis. We assess model calibration and discrimination within a validation cohort of patients treated off-trial with SSRS for metastatic disease at the same institution.
View Article and Find Full Text PDFThe purpose of this study is to identify regions of spinal column in which more than three contiguous vertebrae can be reliably and quickly aligned within 1 mm using a 6-degree (6D) couch and full body immobilization device. We analyzed 45 cases treated over a 3-month period. Each case was aligned using ExacTrac x-ray positioning system with integrated 6D couch to be within 1° and 1 mm in all six dimensions.
View Article and Find Full Text PDFBackground: Patients with glioblastoma multiforme (GBM) require radiotherapy as part of definitive management. Our institution has adopted the use of volumetric arc therapy (VMAT) due to superior sparing of the adjacent organs at risk (OARs) compared to intensity modulated radiation therapy (IMRT). Here we report our clinical experience by analyzing target coverage and sparing of OARs for 90 clinical treatment plans.
View Article and Find Full Text PDFThe purpose of this study was to investigate the setup and positioning uncertainty of a custom cushion/mask/bite-block (CMB) immobilization system and determine PTV margin for image-guided head and neck stereotactic ablative radiotherapy (HN-SABR). We analyzed 105 treatment sessions among 21 patients treated with HN-SABR for recurrent head and neck cancers using a custom CMB immobilization system. Initial patient setup was performed using the ExacTrac infrared (IR) tracking system and initial setup errors were based on comparison of ExacTrac IR tracking system to corrected online ExacTrac X-rays images registered to treatment plans.
View Article and Find Full Text PDFOBJECTIVE The objective of this study was to compare fractionation schemes and outcomes of patients with renal cell carcinoma (RCC) treated in institutional prospective spinal stereotactic radiosurgery (SSRS) trials who did not previously undergo radiation treatment at the site of the SSRS. METHODS Patients enrolled in 2 separate institutional prospective protocols and treated with SSRS between 2002 and 2011 were included. A secondary analysis was performed on patients with previously nonirradiated RCC spinal metastases treated with either single-fraction (SF) or multifraction (MF) SSRS.
View Article and Find Full Text PDFPurpose: To assess the dosimetric effects of respiratory motion on the target and spinal cord in spinal stereotactic body radiation therapy (SBRT).
Methods And Materials: Thirty patients with 33 lesions were enrolled on a prospective clinical protocol and simulated with both free-breathing and four-dimensional (4-D) computed tomography (CT). We studied the target motion using 4-D data (10 phases) by registering a secondary image dataset (phase 1 to 9) to a primary image dataset (phase 0) and analyzing the displacement in both translational and rotational directions.
In order to accurately assess positioning errors in spinal SBRT, many institutions employ bony-fusion based imaging techniques, such as the ExacTrac™ (Brain Lab) system, in conjunction with 3D verification (performed via CT-on-rails in our practice). We hypothesized that the use of implanted gold fiducial markers could improve the accuracy of patient positioning over bony fusion alone. We addressed this question prospectively, enrolling patients on an IRB-approved protocol.
View Article and Find Full Text PDFBackground: Removal of a pin during Gamma Knife stereotactic radiosurgery (GK-SRS) may be necessary to prevent collision and allow treatment.
Objective: To investigate outcomes after GK-SRS for treatment of brain metastases using a head frame immobilized to the skull with only 3 pins.
Methods: Between 2009 and 2014, we retrospectively reviewed the records of 1971 patients and identified 20 patients with multiple brain metastases treated with GK-SRS in which 1 anterior pin was removed immediately before treatment of a single posterior lesion.
Purpose: There exists uncertainty in the prognosis of patients following spinal metastasis treatment. We sought to create a scoring system that stratifies patients based on overall survival.
Methods And Materials: Patients enrolled in 2 prospective trials investigating stereotactic spine radiation surgery (SSRS) for spinal metastasis with ≥ 3-year follow-up were analyzed.
Small-field output factor measurements are traditionally very difficult because of steep dose gradients, loss of lateral electronic equilibrium, and dose volume averaging in finitely sized detectors. Three-dimensional (3D) dosimetry is ideal for measuring small output factors and avoids many of these potential challenges of point and 2D detectors. PRESAGE 3D polymer dosimeters were used to measure the output factors for the 4 mm and 8 mm collimators of the Leksell Perfexion Gamma Knife radiosurgery treatment system.
View Article and Find Full Text PDFMonte Carlo (MC) modeling of a 6 MV photon beam was used to study the dose perturbation from a titanium rod 5 mm in diameter in various small fields range from 2 × 2 to 5 × 5 cm(2). The results showed that the rod increased the dose to water by ∼6% at the water-rod interface because of electron backscattering and decreased the dose by ∼7% in the shadow of the rod because of photon attenuation. The Pinnacle(3) treatment planning system calculations matched the MC results at the depths more than 1 cm past the rod when the correct titanium density of 4.
View Article and Find Full Text PDFPurpose: To report the use and results of a novel intensity modulated radiotherapy (IMRT)-based technique used for salvage craniospinal irradiation (CSI) in 6 patients who developed neuraxis disease after initial high-dose conformal radiotherapy (RT) to the brain.
Methods And Materials: After Institutional Review Board approval, all patients treated for disseminated leptomeningeal disease with salvage CSI using IMRT with conventional external beam radiotherapy were identified. The medical records and radiotherapy dosimetry were reviewed.
Int J Radiat Oncol Biol Phys
November 2012
Purpose: Spinal stereotactic body radiation therapy (SBRT) continues to emerge as an effective therapeutic approach to spinal metastases; however, treatment planning and delivery remain resource intensive at many centers, which may hamper efficient implementation in clinical practice. We sought to develop a generalizable class solution approach for spinal SBRT treatment planning that would allow confidence that a given plan provides optimal target coverage, reduce integral dose, and maximize planning efficiency.
Methods And Materials: We examined 91 patients treated with spinal SBRT at our institution.
Background: Spinal stereotactic body radiation therapy (SBRT) is increasingly used to manage spinal metastases, yet the technique's effectiveness in controlling the symptom burden of spinal metastases has not been well described. We investigated the clinical benefit of SBRT for managing spinal metastases and reducing cancer-related symptoms.
Methods: 149 patients with mechanically stable, non-cord-compressing spinal metastases (166 lesions) were given SBRT in a phase 1-2 study.
Purpose: The purpose of this work was to clarify the interactions between the parameters used in the γ index with the surface-based distance method, which itself can be viewed as a generalized version of the γ index. The examined parameters included the distance to agreement (DTA)/dose difference (DD) criteria, the percentage used as a passing criterion, and the passing percentage for given DTA/DD criteria. The specific aims of our work were (1) to understand the relationships between the parameters used in the γ index, (2) to determine the detection limit, or the minimum detectable error, of the γ index with a given set of parameters, and (3) to establish a procedure to determine parameters that are consistent with the capacity of an IMRT QA system.
View Article and Find Full Text PDFA quality assurance (QA) procedure was developed to evaluate the congruence between the cone-beam computed tomography (CBCT) image center and the radiation isocenter on a Varian Trilogy linac. In contrast to the published QA procedures, this method did not require a ball bearing (BB) phantom to be placed exactly at the radiation isocenter through precalibrated room lasers or light field crosshairs. The only requirement was that the BB phantom be in a stationary position near the radiation isocenter during the image acquisition process.
View Article and Find Full Text PDFNarrow beams are extensively used in stereotactic radiosurgery. The accuracy of treatment planning dose calculation depends largely on how well the dosimetric data are measured during the machine commissioning. Narrow beams are characterized by the lack of lateral electronic equilibrium.
View Article and Find Full Text PDFWe present a technique--based on the Lutz, Winston, and Maleki test used in stereotactic linear accelerator radiosurgery--for verifying whether proton beams are being delivered within the required spatial coincidence with the gantry mechanical isocenter. Our procedure uses a proton beam that is collimated by a circular aperture at its central axis and is then intercepted by a small steel sphere rigidly supported by the patient couch. A laser tracker measurement system and a correction algorithm for couch position assures precise positioning of the steel sphere at the mechanical isocenter of the gantry.
View Article and Find Full Text PDF