Background: The aim of this study was to compare the recovery of three putative periodontal pathogens from periodontal lesions in samples using paper points inserted to different depths of the lesions.
Methods: Twenty 6-8 mm deep periodontal lesions with bleeding on probing were studied. Microbial samples were obtained using paper points inserted to three different depths of the lesions: orifice of lesion; 2 mm into the lesion; and to the base of lesion.
Pulp and periradicular diseases are of microbial origin. To effectively clean the root canal system a disinfecting agent must be able to penetrate into difficult-to-reach areas and kill microorganisms with minimal damage to the host tissues. The purpose of this investigation was to test the ability of a mixture of a tetracycline isomer, an acid, and a detergent (MTAD) to kill Enterococcus faecalis and compare its efficacy to that of sodium hypochlorite (NaOCl) and ethylene diamine tetraacetic acid (EDTA).
View Article and Find Full Text PDFThe H238 tumor cells are Herpes simplex virus type 2-transformed BALB/c mouse fibroblasts that constitutively express transforming growth factor (TGF-beta1). TGF-beta can diminish immune capacity, whereas interleukin 2 (IL-2) is stimulatory to the immune system and can counteract the negative effects of TGF-beta1. The H238-BALB/c system provides a syngeneic model to evaluate new strategies with the potential to ameliorate tumor-induced immune depression.
View Article and Find Full Text PDFBackground: This study evaluated five chemical disinfectants to compare their abilities to improve dental unit waterline quality and assess their effects, if any, on the biofilm layer.
Methods: Sixty new dental units, with a closed-circuit water system, were used to compare microbial levels in DUWLs treated with five antimicrobials: Listerine, Bio 2000, Rembrandt, Dentosept, and sodium fluoride to a control group of sterile distilled water alone over a six-week period. For all units, the waterlines were filled with solution, left overnight, and then flushed for 30 seconds with sterile distilled water the following morning prior to patient treatment.
Background: The maximum recommended level of microbial contamination of water from dental unit waterlines (DUWL) is 200 colony-forming units per milliliter (CFU/mL). This article addresses the importance of water selection in achieving that standard.
Methods: Microbial contamination in water samples from 75 new dental units, with a closed-circuit water system, were compared using combinations of tap water and sterile distilled water with and without two chemical disinfectants (bleach and 0.
Mineral trioxide aggregate (MTA) has been shown to possess excellent sealing ability when tested with dye, bacteria, and a fluid filtration technique. Endotoxin, a component of the cell wall of Gram-negative bacteria, has been proposed to play a role in the pathogenesis of periradicular lesions. This study used a modified Limulus Amebocyte Lysate test for the presence of endotoxin as a tracer and compared the sealing ability of Super-EBA, IRM, amalgam, and MTA.
View Article and Find Full Text PDF