This article explores the concept of external magnetic control for vine robots to enable their high curvature steering and navigation for use in endoluminal applications. Vine robots, inspired by natural growth and locomotion strategies, present unique shape adaptation capabilities that allow passive deformation around obstacles. However, without additional steering mechanisms, they lack the ability to actively select the desired direction of growth.
View Article and Find Full Text PDFObjectives: Fresh-frozen allograft is the gold-standard bone graft material used during revision hip arthroplasty. However, new technology has been developed to manufacture decellularised bone with potentially better graft incorporation. As these grafts cost more to manufacture, the aim of this cost-effectiveness study was to estimate whether the potential health benefit of decellularised bone allograft outweighs their increased cost.
View Article and Find Full Text PDFWe propose an endoscopic image mosaicking algorithm that is robust to light conditioning changes, specular reflections, and feature-less scenes. These conditions are especially common in minimally invasive surgery where the light source moves with the camera to dynamically illuminate close range scenes. This makes it difficult for a single image registration method to robustly track camera motion and then generate consistent mosaics of the expanded surgical scene across different and heterogeneous environments.
View Article and Find Full Text PDFDriven by the aim of realizing functional robotic systems at the milli- and submillimetre scale for biomedical applications, the area of magnetically driven soft devices has received significant recent attention. This has resulted in a new generation of magnetically controlled soft robots with patterns of embedded, programmable domains throughout their structures. This type of programmable magnetic profiling equips magnetic soft robots with shape programmable memory and can be achieved through the distribution of discrete domains (voxels) with variable magnetic densities and magnetization directions.
View Article and Find Full Text PDFThe opportunity to create different patterns of magnetic nanoparticles on surfaces is highly desirable across many technological and biomedical applications. In this paper, this ability is demonstrated for the first time using a computer-controlled aerosol jet printing (AJP) technology. AJP is an emerging digitally driven, non-contact and mask-less printing process which has distinguishing advantages over other patterning technologies as it offers high-resolution and versatile direct-write deposition of a wide range of materials onto a variety of substrates.
View Article and Find Full Text PDFUltrasound accelerates healing in fractured bone; however, the mechanisms responsible are poorly understood. Experimental setups and ultrasound exposures vary or are not adequately characterized across studies, resulting in inter-study variation and difficulty in concluding biological effects. This study investigated experimental variability introduced through the cell culture platform used.
View Article and Find Full Text PDFDespite increasing interest in minimally invasive surgical techniques and related developments in flexible endoscopes and catheters, follow-the-leader motion remains elusive. Following the path of least resistance through a tortuous and potentially delicate environment without relying on interaction with the surrounding anatomy requires the control of many degrees of freedom. This typically results in large-diameter instruments.
View Article and Find Full Text PDFThe growing interest in soft robotics has resulted in an increased demand for accurate and reliable material modelling. As soft robots experience high deformations, highly nonlinear behavior is possible. Several analytical models that are able to capture this nonlinear behavior have been proposed, however, accurately calibrating them for specific materials and applications can be challenging.
View Article and Find Full Text PDFContinuum manipulators, inspired by nature, have drawn significant interest within the robotics community. They can facilitate motion within complex environments where traditional rigid robots may be ineffective, while maintaining a reasonable degree of precision. Soft continuum manipulators have emerged as a growing subfield of continuum robotics, with promise for applications requiring high compliance, including certain medical procedures.
View Article and Find Full Text PDFSoft continuum manipulators have the potential to replace traditional surgical catheters; offering greater dexterity with access to previously unfeasible locations for a wide range of interventions including neurological and cardiovascular. Magnetically actuated catheters are of particular interest due to their potential for miniaturization and remote control. Challenges around the operation of these catheters exist however, and one of these occurs when the angle between the actuating field and the local magnetization vector of the catheter exceeds 90°.
View Article and Find Full Text PDFSoft pneumatic actuators have been explored for endoscopic applications, but challenges in fabricating complex geometry with desirable dimensions and compliance remain. The addition of an endoscopic camera or tool channel is generally not possible without significant change in the diameter of the actuator. Radial expansion and ballooning of actuator walls during bending is undesirable for endoscopic applications.
View Article and Find Full Text PDFFabrication of soft pneumatic bending actuators typically involves multiple steps to accommodate the formation of complex internal geometry and the alignment and bonding between soft and inextensible materials. The complexity of these processes intensifies when applied to multi-chamber and small-scale (~10 mm diameter) designs, resulting in poor repeatability. Designs regularly rely on combining multiple prefabricated single chamber actuators or are limited to simple (fixed cross-section) internal chamber geometry, which can result in excessive ballooning and reduced bending efficiency, compelling the addition of constraining materials.
View Article and Find Full Text PDFBackground: Traditional flexible endoscopes are sophisticated medical devices that require frequent and expensive maintenance. Therefore, their implementation within low-income and rural regions is challenging due to their high cost, complex sterilization process and poor portability.
Aims: This paper aims to develop an endoscopic platform that is low-cost, disposable and portable, with the primary goal of reducing gastric cancer-related mortality among low- and middle-income communities through wider access to regular screening programs.
IEEE ASME Trans Mechatron
April 2020
With significant research focused on integrating robotics into medical devices, sanitary control of pressurizing fluids in a precise, accurate and customizable way is highly desirable. Current sanitary flow control methods include pinch valves which clamp the pressure line locally to restrict fluid flow; resulting in damage and variable flow characteristics over time. This paper presents a sanitary compression valve based on an eccentric clamping mechanism.
View Article and Find Full Text PDFContinuum manipulators are flexible robots which undergo continuous deformation as they are actuated. To describe the elastic deformation of such robots, kinematic models have been developed and successfully applied to a large variety of designs and to various levels of constitutive stiffness. Independent of the design, kinematic models need to be calibrated to best describe the deformation of the manipulator.
View Article and Find Full Text PDFIEEE Trans Biomed Eng
November 2018
Objective: This paper introduces a methodology to design intuitive, low-cost, and portable devices for visual inspection of the upper gastrointestinal tract.
Methods: The proposed approach mechanically couples a multi-backbone continuum structure, as the user interface, and a parallel bellows actuator, as the endoscopic tip. Analytical modeling techniques derived from continuum robotics were adopted to describe the endoscopic tip motion from user input, accounting for variations in component size and pneumatic compressibility.
Objective: This work presents a method to assess and prevent tissue trauma in real-time during surgery.
Background: Tissue trauma occurs routinely during laparoscopic surgery with potentially severe consequences. As such, it is crucial that a surgeon is able to regulate the pressure exerted by surgical instruments.
Annu Int Conf IEEE Eng Med Biol Soc
August 2015
Electrochemical and electrical characteristics have the potential to help differentiate between, and assess the health state of, different biological tissues. However, measurement and interpretation of these characteristics is non-trivial. We propose a new DC galvanostatic sensing method for application to laparoscopic cancer surgery.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
August 2015
The assessment of tissue compliance using a handheld tool is an important skill in medical areas such as laparoscopic and dental surgery. The increasing prevalence of virtual reality devices raises the question of whether we can exploit these systems to accelerate the training of compliance discrimination in trainee surgeons. We used a haptic feedback device and stylus to assess the abilities of naïve participants to detect compliance differences with and without knowledge of results (KR) (groups 1 and 2), as well as the abilities of participants who had undergone repetitive training over several days (group 3).
View Article and Find Full Text PDF