The development of pseudotumors is not uncommon with metal-on-metal total hip arthroplasty. Pseudotumors that dissect into the retroperitoneal space can cause symptoms of nerve compression. We describe a case of a 53-year-old male with a metal-on-metal total hip arthroplasty who developed mild symptoms of a femoral nerve neuropathy 6 years postoperatively.
View Article and Find Full Text PDFThe purpose of this study was to determine if cobalt and chromium ion levels can predict soft tissue damage at total hip revision. This study included 90 metal-on-metal total hip patients with preoperative cobalt and chromium ion levels. Tissue damage noted at revision surgery was graded on a 4-point scale.
View Article and Find Full Text PDFUnlabelled: Surgical site infections (SSIs) with Staphylococcus aureus are a recognized adverse event of hip and knee replacements. We evaluated the impact of a program to detect S. aureus nasal carriers before surgery with preoperative decolonization (using mupirocin twice daily for 5 days prior to surgery) of carriers.
View Article and Find Full Text PDFGuidelines recommend thromboprophylaxis for at least 10 days to prevent venous thromboembolism in patients undergoing high-risk orthopedic surgery, such as total hip arthroplasty (THA) or total knee arthroplasty (TKA). Furthermore, the recently updated ACCP guidelines also recommend extending the duration of thromboprophylaxis for 28 to 35 days following THA or hip fracture surgery as the risk for venous thromboembolism persists for up to 3 months after surgery. Extended-duration thromboprophylaxis (up to 6 weeks) with low-molecular-weight heparin is significantly more effective in preventing venous thromboembolism in orthopedic surgery patients than the recommended practice of at least 10 days.
View Article and Find Full Text PDFNormal femoral version contributes to the inherent stability of the hip joint. Abnormal version is found in a variety of hip diseases afflicting children and adults. At the time of reconstruction for end-stage hip disease, maintaining proper femoral version in conjunction with acetabular version allows for hip stability and unimpeded functional range of motion.
View Article and Find Full Text PDFThis investigation prospectively studied a consecutive series of 22 proximally cemented, distal cementless, femoral components with a minimum follow-up time of 24 months. The prosthesis was a titanium, proximally cemented, femoral component with a distal press-fit fluted design. Five hips (23%) developed aseptic mechanical loosening at an average of 46.
View Article and Find Full Text PDFInvestigations into the effects of sterilization on a new biomechanical pressure sensor are necessary before contemplating in vivo use. Ten, designated Experimental, "K-Scan" digital pressure sensor arrays were sterilized with ethylene oxide gas (EtO), and their ability to accurately and reproducibly measure an applied load of 2225 N (500 lb) was assessed. Simultaneously, 10 un-sterilized sensor arrays, designated Control, were assessed.
View Article and Find Full Text PDF