A fluorescence resonance energy transfer (FRET)-based microbubble contrast agent system was designed to experimentally demonstrate the concept of ultrasound-modulated fluorescence (UMF). Microbubbles were simultaneously labeled with donor and acceptor fluorophores on the surface to minimize self-quenching and maximize FRET. In response to ultrasound, the quenching efficiency was greatly modulated by changing the distance between the donor and acceptor molecules through microbubble size oscillations.
View Article and Find Full Text PDFAlternative extrapulmonary oxygenation technologies are needed to treat patients suffering from severe hypoxemia refractory to mechanical ventilation. We previously demonstrated that peritoneal microbubble oxygenation (PMO), in which phospholipid-coated oxygen microbubbles (OMBs) are delivered into the peritoneal cavity, can successfully oxygenate rats suffering from a right pneumothorax. This study addressed the need to scale up the procedure to a larger animal with a splanchnic cardiac output similar to humans.
View Article and Find Full Text PDFUltrasound-modulated fluorescence (UMF) imaging has been proposed to provide fluorescent contrast while maintaining ultrasound resolution in an optical-scattering medium (such as biological tissue). The major challenge is to extract the weakly modulated fluorescent signal from a bright and unmodulated background. UMF was experimentally demonstrated based on fluorophore-labeled microbubble contrast agents.
View Article and Find Full Text PDFSevere hypoxemia refractory to pulmonary mechanical ventilation remains life-threatening in critically ill patients. Peritoneal ventilation has long been desired for extrapulmonary oxygenation owing to easy access of the peritoneal cavity for catheterization and the relative safety compared to an extracorporeal circuit. Unfortunately, prior attempts involving direct oxygen ventilation or aqueous perfusates of fluorocarbons or hemoglobin carriers have failed, leading many researchers to abandon the method.
View Article and Find Full Text PDFFocused ultrasound, in the presence of microbubbles, has been used non-invasively to induce reversible blood-brain barrier (BBB) opening in both rodents and non-human primates. This study was aimed at identifying the dependence of BBB opening properties on polydisperse microbubble (all clinically approved microbubbles are polydisperse) type and distribution by using a clinically approved ultrasound contrast agent (Definity microbubbles) and in-house prepared polydisperse (IHP) microbubbles in mice. A total of 18 C57 BL/6 mice (n = 3) were used in this study, and each mouse was injected with either Definity or IHP microbubbles via the tail vein.
View Article and Find Full Text PDFGas-filled microbubbles are potentially useful theranostic agents for magnetic resonance imaging-guided focused ultrasound surgery (MRIgFUS). Previously, MRI at 9.4 T was used to measure the contrast properties of lipid-coated microbubbles with gadolinium (Gd(III)) bound to lipid headgroups, which revealed that the longitudinal molar relaxivity (r(1)) increased after microbubble fragmentation.
View Article and Find Full Text PDFThe activation of bubbles by an acoustic field has been shown to temporarily open the blood-brain barrier (BBB), but the trigger cause responsible for the physiological effects involved in the process of BBB opening remains unknown. Here, the trigger cause (i.e.
View Article and Find Full Text PDFWe have synthesized a biomaterial consisting of Gd(III) ions chelated to lipid-coated, size-selected microbubbles for utility in both magnetic resonance and ultrasound imaging. The macrocyclic ligand DOTA-NHS was bound to PE headgroups on the lipid shell of pre-synthesized microbubbles. Gd(III) was then chelated to DOTA on the microbubble shell.
View Article and Find Full Text PDFThe therapeutic efficacy of neurological agents is severely limited, because large compounds do not cross the blood-brain barrier (BBB). Focused ultrasound (FUS) sonication in the presence of microbubbles has been shown to temporarily open the BBB, allowing systemically administered agents into the brain. Until now, polydispersed microbubbles (1-10 microm in diameter) were used, and, therefore, the bubble sizes better suited for inducing the opening remain unknown.
View Article and Find Full Text PDFMicrobubbles used as contrast agents for ultrasound imaging, vectors for targeted drug delivery and vehicles for metabolic gas transport require better size control for improved performance. Mechanical agitation is the only method currently available to produce microbubbles in sufficient yields for biomedical applications, but the emulsions tend to be polydisperse. Herein, we describe a study to generate lipid-coated, perfluorobutane-filled microbubbles and isolate their size fractions based on migration in a centrifugal field.
View Article and Find Full Text PDF