Valuable quantitative information could be obtained from strongly overlapped chromatographic profiles of two enantiomers by using proper chemometric methods. Complete separation profiles where the peaks are fully resolved are difficult to achieve in chiral separation methods, and this becomes a particularly severe problem in case that the analyst needs to measure the chiral purity, i.e.
View Article and Find Full Text PDFThe association constants of several volatile enantiomers with octakis(3-O-butanoyl-2,6-di-O-pentyl)-γ-cyclodextrin at temperatures between 50 and 100 °C were measured by gas-liquid chromatography using capillary columns coated with different amounts of chiral selector dissolved in polysiloxane OV-1701 and prepared with a precisely determined phase ratio. Simple expressions were deduced to estimate the apparent distribution constants from accurate hold-up and retention times along with that known phase ratio at each temperature. The enantiomer-chiral selector association constants were then calculated from the linear regression of the apparent constants as a function of the chiral selector concentration.
View Article and Find Full Text PDFA chiral anion-exchanger stationary phase based on cinchonidine (CD) was developed. Two columns were packed with and without endcapping (EC) treatment (CD-chiral stationary phase[CD-CSP(EC)] and [CD-CSP], respectively) and studied for their ability to separate N-2,4-dinitrophenyl α-amino acids (DNP-amino acids) enantiomers over a temperature range of 10-40 °C with a hydro-organic buffer mobile phase. The more hydrophobic, endcapped stationary phase showed significantly larger retentive capacity than the non-endcapped one.
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
December 2012
In this report, we demonstrate how chiral liquid chromatography combined with multivariate chemometric techniques, specifically unfolded-partial least-squares regression (U-PLS), provides a powerful analytical methodology. Using U-PLS, strongly overlapped enantiomer profiles in a sample could be successfully processed and enantiomeric purity could be accurately determined without requiring baseline enantioresolution between peaks. The samples were partially enantioseparated with a permethyl-β-cyclodextrin chiral column under reversed-phase conditions.
View Article and Find Full Text PDFWe developed an improved reversed-phase high-performance liquid chromatography (RPLC) assay for the rapid separation and determination of the 2-hydroxyethidium ion. The 2-hydroxyethidium ion is the specific product of the redox reaction between hydroethidine with superoxide radical. High resolution between the chromatographic bands corresponding to ethidium and 2-hydroxyethidium ions was achieved within a practicable analysis time.
View Article and Find Full Text PDFRecent developments in HPLC methods have focused on various strategies in order to increase the speed of analysis. One area of impressive growing is column technology. Today, analytical methods that propose the use of short columns packed with sub-2 μm particles installed in ultra high-pressure LC instruments are not uncommon.
View Article and Find Full Text PDFThis paper reports the study of poly(oxyethylene) as a solvent for heptakis(2,3,6-tri-O-methyl)-beta-cyclodextrin (PM-beta-CD) and the potential of these mixtures for constructing enantioselective gas chromatography columns. Enantioseparations of volatile racemic mixtures using capillaries coated with 10-50% PM-beta-CD diluted in Carbowax 20M were evaluated. The influence of the polymer type on retention, separation and reproducibility over a period of time is critically discussed.
View Article and Find Full Text PDF