. Precise identification of pancreatic tumors is challenging for radiotherapy planning due to the tumor's anatomical variability and poor visualization on 3D cross-sectional imaging. Low extracellular volume fraction (ECVf) correlates with poor vasculature uptake and possible necrosis or hypoxia in pancreatic tumors.
View Article and Find Full Text PDFPurpose: We developed a deep neural network that queries the lung computed tomography-derived feature space to identify radiation sensitivity parameters that can predict treatment failures and hence guide the individualization of radiotherapy dose. In this article, we examine the transportability of this model across health systems.
Methods: This multicenter cohort-based registry included 1,120 patients with cancer in the lung treated with stereotactic body radiotherapy.
Automatic contouring algorithms may streamline clinical workflows by reducing normal organ-at-risk (OAR) contouring time. Here we report the first comprehensive quantitative and qualitative evaluation, along with time savings assessment for a prototype deep learning segmentation algorithm from Siemens Healthineers. The accuracy of contours generated by the prototype were evaluated quantitatively using the Sorensen-Dice coefficient (Dice), Jaccard index (JC), and Hausdorff distance (Haus).
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
March 2023
Purpose: Dual-energy computed tomography (DECT) data can be used to calculate the extracellular volume fraction (ECVf) in tumors, which has been correlated with treatment outcome. This study sought to find a correlation between ECVf and treatment response as measured by the change in cancer antigen (CA) 19 to 9 during chemoradiation therapy (CRT) for pancreatic cancer.
Methods And Materials: Dual-energy CT data acquired during the late arterial contrast phase in the standard radiation therapy simulation on a dual-source DECT simulator for 25 patients with pancreatic cancer, along with their CA19-9 and hematocrit data, were analyzed.
Introduction: Deep learning (DL) models that use medical images to predict clinical outcomes are poised for clinical translation. For tumors that reside in organs that move, however, the impact of motion (i.e.
View Article and Find Full Text PDFPurpose: The dual-energy CT (DECT) LiverVNC application class in the Siemens Syngo.via software has been used to perform non-iodine material decompositions. However, the LiverVNC application is designed with an optional size-specific calibration based on iodine measurements.
View Article and Find Full Text PDFPurpose: Radiation therapy (RT) planning frequently utilizes contrast-enhanced CT. However, dose calculations should not be performed on a contrast-enhanced CT because the patient will not receive bolus during treatment. It is typical to acquire CT twice during RT simulation: once before injection of bolus and once after.
View Article and Find Full Text PDFHounsfield Units (HU) are used clinically in differentiating tissue types in a reconstructed CT image, and therefore the HU accuracy of a system is important, especially when using multiple sources, novel detector and non-traditional trajectories. Dedicated clinical breast CT (BCT) systems therefore should be similarly evaluated. In this study, uniform cylindrical phantoms filled with various uniform density fluids were used to characterize differences in HU values between simple circular and complex 3D (saddle) orbits.
View Article and Find Full Text PDFIntroduction: Contrast-induced nephropathy (CIN) following percutaneous coronary intervention (PCI) is associated with adverse outcomes; however, there are scarce data comparing clinical outcomes of post-PCI CIN in ST elevation myocardial infarction (STEMI) patients with and without chronic kidney disease (CKD). We sought to assess the incidence, clinical predictors, and short-term and long-term clinical outcomes of post-PCI CIN in STEMI patients with and without CKD.
Methods: We performed a retrospective observational cohort study involving 554 patients who underwent PCI for STEMI from February 2010 to November 2013.
Stand-alone cone beam computed tomography (CT) and single-photon emission computed tomography (SPECT) systems capable of complex acquisition trajectories have previously been developed for breast imaging. Fully three-dimensional (3-D) motions of SPECT systems provide views into the chest wall and throughout the entire volume. The polar tilting capability of the CBCT system has shown improvement in sampling close to the chest wall, while eliminating cone beam artifacts.
View Article and Find Full Text PDFDeglutition syncope, also known as swallow syncope, is a neurally mediated reflex syndrome. The common intervention of the heart, esophagus, and stomach by the vagus nerve is central to its pathogenesis, whereby swallowing causes inhibition of the cardiac conduction system. It is most commonly associated with disorders of the esophagus, both organic and functional.
View Article and Find Full Text PDFObjective: The purpose of this study was to utilize a dedicated breast CT system using a 2D beam stop array to physically evaluate the scatter to primary ratios (SPRs) of different geometric phantoms and prospectively acquired clinical patient data.
Methods: Including clinically unrealizable compositions of 100% glandular and 100% fat, projection images were acquired using three geometrically different phantoms filled with fluids simulating breast tissue. The beam stop array method was used for measuring scatter in projection space, and creating the scatter corrected primary images.
Unileaflet mitral valve is the rarest of the congenital mitral valve anomalies and is usually life threatening in infancy due to severe mitral regurgitation (MR). In most asymptomatic individuals, it is mostly due to hypoplastic posterior mitral leaflet. We present a 22-year-old male with palpitations, who was found to have an echocardiogram revealing an elongated anterior mitral valve leaflet with severely hypoplastic posterior mitral valve leaflet appearing as a unileaflet mitral valve without MR.
View Article and Find Full Text PDFDevice based closure of the left atrial appendage (LAA) has emerged as a viable approach for stroke prevention in atrial fibrillation (AF) patients with contraindications to chronic oral anticoagulation. One of the most feared complications is device related thrombus formation. We present a 66-year-old male with chronic AF who developed a life-threatening intracranial bleed on oral anti-coagulation.
View Article and Find Full Text PDFAcute generalized exanthematous pustulosis (AGEP) is a rare cutaneous adverse reaction characterized by acute sterile pustular eruptions, mostly induced by medications. Antibiotics are the most commonly implicated drugs; however, there have only been two previous reports of vancomycin-induced AGEP in the literature. In this case, we present the clinical course of a 56-year-old man who was admitted to the intensive care unit with an unusually severe form of AGEP mimicking septic shock, which developed after the recent use of vancomycin.
View Article and Find Full Text PDFPurpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient's chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits.
Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements.
A pilot study is underway to quantify in vivo the uptake and distribution of Tc-99m Sestamibi in subjects without previous history of breast cancer using a dedicated SPECT-CT breast imaging system. Subjects undergoing diagnostic parathyroid imaging studies were consented and imaged as part of this IRB-approved breast imaging study. For each of the seven subjects, one randomly selected breast was imaged prone-pendant using the dedicated, compact breast SPECT-CT system underneath the shielded patient support.
View Article and Find Full Text PDFWith a dedicated breast CT system using a quasi-monochromatic x-ray source and flat-panel digital detector, the 2D and 3D scatter to primary ratios (SPR) of various geometric phantoms having different densities were characterized in detail. Projections were acquired using geometric and anthropomorphic breast phantoms. Each phantom was filled with 700ml of 5 different water-methanol concentrations to simulate effective boundary densities of breast compositions from 100% glandular (1.
View Article and Find Full Text PDFProc SPIE Int Soc Opt Eng
March 2011
The goal of this study was to characterize the image quality of our dedicated, quasi-monochromatic spectrum, cone beam breast imaging system under scatter corrected and non-scatter corrected conditions for a variety of breast compositions. CT projections were acquired of a breast phantom containing two concentric sets of acrylic spheres that varied in size (1-8mm) based on their polar position. The breast phantom was filled with 3 different concentrations of methanol and water, simulating a range of breast densities (0.
View Article and Find Full Text PDF