Small-sized stainless steel hand files are conventionally employed in root canal treatment procedures for canal scouting and for glide path establishment, owing to their superior flexibility and proficiency in navigating confined spaces. Given the diversity of brands available in the market, there exists potential variability in their physical characteristics, thereby influencing clinical performance. Consequently, this study aims to conduct a comparative analysis of the design, metallurgy, and mechanical characteristics among seven stainless steel hand file brands across ISO sizes 06, 08, and 10.
View Article and Find Full Text PDFTo establish a glide path, smaller files (up to size 0.15) with tapers of 2% are commonly used as pathfinding files. They pre-shape the root canal space before transitioning to larger taper endodontic instruments, aiming to prevent procedural errors.
View Article and Find Full Text PDFChanges in the properties of resin-based polymers exposed to the oral environment can emerge when chlorhexidine (CHX) is incorporated to develop bioactive systems for treating denture stomatitis. Three reline resins loaded with CHX were prepared: 2.5 wt% in Kooliner (K), 5 wt% in Ufi Gel Hard (UFI), and Probase Cold (PC).
View Article and Find Full Text PDFThe most commonly used material in dental implants and their abutments is titanium. Zirconia is a more aesthetic alternative to titanium abutments; however, it is much harder. There are concerns that zirconia could damage the surface of the implant over time, especially in less stable connections.
View Article and Find Full Text PDFStatement Of Problem: The fit of removable partial denture frameworks should be assessed to optimize clinical adaptation. Potential discrepancies between framework and supporting structures are typically precisely measured with negative subtracts and high-resolution equipment. The growth of computer-aided engineering technology allows the development of new methods for the direct evaluation of discrepancies.
View Article and Find Full Text PDFThe high recurrence rate of common denture stomatitis after antifungal treatment is still concerning. This condition is caused by low patient compliance and incomplete local elimination of the main etiological factor - Candida albicans, often associated with other microorganisms, such as Streptococcus species. Impregnating denture materials with antimicrobials for local delivery is a strategy that can overcome the side effects and improve the efficacy of conventional treatments (topical and/or systemic).
View Article and Find Full Text PDFIn dentistry, the use of biomaterial-based drug delivery systems (DDS) aiming the release of the active compounds directly to the site of action is slowly getting more awareness among the scientific and medical community. Emerging technologies including nanotechnological platforms are offering novel approaches, but the majority are still in the proof-of-concept stage. This study critically reviews the potential use of DDS in anesthesiology, oral diseases, cariology, restorative dentistry, periodontics, endodontics, implantology, fixed and removable prosthodontics, and orthodontics with a special focus on infections.
View Article and Find Full Text PDFCoronavirus disease 2019 (COVID-19), a viral disease declared a pandemic by the World Health Organization (WHO) in March 2020, has posed great changes to many sectors of society across the globe. Its virulence and rapid dissemination have forced the adoption of strict public health measures in most countries, which, collaterally, resulted in economic hardship. This article is the first in a series of 3 that aims to contextualise the clinical impact of COVID-19 for the dental profession.
View Article and Find Full Text PDFCollagen cleavage by matrix metalloproteinase (MMP) is considered a major cause of dental resins long term failure. Most MMP inhibitors display significant toxicity and are unsuitable for dental resins' applications. Here we report a study of a new class of inhibitors that display the unique property of being co-polymerizable with other vinyl compounds present in commercial dental resins, limiting their release and potential toxicity.
View Article and Find Full Text PDFPurpose: To evaluate the influence of application protocol on the shear bond strength (SBS) and nanoleakage of simplified adhesives over 18 months.
Materials And Methods: 810 dentin slices were obtained from 405 caries-free human molars. They were randomly assigned to 54 experimental groups resulting from the combination of "adhesive" (Adper Scotchbond 1XT [S1XT], Solobond M [SM], Scotchbond Universal Adhesive in etch-and-rinse mode [SUER] and self-etch mode [SUSE], Adper Easy Bond [EB], Clearfil S3 Bond Plus [CS3]), "application protocol" (manufacturer's instructions [MI], two extra layers of adhesive [EL], hydrophobic resin layer [HL]), and "aging time" (24 h [24H], 6 months [6M], and 18 months [18M] in water).
Matrix metalloproteinases are enzymes that degrade the extracellular matrix. They have different substrates but similar structural organization. Matrix metalloproteinases are involved in many physiological and pathological processes and there is a need to develop inhibitors for these enzymes in order to modulate the degradation of the extracellular matrix (ECM).
View Article and Find Full Text PDFStatement Of Problem: Saliva contamination has been shown to decrease bonding to zirconia. Adopting a less contamination-sensitive cement system may be an alternative to decontamination.
Purpose: The purpose of this in vitro study was to assess the ability of different primer/cement systems to promote a durable bond to zirconia after saliva contamination.
Although resin-bonded fixed dental prostheses (RBFDPs) were developed almost 40 years ago, their implementation in clinical practice did not achieve success due to biomechanical failures of the restorative materials. Nowadays, the evolution of ceramic materials and bonding procedures has allowed for the revival of the dental prosthesis. Zirconia is the dental ceramic with the highest flexural strength under compression.
View Article and Find Full Text PDFAims: To evaluate the influence of mechanical surface treatment and chemical primer application on the composite shear bond strength to zirconia.
Methods: Eighty blocks of Lava Frame Zirconia were randomly assigned to the experimental groups, according to the several possible combinations between mechanical (untreated/aluminum oxide sandblast) and chemical treatment (no primer/Monobond Plus/Experimental Zirkon-Primer/Z-Prime Plus) (n=10). Adhesive system and composite resin were then applied, and samples were thermal cycled (5°C-55°C, 500 cycles).
Statement Of Problem: More information is needed on the efficacy of the new universal adhesives and on the best 10-methacryloyloxydecyl dihydrogen phosphate- (MDP)-containing primer protocol to promote adhesion to zirconia.
Purpose: The aim of this study was to evaluate the influence of 2 new multimode MDP-containing adhesives and several application protocols of a zirconia primer on the shear bond strength (SBS) of composite resin to zirconia.
Material And Methods: Sixty zirconia (3Y-TZP) blocks were abraded (50 μm Al2O3) and divided into 6 experimental groups (n=10): one Z-Prime Plus coat without light polymerization; one Z-Prime Plus light-polymerized coat; two Z-Prime Plus coats without light polymerization; two Z-Prime Plus light-polymerized coats; All-Bond Universal; and ScotchBond Universal Adhesive.
J Appl Biomater Funct Mater
September 2013
Purpose: The aim of this work was to assess the shear bond strength (SBS) between a composite resin and dentin, promoted by two dental adhesive systems (one-step self-etching adhesive Easy Bond [3M ESPE], and two-step etch-and-rinse adhesive Scotchbond 1XT [3M ESPE]) with different application protocols (per manufacturer's instruction (control group); with one to four additional adhesive layers; or with an extra hydrophobic adhesive layer).
Methods: Proximal enamel was removed from ninety caries-free human molars to obtain two dentin discs per tooth, which were randomly assigned to twelve experimental groups (n=15). After adhesion protocol, the composite resin (Filtek Z250 [3M ESPE]) was applied.