Background: Recent approval of transcatheter aortic valve replacement (TAVR) in patients at lower risk profiles has resulted in a real-world expansion in patients with bicuspid aortic valves (BAV), otherwise excluded from trials comparing TAVR with surgical aortic valve replacement (SAVR). This study compared perioperative and longitudinal outcomes between BAV patients undergoing TAVR vs SAVR.
Methods: Using the United States Centers for Medicare and Medicaid Services inpatient claims database, we evaluated all beneficiaries with BAV undergoing isolated SAVR or TAVR (2018-2022).
J Soc Cardiovasc Angiogr Interv
September 2024
Background: Current evidence supports equipoise between surgical aortic valve replacement (AVR) and transcatheter AVR (TAVR) for the management of symptomatic severe aortic stenosis (AS). The optimal interventional management for lower-risk patients is controversial. Minimally invasive robotic AVR (RAVR) was developed as a potential option.
View Article and Find Full Text PDFJ Soc Cardiovasc Angiogr Interv
March 2024
Transcatheter atrial shunt therapies, designed to dynamically lower left atrial (LA) pressure by shunting blood into the larger reservoir of the right atrium and central veins, have been developed as a novel treatment for heart failure (HF) over the past 10+ years. Several atrial shunt devices and procedures are currently in development with several pivotal randomized clinical trials (RCT) underway; however, only 2 sham-controlled RCT (both with the Atrial Shunt Device [Corvia Medical] in HF with EF ≥ 40%) have been reported thus far; a mechanistic RCT (n = 44) that demonstrated a reduction in exercise LA pressure at 1 month and a pivotal RCT (n = 626) that was neutral with no difference in outcomes or health status between shunt and sham groups. Subsequent analyses of the single completed pivotal RCT found that peak exercise pulmonary vascular resistance <1.
View Article and Find Full Text PDFContext: Left atrial appendage closure (LAAC) was developed as a novel stroke prevention alternative for patients with atrial fibrillation, particularly for those not suitable for long-term oral anticoagulant therapy. Traditionally, general anesthesia (GA) has been more commonly used primarily due to the necessity of transesophageal echocardiography.
Aims: Compare trends of monitored anesthesia care (MAC) versus GA for percutaneous transcatheter LAAC with endocardial implant and assess for independent variables associated with primary anesthetic choice.
Objective: Recent approval of transcatheter aortic valve replacement (TAVR) in patients at low surgical risk has resulted in a rapid real-world expansion of TAVR in patients not otherwise examined in recent low-risk trials. We sought to evaluate the outcomes of surgical aortic valve replacement (SAVR) versus TAVR in low-risk Medicare beneficiaries.
Methods: Using the US Centers for Medicare and Medicaid Services claims database, we evaluated all beneficiaries undergoing isolated SAVR (n = 33,210) or TAVR (n = 77,885) (2018-2020).
Background: Societal guidelines support atrial fibrillation (AF) treatment during surgical aortic valve replacement (SAVR). Recently, many patients with AF at low to intermediate risk are managed by transcatheter aortic valve replacement (TAVR). Therefore, we evaluated longitudinal outcomes in these populations.
View Article and Find Full Text PDFIntroduction: Mitral valve stenosis (MS) can be concomitantly present in patients undergoing Transcatheter Aortic Valve Implantation (TAVI). Some studies have reported up to one-fifth of patients who underwent TAVI also have MS. The relationship between mitral stenosis and TAVI has led to concerns regarding increased adverse cardiac outcomes during and after the procedure.
View Article and Find Full Text PDFPlanar antennas have become an integral component in modern biomedical instruments owing to their compact structure, cost effectiveness, and light weight. These antennas are crucial in realizing medical systems such as body area networks, remote health monitoring, and microwave imaging systems. Antennas intended for the above applications should be conformal and fabricated using lightweight materials that are suitable for wear on the human body.
View Article and Find Full Text PDFAccording to the Global Burden of Disease Project, the morbidity and mortality of myocarditis continue to be a significant worldwide burden. On October 1, 2015, hospital administrative data started using the International Classification of Diseases (ICD)-10 codes instead of the ICD-9. To our knowledge, nationwide trends of myocarditis have not been studied after this update.
View Article and Find Full Text PDFJ Soc Cardiovasc Angiogr Interv
May 2023
Patent foramen ovale (PFO) occluder device has been shown to reduce the chance of recurrent stroke. Per guidelines, stroke is higher in females but procedural efficacy and complications based on sex difference is understudied. The nationwide readmission database (NRD) was used to create sex cohorts using ICD-10 Procedural code for elective PFO occluder device placement performed during the years 2016-2019.
View Article and Find Full Text PDFObjective: Severely calcified coronary stenoses remain a significant challenge during contemporary percutaneous coronary intervention (PCI), often requiring advanced therapies to circumvent suboptimal lesion preparation and major adverse cardiac events (MACEs). Recent reports suggest combined coronary atherectomy and intravascular lithotripsy (IVL) may achieve superior preparation of severely calcified coronary stenoses during PCI. We sought to evaluate the safety and utility of combined orbital atherectomy (OA) and IVL for the modification of coronary artery calcification (CAC) prior to drug-eluting stent (DES) implantation in PCI.
View Article and Find Full Text PDFBackground: Coronary intravascular lithotripsy (IVL) is an emerging therapy for the modification of coronary artery calcification (CAC). Data on its use in several clinical and lesion subsets are limited due to their exclusion from preapproval trials.
Methods: We performed a retrospective review of patients who were excluded from preapproval trials of coronary IVL and underwent CAC modification with the off-label use of a peripheral IVL system.
Severe acute isolated right ventricular failure has limited dedicated percutaneous temporary mechanical circulatory support options, especially after orthotopic heart transplantation. The advent of the Impella RP device provides a newer option, though an absolute contraindication to device placement is thrombus within the right heart. We present a novel case where catheter-based embolectomy was used to evacuate right heart thrombus before Impella RP placement in a patient with severe acute right ventricular failure due to primary graft dysfunction after orthotopic heart transplantation.
View Article and Find Full Text PDFBackground: Structural left atrial and ventricular abnormalities on the electrocardiogram (ECG) and transthoracic echocardiogram (TTE) at the time of ischemic stroke have been associated with morbidity and mortality. Yet, the prognostic impact of the same in embolic stroke of undetermined source (ESUS), a relevant subtype of ischemic stroke with a unique pathophysiology, has not been well studied to date. Our aim was to assess the predictive impact of left atrio-ventricular ECG and TTE abnormalities on one-year hospital readmission after ESUS from an ongoing single center prospective stroke registry in the U.
View Article and Find Full Text PDFBackground/aims: Gastroesophageal reflux (GER) is postulated to play a role in idiopathic pulmonary fibrosis (IPF). However, the value of objective GER measures in predicting IPF disease progression is unclear. We aim to evaluate the association between objective GER measures on multichannel intraluminal impedance and pH (MII-pH) testing and development of poor pulmonary outcomes within 1 year in prelung transplant IPF patients.
View Article and Find Full Text PDFPurpose: Students applying to radiation oncology residency programs complete 1 or more radiation oncology clerkships. This study assesses student experiences and perspectives during radiation oncology clerkships. The impact of didactic components and number of clerkship experiences in relation to confidence in clinical competency and preparation to function as a first-year radiation oncology resident are evaluated.
View Article and Find Full Text PDFBackground & Objectives: Pre-clinical toxicology evaluation of biotechnology products is a challenge to the toxicologist. The present investigation is an attempt to evaluate the safety profile of the first indigenously developed recombinant DNA anti-rabies vaccine [DRV (100 μg)] and combination rabies vaccine [CRV (100 μg DRV and 1.25 IU of cell culture-derived inactivated rabies virus vaccine)], which are intended for clinical use by intramuscular route in Rhesus monkeys.
View Article and Find Full Text PDFProlonged treatment execution time is a concern in CyberKnife robotic radiosurgery. Beam reduction and node reduction technique, and monitor unit optimization methods are adopted to reduce the treatment time. Usage of single collimator in the CyberKnife treatment plan can potentially reduce collimator exchange time.
View Article and Find Full Text PDFThis study addressed the antifouling efficiency of commercially available chlorine at different concentrations (0.5%, 1%, and 2%) and exposure times (0.5 min, 1 min, 5 min, and 15 min).
View Article and Find Full Text PDFBackground: Initial clinical trials from Europe have demonstrated that the administration of bone marrow-derived mononuclear cells (BMCs) may improve left ventricular (LV) function in patients following ST-elevation myocardial infarction (STEMI). However, results from trials performed in the United States have not yet been presented.
Methods: We developed a phase 1, randomized, placebo-controlled, double-blind trial to investigate the effects of BMC administration in patients following STEMI on recovery of LV function using cardiac magnetic resonance imaging (cMRI).
The absence of standard guidelines from National and International regulatory agencies for the safety evaluation of biotechnology products challenges the ingenuity of toxicologists. At present, the development of standard pre-clinical toxicology protocols for such products is on an individual case basis. The present investigation is an attempt to evaluate the safety profile of the first indigenously developed DNA based anti-rabies vaccine in India.
View Article and Find Full Text PDF