Publications by authors named "Jaehyeon Seo"

Background: High-dose-rate (HDR) brachytherapy using Iridium-192 as a radiation source is widely employed in cancer treatment to deliver concentrated radiation doses while minimizing normal tissue exposure. In this treatment, the precision with which the sealed radioisotope source is delivered significantly impacts clinical outcomes.

Purpose: This study aims to evaluate the feasibility of a new four-dimensional (4D) in vivo source tracking and treatment verification system for HDR brachytherapy using a patient-specific approach.

View Article and Find Full Text PDF

Introduction: The purpose of this study was to evaluate a plastic scintillating plate-based beam monitoring system to perform quality assurance (QA) measurements in pencil beam scanning proton beam.

Methods: Single spots and scanned fields were measured with the high-resolution dosimetry system, consisting of a plastic scintillation plate coupled to a camera in a dark box at the isocenter. The measurements were taken at 110-190 MeV beam energies with 30° gantry angle intervals at each energy.

View Article and Find Full Text PDF

Purpose: This study evaluated the properties of a scintillation sheet-based dosimetry system for beam monitoring with high spatial resolution, including the effects of this system on the treatment beam. The dosimetric characteristics and feasibility of this system for clinical use were also evaluated.

Methods: The effects of the dosimetry system on the beam were evaluated by measuring the percentage depth doses, dose profiles, and transmission factors.

View Article and Find Full Text PDF

Introduction: This study describes a simple method of inter-fractional photon beam monitoring to measure the entrance dose of radiation treatment using Gafchromic EBT3 film.

Materials And Methods: The film was placed at the center of a 1-cm thick phantom shaped like a block tray and fixed on the accessory tray of the gantry. The entrance dose was measured following the placement of the film in the accessory tray.

View Article and Find Full Text PDF

Background: Tumor-treating fields (TTFields) therapy is increasingly utilized clinically because of its demonstrated efficacy in cancer treatment. However, the risk of skin burns must still be reduced to improve patient safety and posttreatment quality of life.

Purpose: The purpose of this study was to evaluate the methods of constructing electrode arrays that reduce current density exceeding threshold values, which can cause skin burns during TTFields therapy.

View Article and Find Full Text PDF

Glioblastoma multiforme (GBM), the most common type of brain tumor, is a very aggressive and treatment-refractory cancer, with a 5-year survival rate of approximately 5%. Hyperthermia (HT) and tumor treating fields (TTF) therapy have been used to treat cancer, either alone or in combination with other treatment methods. Both treatments have been reported to increase the efficacy of other treatment techniques and to improve patient prognosis.

View Article and Find Full Text PDF

There are numerous studies recommending fibular groove deepening in the surgical treatment of peroneal tendon dislocation; however, there are some disadvantages to fibular groove deepening procedures. In this study, we evaluated the results of anatomic reattachment of the peroneal retinaculum without fibular groove deepening as a treatment for traumatic peroneal tendon dislocation. Thirty-six patients with recurrent peroneal tendon dislocation, who underwent retinaculum repair without a fibular groove deepening procedure performed by 2 surgeons between March 2004 and March 2017, were enrolled in this study.

View Article and Find Full Text PDF

Purpose: The entrance beam fluence of therapeutic proton scanning beams can be monitored using a gantry-attachable plastic scintillating plate (GAPSP). This study evaluated the clinical application of the GAPSP using a method that measures intensity modulated proton therapy (IMPT) beams for patient treatment.

Methods: IMPT beams for the treatment of nine patients, at sites that included the spine, head and neck, pelvis, and lung, were measured using the GAPSP, composed of an EJ-212 plastic scintillator and a CMOS camera.

View Article and Find Full Text PDF

Background: CaO-SiO-PO-BO bioactive glass ceramic (BGC) is known to chemically bond with bones by forming a hydroxyapatite layer and inducing osteoblastic differentiation. This study was conducted to compare the clinical outcomes, radiographic outcomes, and safety of a CaO-SiO-PO-BO BGC cage in anterior cervical diskectomy and fusion (ACDF) with those of an allograft interbody spacer.

Methods: A total of 63 patients who underwent 2-level ACDF to treat degenerative cervical radiculopathy/myelopathy were reviewed.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to describe a plastic scintillating plate-based gantry-attachable dosimetry system for pencil beam scanning proton therapy to monitor entrance proton beam fluence, and to evaluate the dosimetric characteristics of this system and its feasibility for clinical use.

Methods: The dosimetry system, consisting of a plastic scintillating plate and a CMOS camera, was attached to a dedicated scanning nozzle and scintillation during proton beam irradiation was recorded. Dose distribution was calculated from the accumulated recorded frames.

View Article and Find Full Text PDF

Radiotherapy for the treatment of cancer in companion animals is currently administered by using megavoltage X-ray machines. Because these machines are expensive, most animal hospitals do not perform radiotherapy. This study evaluated the ability of relatively inexpensive kilovoltage X-ray machines to treat companion animals.

View Article and Find Full Text PDF

Aims: This study characterized the pharmacokinetics of ramosetron and compared prophylactic anti-emetic efficacy with that of ondansetron in a large population.

Methods: Fifty-eight patients consented to the pharmacokinetic analysis and were assigned randomly to receive 0.3, 0.

View Article and Find Full Text PDF