Extracorporeal membrane oxygenation (ECMO) support has a high incidence of both bleeding and thrombotic complications. Despite clear differences in patient characteristics and pathologies between veno-venous (VV) and veno-arterial (VA) ECMO support, anticoagulation practices are often the same across modalities. Moreover, there is very little data on their respective coagulation profiles and comparisons of thrombin generation in these patients.

View Article and Find Full Text PDF

The TEG® 5000 and novel TEG® 6s measure the viscoelasticity of whole blood during in vitro clot formation. The two devices measure similar coagulation variables but utilize distinctly different technologies. This study aimed to determine the correlation and agreement between the thrombelastographic parameters obtained by the two devices during liver transplant surgery.