Background: Follitropin Delta (FD) is indicated exclusively for in-vitro fertilization however, being a gonadotropin it could be used for other purposes. A dosing algorithm exists for FD and IVF but is needed for intrauterine insemination (IUI) cycles. The objective of this study is to determine dosing for FD for the first controlled ovarian hyperstimulation (COH) cycle according to current stimulation guidelines.
View Article and Find Full Text PDFObjective: To assess the effect of the total motile sperm counts (TMSC) on the success of controlled ovarian stimulation (COH) and intra-uterine insemination (IUI) in women 38-42 years of age.
Study Design: A database of all women aged 38-42 years who underwent IUI with stimulation at a University Reproductive Centre between 2009 and 2018 inclusive was developed. Including stimulation with clomiphene citrate, letrozole or gonadotropins and divided into TMSC 5.
Objective: To determine the diagnostic yield of repeated screening for atrial fibrillation (AF) among geriatric patients.
Methods: A pragmatic prospective cohort study into applying opportunistic screening for AF with a handheld single lead ECG device (SLD) in a geriatric cohort. Consecutive patients of 65 years old and older visiting the geriatric outpatient clinic were eligible for inclusion.
Background: Modern pacemakers continuously store significant cardiac-related events. Interpreting these data and reprogramming the pacemaker can be time-consuming and demands expert knowledge. A software-based expert system, the therapy advisor (TA), was developed, which analyzes stored data and provides reprogramming recommendations.
View Article and Find Full Text PDFBackground: This study investigated onset scenarios of atrial fibrillation (AF), the first phase of the Atrial Fibrillation Therapy (AFT) trial, to determine potential arrhythmogenic triggers as targets for atrial pacing algorithms that have been proposed for prevention of AF.
Methods And Results: Ninety-eight patients (58 men; age 65+/-11 years) with recurrent, symptomatic, drug-refractory AF and a conventional pacemaker indication in 31 of 98 received a dual-chamber pacemaker. Using novel diagnostic pacemaker features AF onset scenarios were prospectively evaluated in 612 AF episodes during a 2-month monitoring period, with atrial pacing limited to 40 bpm.
Pacing Clin Electrophysiol
March 2004
DDDR pacemakers with QT driven sensor algorithms may be susceptible to inappropriate pacemaker tachycardia when implanted into patients who have a relatively extended cardiac repolarization. The inability to detect and measure the QT interval at near maximum sensor rate, results in an inappropriate adjustment of the automatic QT slope. Triggering pacemaker induced tachycardia.
View Article and Find Full Text PDF