The purpose of this guideline is to assist specialists in Nuclear Medicine and Radionuclide Radiology in recommending, performing, interpreting and reporting the results of lacrimal scintigraphy (also known as Dacroscintigraphy). This guideline will assist individual departments to formulate their own local protocols. This does not aim to be prescriptive regarding technical aspects of individual camera acquisitions, which need to be developed in conjunction with the local experts in medical physics.
View Article and Find Full Text PDFc-MET and its ligand HGF are frequently overexpressed in colorectal cancer (CRC) and increased c-MET levels are found in CRC liver metastases. This study investigated the role of the HGF/c-MET axis in regulating migration/invasion in CRC, using pre-clinical models and clinical samples. Pre-clinically, we found marked upregulation of c-MET at both protein and mRNA levels in several invasive CRC cells.
View Article and Find Full Text PDFOwing to expanding clinical indications, cardiac implantable electronic devices (CIEDs) are being increasingly used. Despite improved surgical techniques and the use of prophylactic antimicrobial therapy, the rate of CIED-related infection is also increasing. Infection is a potentially serious complication, with clinical manifestations ranging from surgical site infection and local symptoms in the region of the generator pocket to fulminant endocarditis.
View Article and Find Full Text PDFObjectives: The last decade has seen considerable technological innovations in PET detectors with the availability, among other advances, of time-of-flight (TOF). TOF has been shown to increase the signal-to-noise ratio (SNR), which should allow for a reduction in acquired counts while maintaining image quality.
Methods: Fifty-eight patients referred for routine F-flurodeoxyglucose ((18)F-FDG) oncology PET studies were included in this study.
We report the case of a 52-year-old man who presented with a 2-week history of dyspnea and wheeze. CT scan of the chest showed a large soft-tissue lesion in the right main bronchus extending into the trachea. Pathologic examination of endoscopic tracheal biopsies showed features consistent with a non–small-cell lung carcinoma.
View Article and Find Full Text PDFAim: The aim of this study was to determine whether resolution recovery (RR) iterative reconstruction algorithms can consistently produce diagnostic quality myocardial perfusion SPECT images for the patient population routinely scanned in this department. Reduced-count data were compared with full-count data without RR according to our established protocol. The desired outcome would be to implement the software to allow a reduction in the administered activity for routine myocardial SPECT.
View Article and Find Full Text PDFBackground: Tissue MicroArrays (TMAs) are a valuable platform for tissue based translational research and the discovery of tissue biomarkers. The digitised TMA slides or TMA Virtual Slides, are ultra-large digital images, and can contain several hundred samples. The processing of such slides is time-consuming, bottlenecking a potentially high throughput platform.
View Article and Find Full Text PDFAnal Cell Pathol (Amst)
April 2011
Background: tissue MicroArrays (TMAs) are a valuable platform for tissue based translational research and the discovery of tissue biomarkers. The digitised TMA slides or TMA Virtual Slides, are ultra-large digital images, and can contain several hundred samples. The processing of such slides is time-consuming, bottlenecking a potentially high throughput platform.
View Article and Find Full Text PDFA 65-year-old man with known ischemic heart disease and previous coronary artery bypass grafts was admitted having been found collapsed in the street. He was a smoker with a history of alcohol abuse. On clinical examination he was unkempt, febrile, hemodynamically stable, and had no systemic deficits.
View Article and Find Full Text PDF