Publications by authors named "Jacek Wendykier"

Background: The aim of this study was to indicate the most favorable - in terms of to the time of calculation and the uncertainty of determining the dose distribution - values of the parameters for the Electron Monte Carlo (eMC) algorithm in the Eclipse treatment planning system.

Materials And Methods: Using the eMC algorithm and the variability of the values of its individual parameters, calculations of the electron dose distribution in the full-scattering virtual water phantom were performed, obtaining percentage depth doses, beam profiles, absolute dose values in points and calculation times. The reference data included water tank measurements such as relative dose distributions and absolute point doses.

View Article and Find Full Text PDF

Background: To properly configure a treatment planning system, a measurement data set is needed, which consists of the values required for its configuration. The aim is to obtain a dosimetric model of the beam that is as compatible as possible with the measured values. The set of required data can be supplemented with optional values.

View Article and Find Full Text PDF

Background: The comparison between profiles during the commissioning of the treatment planning system is an essential procedure. It is impossible to designate a field size for off-axis, wedged, and FFF beams directly by using the definition of the on-axis symmetric field size. This work proposes the use of different characteristic points as indicators of the field size for commissioning and QA purposes.

View Article and Find Full Text PDF

In the present study, we analyze the nuclear magnetic resonance (NMR) blood serum metabolic profiles of 106 head and neck squamous cell carcinoma (HNSCC) patients during radio (RT) and concurrent radio-chemotherapy (CHRT). Four different fractionation schemes were compared. The blood samples were collected weekly, from the day before the treatment until the last week of CHRT/RT.

View Article and Find Full Text PDF

The accuracy of radiotherapy is the subject of continuous discussion, and dosimetry methods, particularly in dynamic techniques, are being developed. At the same time, many oncology centers develop quality procedures, including pretreatment and online dose verification and proper patient tracking methods. This work aims to present the possibility of using portal dosimetry in the assessment of radiotherapy repeatability.

View Article and Find Full Text PDF

Aim: The aim of this study is to answer the question whether the calculated dose distributions for HD and Millennium collimators (Varian Medical Systems) are equivalent for large treatment volumes.

Background: Modern biomedical linacs are equipped with multileaf collimators where leaves can be of different widths. Thinner leaves allow better fit to desired (tumor) shape.

View Article and Find Full Text PDF

Background: To appraise the dosimetric features and the quality of the treatment plan for radiosurgery of multiple brain metastases optimized with a novel automated engine and to compare with plans optimized for robotic-based delivery.

Methods: A set of 15 patients with multiple brain metastases was selected for this in silico study. The technique under investigation is the recently introduced HyperArc.

View Article and Find Full Text PDF

Aim: This work addresses the problem of treatment planning system commissioning by introducing a new method of determination of boundaries between high and low gradient in beam profile.

Background: The commissioning of a treatment planning system is a very important task in the radiation therapy. One of the main goals of this task is to compare two field profiles: measured and calculated.

View Article and Find Full Text PDF

We examine the critical behavior of a lattice model of tumor growth where supplied nutrients are correlated with the distribution of tumor cells. Our results support the previous report [Ferreira et al., Phys.

View Article and Find Full Text PDF

In the present paper we study a lattice model of two species competing for the same resources. Monte Carlo simulations for d = 1,2, and 3 show that when resources are easily available both species coexist. However, when the supply of resources is on an intermediate level, the species with slower metabolism becomes extinct.

View Article and Find Full Text PDF