Publications by authors named "Jablonski G"

Article Synopsis
  • Perilymphatic fistula (PLF) is an inner ear condition where fluid leaks from the inner ear to the middle ear due to an abnormal connection, and early surgery may improve hearing and balance outcomes.
  • The study aims to systematically review existing literature on diagnostic tests for PLF to determine their accuracy in detecting this condition in humans.
  • Research will involve searching multiple databases for peer-reviewed articles, assessing the quality of the studies, and potentially synthesizing data from high-quality articles if applicable.
View Article and Find Full Text PDF

The objective to preserve residual hearing during cochlear implantation has recently led to the use of intracochlear electrocochleography (ECochG) as an intraoperative monitoring tool. Currently, a decrease in the amplitude of the difference between responses to alternating-polarity stimuli (DIF response), predominantly reflecting the hair cell response, is used for providing feedback. Including other ECochG response components, such as phase changes and harmonic distortions, could improve the accuracy of surgical feedback.

View Article and Find Full Text PDF

Hypothesis: Gross electrode movements detected with intraoperative, real-time X-ray fluoroscopy will correlate with fluctuations in cochlear output, as measured with intraoperative electrocochleography (ECochG).

Background: Indications for cochlear implantation (CI) are expanding to include patients with residual hearing; however, implant recipients often lose residual hearing after CI. The objective of this study was to identify probable traumatic events during implantation by combining electrophysiological monitoring of cochlear function with simultaneous X-ray monitoring.

View Article and Find Full Text PDF

Introduction: The main objective of the study was to validate the Norwegian translation of the Speech, Spatial and Qualities of Hearing Scale (SSQ) and investigate the SSQ disability profiles in a cochlear implant (CI) user population.

Methods: The study involved 152 adult CI users. The mean age at implantation was 55 (standard deviation [SD] = 16), and the mean CI experience was 5 years (SD = 4.

View Article and Find Full Text PDF

Science advances through the interplay of idea construction and idea critique. Our goal was to describe varied forms of productive disciplinary engagement that emerged during primary literature discussions. Such descriptions are necessary for biology educators and researchers to design for and recognize diverse repertoires of participation in the critique and discussion of primary scientific literature.

View Article and Find Full Text PDF

Background: The first surgeries with CI532 showed an effect of the proximity of the electrode to the modiolus on the Evoked Compound Action Potentials (ECAPs).

Objectives: Objectives of the study were to investigate the effect of the "pullback" procedure on intraoperative ECAP responses in three different electrode array positions and additionally to compare behavioral thresholds with the thresholds obtained in a group of patients using the standard insertion. The hypothesis of this study is that pullback will cause lower ECAPs and behavioral thresholds.

View Article and Find Full Text PDF

Background And Objective: The cochlear implant (CI) electrode insertion process is a key step in CI surgery. One of the aims of advances in robotic-assisted CI surgery (RACIS) is to realize better cochlear structure preservation and to precisely control insertion. The aim of this literature review is to gain insight into electrode selection for RACIS by acquiring a thorough knowledge of electrode insertion and related complications from classic CI surgery involving a manual electrode insertion process.

View Article and Find Full Text PDF

Although polymorphisms of adiponectin gene () in obesity-related conditions have been the target of research efforts, little is known about this genetic marker in uterine leiomyomas. The aim of this pilot study was to analyze the frequencies of alleles and genotypes of Single Nucleotide Polymorphism (NM_004797.4):c.

View Article and Find Full Text PDF

The HEARO cochlear implantation surgery aims to replace the conventional wide mastoidectomy approach with a minimally invasive direct cochlear access. The main advantage of the HEARO access would be that the trajectory accommodates the optimal and individualized insertion parameters such as type of cochlear access and trajectory angles into the cochlea. To investigate the quality of electrode insertion with the HEARO procedure, the insertion process was inspected under fluoroscopy in 16 human cadaver temporal bones.

View Article and Find Full Text PDF

Objectives: Head trauma may cause dislodgement of otoconia and development of benign paroxysmal positional vertigo (BPPV). The risk of developing BPPV is expected to be highest shortly after the trauma, then decrease and approach the risk seen in the general population. The aim of this study was to estimate the risk-time curve of BPPV development after head trauma.

View Article and Find Full Text PDF

Background: The aim of this study was to analyze the frequencies of genotypes and alleles of Single Nucleotide Polymorphism (SNP) LEP-R c.668A>G (p.Gln223Arg, rs1137101) of leptin receptor gene and to assess the influence this DNA marker has on endometrial cancer (EC) with respect to total body fat content.

View Article and Find Full Text PDF
Article Synopsis
  • Heart rate variability (HRV) refers to the differing lengths of time intervals between heartbeats and can indicate health issues.
  • Traditional HRV analysis uses time and frequency domain methods, but researchers are seeking better assessment tools.
  • This paper introduces a new way to analyze HRV using persistent homology, a method from algebraic topology, presenting new topological descriptors that may be effective in distinguishing healthy individuals from stroke patients.
View Article and Find Full Text PDF

The constant development and miniaturization of MEMS sensors invariably provides new possibilities for their use in health-related and medical applications. The application of MEMS devices in posturographic systems allows faster diagnosis and significantly facilitates the work of medical staff. MEMS accelerometers constitute a vital part of such systems, particularly those intended for monitoring patients with imbalance disorders.

View Article and Find Full Text PDF

Several methods of imaging the Eustachian tube have been tested in the last century, although neither has led to an established method. The introduction of balloon Eustachian tuboplasty (BET) has revived the request for Eustachian tube (ET) visualization in patients with chronic Eustachian tube dysfunction. Many institutions perform preoperative computed tomography (CT) scans of the temporal bone and epipharynx before BET.

View Article and Find Full Text PDF

Introduction: Endometriosis is a chronic disease defined by the presence of uterine mucosa outside the uterine cavity. Abnormal levels of cytokines, growth factors, adhesion molecules and metalloproteinases have been found in patients with endometriosis. A review of the literature revealed no papers on CCL20 serum levels in women with endometriosis.

View Article and Find Full Text PDF

Bionanocellulose (BNC) is a clear polymer produced by the bacterium Gluconacetobacter xylinus. In our current study, "Research on the use of bacterial nanocellulose (BNC) in regenerative medicine as a function of the biological implants in cardiac and vascular surgery", we carried out material analysis, biochemical analysis, in vitro tests and in vivo animal model testing. In stage 1 of the project, we carried out physical and biological tests of BNC.

View Article and Find Full Text PDF

Objectives: To present nine patients with an abnormal widened bony Eustachian tube running anteriorly in the skull base through the sphenoid bone.

Methods: Patients with a particular anomaly in the bony Eustachian tube incidentally found on CT examinations were registered consecutively over a period of four years.

Results: Nine patients had the anomaly, eight unilaterally and one bilaterally.

View Article and Find Full Text PDF

Background: Dystonia-deafness syndrome is a well-known clinical entity, with sensorineural deafness typically manifesting earlier than dystonia. ACTB p.Arg183Trp heterozygosity has been reported in six patients to cause combined infant-onset deafness and dystonia manifesting in adolescence or young adulthood.

View Article and Find Full Text PDF

Purpose: Balloon dilation of the Eustachian tube is a treatment option for obstructive Eustachian tube dysfunction. The desired balloon position is in the cartilaginous portion. However, the balloon catheter may slide into the bony portion without the surgeon's knowledge.

View Article and Find Full Text PDF

Objectives: We aim to develop an imaging technique for visualization of the Eustachian tube (ET) lumen.

Study Design: A prospective, experimental study in an animal model and in human cadaver specimens.

Methods: Applying iodixanol to the middle ear in two human temporal bone specimens, followed by computed tomography (CT) examinations, we optimized contrast dilution, CT algorithm, and head positioning for visualization of contrast passage through the ET.

View Article and Find Full Text PDF

Introduction: As of 2014 more than 1200 patients have received a cochlear implant (CI) at Oslo University Hospital (OUS) and approximately half of them have been children. The data obtained from these patients have been used to develop a comprehensive database for a systematic analysis of several objective measurements and programming measurements. During the past 10 years, we have used an objective measurements protocol for our CI surgeries.

View Article and Find Full Text PDF

Objectives: It has long been known that cochlear implantation may cause loss of residual hearing and vestibular function. Different insertion depths may cause varying degrees of intracochlear trauma in the apical region of the cochlea. The present study investigated the correlation between the insertion depth and postoperative loss of residual hearing and vestibular function.

View Article and Find Full Text PDF

The aim of this study was to compare the outcomes of vestibular tests and the residual hearing of patients who have undergone full insertion cochlear implant surgery using the round window approach with a hearing preservation protocol (RW-HP) or the standard cochleostomy approach (SCA) without hearing preservation. A prospective study of 34 adults who underwent unilateral cochlear implantation was carried out. One group was operated using the RW-HP (n = 17) approach with Med-El +Flex(SOFT) electrode array with full insertion, while the control group underwent a more conventional SCA surgery (n = 17) with shorter perimodiolar electrodes.

View Article and Find Full Text PDF

Background: A subset of hereditary cerebellar ataxias is inherited as autosomal recessive traits (ARCAs). Classification of recessive ataxias due to phenotypic differences in the cerebellum and cerebellar structures is constantly evolving due to new identified disease genes. Recently, reports have linked mutations in genes involved in ubiquitination (RNF216, OTUD4, STUB1) to ARCA with hypogonadism.

View Article and Find Full Text PDF

Objective: To evaluate the effect of the intracochlear electrode position on the residual hearing and VNG- and cVEMP responses.

Design: Prospective pilot study.

Study Sample: Thirteen adult patients who underwent unilateral cochlear implant surgery were examined with high-resolution rotational tomography after cochlear implantation.

View Article and Find Full Text PDF