We describe a deterministic lateral displacement (DLD) for particle separation with only a single column of bumping features. The bifurcation of fluid streams at obstacles is not set by the "tilt" of columns with respect to macroscopic current flow, but rather by the fluidic resistances for lateral flow at each obstacle. With one column of 14 bumping features and corresponding inlet/outlet channels, the single-column DLD can separate particles with diameters of 4.
View Article and Find Full Text PDFThe heterogenous, highly metabolic stressed, poorly irrigated, solid tumor microenvironment - the tumor swamp - is widely recognized to play an important role in cancer progression as well as the development of therapeutic resistance. It is thus important to create realistic in vitro models within the therapeutic pipeline that can recapitulate the fundamental stress features of the tumor swamp. Here we describe a microfluidic system which generates a chemical gradient within connected microenvironments achieved through a static diffusion mechanism rather than active pumping.
View Article and Find Full Text PDFDamage significantly influences response of a strain sensor only if it occurs in the proximity of the sensor. Thus, two-dimensional (2D) sensing sheets covering large areas offer reliable early-stage damage detection for structural health monitoring (SHM) applications. This paper presents a scalable sensing sheet design consisting of a dense array of thin-film resistive strain sensors.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
December 2019
Tactile sensing requires form-fitting and dense sensor arrays over large-areas. Hybrid systems, combining Large-Area Electronics (LAE) and silicon-CMOS ICs to respectively provide diverse sensing and high-performance computation/control, enable a platform for such sensing. A key challenge is that hybrid systems require a large number of interfaces between the LAE and CMOS domains, particularly as the number of sensors scales.
View Article and Find Full Text PDFConventional cell culture remains the most frequently used preclinical model, despite its proven limited ability to predict clinical results in cancer. Microfluidic cancer-on-chip models have been proposed to bridge the gap between the oversimplified conventional 2D cultures and more complicated animal models, which have limited ability to produce reliable and reproducible quantitative results. Here, we present a microfluidic cancer-on-chip model that reproduces key components of a complex tumor microenvironment in a comprehensive manner, yet is simple enough to provide robust quantitative descriptions of cancer dynamics.
View Article and Find Full Text PDFThe ability of a population of PC3 prostate epithelial cancer cells to become resistant to docetaxel therapy and progress to a mesenchymal state remains a fundamental problem. The progression towards resistance is difficult to directly study in heterogeneous ecological environments such as tumors. In this work, we use a micro-fabricated "evolution accelerator" environment to create a complex heterogeneous yet controllable in-vitro environment with a spatially-varying drug concentration.
View Article and Find Full Text PDFSensing sheets based on Large Area Electronics (LAE) and Integrated Circuits (ICs) are novel sensors designed to enable reliable early-stage detection of local unusual structural behaviors. Such a device consists of a dense array of strain sensors, patterned onto a flexible polyimide substrate along with associated electronics. Previous tests performed on steel specimens equipped with sensing sheet prototypes and subjected to fatigue cracking pointed to a potential issue: individual sensors that were on or near a crack would immediately be damaged by the crack, thereby rendering them useless in assessing the size of the crack opening or to monitor future crack growth.
View Article and Find Full Text PDFBackground: The physics of cancer dormancy, the time between initial cancer treatment and re-emergence after a protracted period, is a puzzle. Cancer cells interact with host cells via complex, non-linear population dynamics, which can lead to very non-intuitive but perhaps deterministic and understandable progression dynamics of cancer and dormancy.
Results: We explore here the dynamics of host-cancer cell populations in the presence of (1) payoffs gradients and (2) perturbations due to cell migration.
We have improved our microfluidic cell culture device that generates an landscape of stress heterogeneity. We now can do continuous observations of different cancer cell lines and carry out downstream analysis of cell phenotype as a function of position on the stress landscape. We use this technology to probe adaption and evolution dynamics in prostate cancer cell metapopulations under a stress landscape of a chemotherapeutic drug (docetaxel).
View Article and Find Full Text PDFReliable cell recovery and expansion are fundamental to the successful scale-up of chimeric antigen receptor (CAR) T cells or any therapeutic cell-manufacturing process. Here, we extend our previous work in whole blood by manufacturing a highly parallel deterministic lateral displacement (DLD) device incorporating diamond microposts and moving into processing, for the first time, apheresis blood products. This study demonstrates key metrics of cell recovery (80%) and platelet depletion (87%), and it shows that DLD T-cell preparations have high conversion to the T-central memory phenotype and expand well in culture, resulting in twofold greater central memory cells compared to Ficoll-Hypaque (Ficoll) and direct magnetic approaches.
View Article and Find Full Text PDFBiomicrofluidics
September 2017
Flow cytometry analysis requires a large amount of isolated, labelled, and purified cells for accurate results. To address the demand for a large quantity of cells prepared in a timely manner, we describe a novel microfluidic trap structure array for on-chip cell labelling, such as intracellular and extracellular labelling, and subsequent washing and release of cells. Each device contains [Formula: see text] trap structures, which made the preparation of large numbers of cells [Formula: see text] possible.
View Article and Find Full Text PDFWe previously developed a Deterministic Lateral Displacement (DLD) microfluidic method in silicon to separate cells of various sizes from blood (Davis et al., Proc Natl Acad Sci 2006;103:14779-14784; Huang et al., Science 2004;304:987-990).
View Article and Find Full Text PDFThe classical SiO2/Si interface, which is the basis of integrated circuit technology, is prepared by thermal oxidation followed by high temperature (>800 °C) annealing. Here we show that an interface synthesized between titanium dioxide (TiO2) and hydrogen-terminated silicon (H:Si) is a highly efficient solar cell heterojunction that can be prepared under typical laboratory conditions from a simple organometallic precursor. A thin film of TiO2 is grown on the surface of H:Si through a sequence of vapor deposition of titanium tetra(tert-butoxide) (1) and heating to 100 °C.
View Article and Find Full Text PDFWe describe a microfluidic device for on-chip chemical processing, such as staining, and subsequent washing of cells. The paper introduces "separator walls" to increase the on-chip incubation time and to improve the quality of washing. Cells of interest are concentrated into a treatment stream of chemical reagents at the first separator wall for extended on-chip incubation without causing excess contamination at the output due to diffusion of the unreacted treatment chemicals, and then are directed to the washing stream before final collections.
View Article and Find Full Text PDFProc Natl Acad Sci U S A
August 2015
We use a microfabricated ecology with a doxorubicin gradient and population fragmentation to produce a strong Darwinian selective pressure that drives forward the rapid emergence of doxorubicin resistance in multiple myeloma (MM) cancer cells. RNA sequencing of the resistant cells was used to examine (i) emergence of genes with high de novo substitution densities (i.e.
View Article and Find Full Text PDFWe demonstrate that a microfabricated bump array can concentrate genomic-length DNA molecules efficiently at continuous, high flow velocities, up to 40 μm/s, if the single-molecule DNA globule has a sufficiently large shear modulus. Increase in the shear modulus is accomplished by compacting the DNA molecules to minimal coil size using polyethylene glycol (PEG) derived depletion forces. We map out the sweet spot, where concentration occurs, as a function of PEG concentration and flow speed using a combination of theoretical analysis and experiment.
View Article and Find Full Text PDFIn this Research Article, we demonstrate pulsed laser processing of a silver nanowire network transparent conductor on top of an otherwise complete solar cell. The macroscopic pulsed laser irradiation serves to sinter nanowire-nanowire junctions on the nanoscale, leading to a much more conductive electrode. We fabricate hybrid silicon/organic heterojunction photovoltaic devices, which have ITO-free, solution processed, and laser processed transparent electrodes.
View Article and Find Full Text PDFMicrofluidic deterministic lateral displacement (DLD) arrays have been applied for fractionation and analysis of cells in quantities of ~100 μL of blood, with processing of larger quantities limited by clogging in the chip. In this paper, we (i) demonstrate that this clogging phenomenon is due to conventional platelet-driven clot formation, (ii) identify and inhibit the two dominant biological mechanisms driving this process, and (iii) characterize how further reductions in clot formation can be achieved through higher flow rates and blood dilution. Following from these three advances, we demonstrate processing of 14 mL equivalent volume of undiluted whole blood through a single DLD array in 38 minutes to harvest PC3 cancer cells with ~86% yield.
View Article and Find Full Text PDFThe transport of objects in microfluidic arrays of obstacles is a surprisingly rich area of physics and statistical mechanics. Tom Duke's mastery of these areas had a major impact in the development of biotechnology which uses these ideas at an increasing scale. We first review how biological objects are transported in fluids at low Reynolds numbers, including a discussion of electrophoresis, then concentrate on the separation of objects in asymmetric arrays, sometimes called Brownian ratchets when diffusional symmetry is broken by the structures.
View Article and Find Full Text PDFDo genetically closely related organisms under identical, but strong selection pressure converge to a common resistant genotype or will they diverge to different genomic solutions? This question gets at the heart of how rough is the fitness landscape in the local vicinity of two closely related strains under stress. We chose a Growth Advantage in Stationary Phase (GASP) E scherichia coli strain to address this question because the GASP strain has very similar fitness to the wild-type (WT) strain in the absence of metabolic stress but in the presence of metabolic stress continues to divide and does not enter into stationary phase. We find that under strong antibiotic selection pressure by the fluoroquinolone antibiotic ciprofloxacin in a complex ecology that the GASP strain rapidly evolves in under 20 h missense mutation in gyrA only 2 amino acids removed from the WT strain indicating a convergent solution, yet does not evolve the other 3 mutations of the WT strain.
View Article and Find Full Text PDFPreventing relapse is the major challenge to effective therapy in cancer. Within the tumour, stromal (ST) cells play an important role in cancer progression and the emergence of drug resistance. During cancer treatment, the fitness of cancer cells can be enhanced by ST cells because their molecular signalling interaction delays the drug-induced apoptosis of cancer cells.
View Article and Find Full Text PDFProc Natl Acad Sci U S A
October 2013
The emergence of resistance to chemotherapy by cancer cells, when combined with metastasis, is the primary driver of mortality in cancer and has proven to be refractory to many efforts. Theory and computer modeling suggest that the rate of emergence of resistance is driven by the strong selective pressure of mutagenic chemotherapy and enhanced by the motility of mutant cells in a chemotherapy gradient to areas of higher drug concentration and lower population competition. To test these models, we constructed a synthetic microecology which superposed a mutagenic doxorubicin gradient across a population of motile, metastatic breast cancer cells (MDA-MB-231).
View Article and Find Full Text PDFMetastasis, the truly lethal aspect of cancer, occurs when metastatic cancer cells in a tumor break through the basement membrane and penetrate the extracellular matrix. We show that MDA-MB-231 metastatic breast cancer cells cooperatively invade a 3D collagen matrix while following a glucose gradient. The invasion front of the cells is a dynamic one, with different cells assuming the lead on a time scale of 70 h.
View Article and Find Full Text PDFCirculating tumor cells (CTCs) and circulating clusters of cancer and stromal cells have been identified in the blood of patients with malignant cancer and can be used as a diagnostic for disease severity, assess the efficacy of different treatment strategies and possibly determine the eventual location of metastatic invasions for possible treatment. There is thus a critical need to isolate, propagate and characterize viable CTCs and clusters of cancer cells with their associated stroma cells. Here, we present a microfluidic device for mL/min flow rate, continuous-flow capture of viable CTCs from blood using deterministic lateral displacement (DLD) arrays.
View Article and Find Full Text PDFA hybrid approach to solar cells is demonstrated in which a silicon p-n junction, used in conventional silicon-based photovoltaics, is replaced by a room-temperature fabricated silicon/organic heterojunction. The unique advantage of silicon/organic heterojunction is that it exploits the cost advantage of organic semiconductors and the performance advantages of silicon to enable potentially low-cost, efficient solar cells.
View Article and Find Full Text PDF