Gantry-free cone-beam CT (CBCT) allows for ultra-high-resolution (UHR) upper extremity imaging in a comfortable tableside position. The aim of this study was to assess the organ-specific radiation burden and the effect of dedicated lead shielding in the UHR-CBCT of the wrist and elbow. A modified Alderson-Rando phantom was scanned with the tableside UHR-CBCT mode of a twin robotic X-ray system employing identical scan parameters for wrist and elbow imaging.
View Article and Find Full Text PDFBackground And Purpose: Anatomically adapted cochlear implantation and efficient postoperative cochlear implant-fitting strategies benefit from reliable and highly detailed imaging techniques. Since image quality in CT is related to the applied radiation dose, this study aimed to evaluate low-dose cochlear imaging with a photon-counting detector by investigating the accuracy of pre- and postoperative cochlear analysis.
Materials And Methods: Photon-counting CT images of 10 temporal bone specimens were acquired with 3 different radiation dose levels (regular dose: 27.
Rationale And Objectives: Pulmonary magnetic resonance angiography (MRA) is an imaging method with proven utility for the exclusion of pulmonary embolism and avoids the need for ionizing radiation and iodinated contrast agents. High-relaxivity gadolinium-based contrast agents (GBCAs), such as gadopiclenol, can be used to reduce the required gadolinium dose for pulmonary MRA. The aim of this study was to compare the contrast enhancement performance of gadopiclenol with an established gadobenate dimeglumine-enhanced pulmonary MRA protocol.
View Article and Find Full Text PDFRationale And Objectives: Suspicious lesions detected in multiparametric breast MRI can be further analyzed with second-look ultrasound (SLUS) and/or mammography. This study aims to assess the value of second-look imaging in selecting the appropriate biopsy method for different lesion characteristics.
Materials And Methods: Between January 2021 and December 2023, 212 women underwent contrast-enhanced multiparametric breast MRI at 3 Tesla.
Purpose: To evaluate a novel flow-independent sequence (Relaxation-Enhanced Angiography without Contrast and Triggering (REACT)) for imaging of the extracranial arteries in acute ischemic stroke (AIS) at 1.5 T.
Methods: This retrospective single-center study included 47 AIS patients who received REACT (scan time: 3:01 min) and contrast-enhanced MRA (CE-MRA) of the extracranial arteries at 1.
Background: Excess fibrotic remodeling causes cardiac dysfunction in ischemic heart disease, driven by MAP (mitogen-activated protein) kinase-dependent TGF-ß1 (transforming growth factor-ß1) activation by coagulation signaling of myeloid cells. How coagulation-inflammatory circuits can be specifically targeted to achieve beneficial macrophage reprogramming after myocardial infarction (MI) is not completely understood.
Methods: Mice with permanent ligation of the left anterior descending artery were used to model nonreperfused MI and analyzed by single-cell RNA sequencing, protein expression changes, confocal microscopy, and longitudinal monitoring of recovery.
Background And Aims: The aim of this study was to investigate the imaging performance and quality differences of PCD-CT in standard resolution mode (SR) versus ultra-high resolution mode (UHR) in the lower extremity runoff of dose-matched CTAs in a human cadaveric model.
Methods: Extracorporeal perfusion of the upper leg was established in one fresh-frozen human cadaver via inguinal and popliteal accesses using a peristaltic pump. Seven peripheral stents were deployed in the SFA.
Background Contrast-unenhanced abdominal CT is the imaging standard for urinary calculi detection; however, studies comparing photon-counting detector (PCD) CT and energy-integrating detector (EID) CT dose-reduction potentials are lacking. Purpose To compare the radiation dose and image quality of optimized EID CT with those of an experimental PCD CT scan protocol including tin prefiltration in patients suspected of having urinary calculi. Materials and Methods This retrospective single-center study included patients who underwent unenhanced abdominal PCD CT or EID CT for suspected urinary caliculi between February 2022 and March 2023.
View Article and Find Full Text PDFAcad Radiol
December 2024
Rationale And Objectives: To assess image quality and radiation dose of ultra-high-pitch CT pulmonary angiography (CTPA) with free-breathing technique for diagnosis of pulmonary embolism using a photon-counting detector (PCD) CT compared to matched energy-integrating detector (EID)-based single-energy CTPA.
Materials And Methods: Fifty-one PCD-CTPAs were prospectively compared to 51 CTPAs on a third-generation dual-source EID-CT. CTPAs were acquired with an ultra-high-pitch protocol with free-breathing technique (40 mL contrast medium, pitch 3.
Rationale And Objectives: This study investigates the performance of tomosynthesis in the presence of osteosynthetic implants, aiming to overcome superimposition-induced limitations in conventional radiograms.
Materials And Methods: After surgical fracture induction and subsequent osteosynthesis, 8 cadaveric fracture models (wrist, metacarpus, ankle, metatarsus) were scanned with the prototypical tomosynthesis mode of a multiuse x-ray system. Tomosynthesis protocols at 60, 80, and 116 kV (sweep angle 10°, 13 FPS) were compared with standard radiograms.
This study investigated whether virtual monoenergetic images (VMIs) and iodine mapping based on dual-energy CT (DECT) provide advantages in the assessment of endometrial cancer. A dual-source DECT was performed for primary staging of histologically proven endometrioid adenocarcinoma in 21 women (66.8 ± 12.
View Article and Find Full Text PDFObjectives: Image acquisition in ultra-high-resolution (UHR) scan mode does not impose a dose penalty in photon-counting CT (PCCT). This study aims to investigate the dose saving potential of using UHR instead of standard-resolution PCCT for lumbar spine imaging.
Materials And Methods: Eight cadaveric specimens were examined with 7 dose levels (5-35 mGy) each in UHR (120 × 0.
This retrospective study aims to provide an intra-individual comparison of aortic CT angiographies (CTAs) using first-generation photon-counting-detector CT (PCD-CT) and third-generation energy-integrating-detector CT (EID-CT). High-pitch CTAs were performed with both scanners and equal contrast-agent protocols. EID-CT employed automatic tube voltage selection (90/100 kVp) with reference tube current of 434/350 mAs, whereas multi-energy PCD-CT scans were generated with fixed tube voltage (120 kVp), image quality level of 64, and reconstructed as 55 keV monoenergetic images.
View Article and Find Full Text PDFPurpose: Since organ-based tube current modulation (OBTCM) and tin prefiltration are limited on their own in lowering the dose of lung CT examinations, this experimental study was designed to investigate whether combinations with anterior patient shielding can increase the dose reduction potential.
Material And Methods: Three pairs of scan protocols without/with breast shield (P1/P2: standard 120kVp, P3/P4: OBTCM at 100 kVp, P5/P6: Sn 100 kVp) were employed for radiation exposure and image quality comparisons on an anthropomorphic Alderson-Rando phantom. Equivalent doses were measured in eleven sites via thermoluminescent dosimetry and the effective dose was obtained by summation of the weighted organ doses.
Background And Aims: This study aims to compare the performance of first-generation dual-source photon-counting detector computed tomography (PCD-CT) to third-generation dual-source energy-integrating detector (EID-CT) regarding stent imaging in the femoral arterial runoff.
Methods: Continuous extracorporeal perfusion was established in 1 human cadaver using an inguinal and infragenicular access and peristaltic pump. Seven peripheral stents were implanted into both superior femoral arteries by means of percutaneous angioplasty.
Rationale And Objectives: This experimental study investigates the potential of lumbar spine tomosynthesis to offset the traditional limitations of radiographic and computed tomography imaging, that is, superimposition of anatomy and disregard of physiological load-bearing.
Materials And Methods: A gantry-free twin robotic scanner was used to obtain lateral radiographs and tomosyntheses of the lumbar spine under weight-bearing conditions in eight body donors. Tomosynthesis protocols varied in terms of sweep angle (20 versus 40°), scan time (2.
Multiple myeloma (MM) frequently induces persisting osteolytic manifestations despite hematologic treatment response. This study aimed to establish a biometrically valid study endpoint for bone remineralization through quantitative and qualitative analyses in sequential CT scans. Twenty patients (seven women, 58 ± 8 years) with newly diagnosed MM received standardized induction therapy comprising the anti-SLAMF7 antibody elotuzumab, carfilzomib, lenalidomide, and dexamethasone (E-KRd).
View Article and Find Full Text PDFObjectives: The aim of this study was to investigate potential benefits of ultra-high resolution (UHR) over standard resolution scan mode in ultra-low dose photon-counting detector CT (PCD-CT) of the lung.
Materials And Methods: Six cadaveric specimens were examined with 5 dose settings using tin prefiltration, each in UHR (120 × 0.2 mm) and standard mode (144 × 0.
Recent dissection studies resulted in the introduction of the term "chiasma antebrachii", which represents an intersection of the flexor digitorum superficialis (FDS) tendons for digits 2 and 3 in the distal third of the forearm. This retrospective investigation aimed to provide an MRI-based morphologic analysis of the chiasma antebrachii. In 89 patients (41 women, 39.
View Article and Find Full Text PDFObjectives: To investigate photon-counting CT (PCCT)-derived virtual monoenergetic images (VMI) for artifact reduction in patients with unilateral total hip replacements (THR).
Methods: Forty-two patients with THR and portal-venous phase PCCT of the abdomen and pelvis were retrospectively included. For the quantitative analysis, region of interest (ROI)-based measurements of hypodense and hyperdense artifacts, as well as of artifact-impaired bone and the urinary bladder, were conducted, and corrected attenuation and image noise were calculated as the difference of attenuation and noise between artifact-impaired and normal tissue.
Background The triple combination of the cystic fibrosis transmembrane regulator (CFTR) modulators elexacaftor, tezacaftor, and ivacaftor (hereafter, elexacaftor/tezacaftor/ivacaftor) has a positive effect on lung function in patients with cystic fibrosis (CF). Purpose To compare three-dimensional (3D) ultrashort echo time (UTE) MRI functional lung data to common functional lung parameters in assessing lung function in patients with CF undergoing elexacaftor/tezacaftor/ivacaftor therapy. Materials and Methods In this prospective feasibility study, 16 participants with CF consented to undergo pulmonary MRI with a breath-hold 3D UTE sequence at baseline (April 2018-June 2019) and follow-up (April-July 2021).
View Article and Find Full Text PDFPurpose: The effect of static forces under load limits the prognostic value of lumbar spine CT in a horizontal position. Using a gantry-free scanner architecture, this study was designed to assess the feasibility of weight-bearing cone-beam CT (CBCT) of the lumbar spine and to establish the most dose-effective combination of scan parameters.
Methods: Eight formalin-fixated cadaveric specimens were examined with a gantry-free CBCT system in upright position with the aid of a dedicated positioning backstop.
In this study, the impact of reconstruction sharpness on the visualization of the appendicular skeleton in ultrahigh-resolution (UHR) photon-counting detector (PCD) CT was investigated. Sixteen cadaveric extremities (eight fractured) were examined with a standardized 120 kVp scan protocol (CTDI 10 mGy). Images were reconstructed with the sharpest non-UHR kernel (Br76) and all available UHR kernels (Br80 to Br96).
View Article and Find Full Text PDF