Publications by authors named "J Zavatsky"

Background: Pedicle subtraction osteotomy (PSO) is effective for correcting spinal malalignment but is associated with high complication rates. The biomechanical effect of different PSO levels remains unclear, and no finite element (FE) analysis has compared L2-, L3-, L4-, and L5-PSOs.

Purpose: To assess the effects of PSO level on the spine's global range of motion, stresses on posterior instrumentation, load sharing with the anterior column, and proximal junctional stresses.

View Article and Find Full Text PDF

Purpose: Multi-rod constructs are used commonly to stabilize pedicle subtraction osteotomies (PSO). This study aimed to evaluate biomechanical properties of different satellite rod configurations and effects of screw-type spanning a PSO.

Methods: A validated 3D spinopelvic finite element model with a L3 PSO (30°) was used to evaluate 5 models: (1) Control (T10-pelvis + 2 rods); (2) lateral satellite rods connected via offsets to monoaxial screws (LatSat-Mono) or (3) polyaxial screws (LatSat-Poly); (4) in-line satellite rods connected to monoaxial screws (InSat-Mono) or (4) polyaxial screws (InSat-Poly).

View Article and Find Full Text PDF

Study Design: Finite element (FE) study.

Objective: Pedicle subtraction osteotomy (PSO) is a surgical method to correct sagittal plane deformities. In this study, we aimed to investigate the biomechanical effects of lumbar disc degeneration on the instrumentation following PSO and assess the effects of using interbody spacers adjacent to the PSO level in a long instrumented spinal construct.

View Article and Find Full Text PDF

Purpose: Lumbar procedures for Transforaminal Lumbar Interbody Fusion (TLIF) range from open (OS) to minimally invasive surgeries (MIS) to preserve paraspinal musculature. We quantify the biomechanics of cross-sectional area (CSA) reduction of paraspinal muscles following TLIF on the adjacent segments.

Methods: ROM was acquired from a thoracolumbar ribcage finite element (FE) model across each FSU for flexion-extension.

View Article and Find Full Text PDF

In the normal spine due to its curvature in various regions, C7 plumb line (C7PL) passes through the sacrum so that the head is centered over the pelvis-ball and socket hip joints and ankle joints. This configuration leads to the least muscular activities to maintain the spinal balance. For any reason like deformity, scoliosis, kyphosis, trauma, and/or surgery this optimal configuration gets disturbed requiring higher muscular activity to maintain the posture and balance.

View Article and Find Full Text PDF