Publications by authors named "J W Bill Whitlow"

Simulating the quantum dynamics of molecules in the condensed phase represents a longstanding challenge in chemistry. Trapped-ion quantum systems may serve as a platform for the analog-quantum simulation of chemical dynamics that is beyond the reach of current classical-digital simulation. To identify a 'quantum advantage' for these simulations, performance analysis of both analog-quantum simulation on noisy hardware and classical-digital algorithms is needed.

View Article and Find Full Text PDF

Conical intersections often control the reaction products of photochemical processes and occur when two electronic potential energy surfaces intersect. Theory predicts that the conical intersection will result in a geometric phase for a wavepacket on the ground potential energy surface, and although conical intersections have been observed experimentally, the geometric phase has not been directly observed in a molecular system. Here we use a trapped atomic ion system to perform a quantum simulation of a conical intersection.

View Article and Find Full Text PDF

In this review, we take a critical look at the methods used to document habituation and the theoretical assumptions that have been made about it. We point out problems associated with measuring habituation merely as a change over the course of repeated presentations of a stimulus. We argue that a common test procedure is essential to assess the relative magnitudes of habituation learning especially when different training procedures are examined.

View Article and Find Full Text PDF

Trapped atomic ions are a versatile platform for studying interactions between spins and bosons by coupling the internal states of the ions to their motion. Measurement of complex motional states with multiple modes is challenging, because all motional state populations can only be measured indirectly through the spin state of ions. Here we present a general method to determine the Fock state distributions and to reconstruct the density matrix of an arbitrary multimode motional state.

View Article and Find Full Text PDF

Background: Secretion of cardioprotective B-type natriuretic peptide 1-32 (BNP1-32) is increased proportionately with cardiac dysfunction, but its measurement in plasma is difficult. Therefore, less specific BNP and amino-terminal proBNP (NT-proBNP) assays that detect the precursor molecule proBNP alongside BNP or NT-proBNP metabolites were developed to reflect BNP1-32 secretion and are now mandated in the diagnosis of heart failure (HF). We compared the diagnostic performance of 2 widely used clinical assays: the Roche proBNPII assay, and Abbott BNP assay, against our recently developed in-house assays that measure either intact BNP1-32 or NT-proBNP.

View Article and Find Full Text PDF