Publications by authors named "J Vossoughi"

Objective: Exercise-induced laryngeal obstruction (EILO) occurs with paradoxical vocal fold motion or supraglottic collapse during moderate to vigorous exercise. Previously, Gallena et al (2015) reported lower-than-normal inspiratory (R) and expiratory (R) resistances during resting tidal breathing (RTB) in female teenage athletes with EILO. This study aimed to replicate that unexpected result.

View Article and Find Full Text PDF

Purpose The aim of the study was to develop a treatment for athletes with paradoxical vocal fold motion disorder (PVFMD) based on exercise physiology and learning theory principles and administer it over a preestablished time frame. Method A prospective, repeated-measures, within-subject group design was used. Eleven adolescent/teen athletes diagnosed with PVFMD via laryngoscopy received short-term intensive (STI) therapy.

View Article and Find Full Text PDF

Introduction: Following reports of respiratory symptoms among service members returning from deployment to South West Asia (SWA), an expert panel recommended pre-deployment spirometry be used to assess disease burden. Unfortunately, testing with spirometry is high cost and time-consuming. The airflow perturbation device (APD) is a handheld monitor that rapidly measures respiratory resistance (APD-Rr) and has promising but limited clinical data.

View Article and Find Full Text PDF

Purpose: An investigational, portable instrument was used to assess inspiratory (R(i)) and expiratory (R(e)) resistances during resting tidal breathing (RTB), postexercise breathing (PEB), and recovery breathing (RB) in athletes with and without paradoxical vocal fold motion disorder (PVFMD).

Method: Prospective, controlled, repeated measures within-subject and between-groups design. Twenty-four teenage female athletes, 12 with and 12 without PVFMD, breathed into the Airflow Perturbation Device for baseline measures of respiratory resistance and for two successive 1-min trials after treadmill running for up to 12 min.

View Article and Find Full Text PDF

Purpose: In this study, the authors aimed to determine reliability of the airflow perturbation device (APD) to measure respiratory resistance within and across sessions during resting tidal (RTB) and postexercise breathing in healthy athletes, and during RTB across trials within a session in athletes with paradoxical vocal fold motion (PVFM) disorder.

Method: Prospective, repeated-measures design. The APD measured respiratory resistance during 3 baseline assessments in 24 teenage female athletes, 12 with and 12 without PVFM.

View Article and Find Full Text PDF