Health Phys
February 2001
The ICRP Publication 65 recommends 200-600 Bq x m(-3) as the indoor radon action level for the general public. In Slovenia, a value of 400 Bq x m(-3) has been proposed but not yet approved. In a nation-wide radon project financed by the Health Inspectorate of Slovenia, it was discovered that the elementary school named "S3" belongs to a group of schools with elevated winter indoor radon concentrations up to 7,000 Bq x m(-3).
View Article and Find Full Text PDFDue to the specific work regime in the Postojna Cave, which depends primarily on the daily number of visitors, and on seasonal variations in air radon concentrations, an optimal methodology for radon and progeny measurement and dose calculation was sought. The program of measurement throughout the years was optimized, and now comprises 3-mo exposures of etched-track detectors, and twice a year, 8-10-d measurements using continuous monitors. Radon concentrations range from about 500 Bq m(-3) in winter to about 6,000 Bq m(-3) in summer, and equilibrium factors range from 0.
View Article and Find Full Text PDF