Oncologist
December 2016
Lessons Learned: Cabazitaxel has activity in squamous cell carcinoma of the head and neck (SCCHN) and taxane-resistant cell lines. For the first time, cabazitaxel was investigated in incurable patients with recurrent SCCHN. Patients were randomly assigned to cabazitaxel every 3 weeks or weekly methotrexate.
View Article and Find Full Text PDFBackground: This phase II study assessed the safety and efficacy of everolimus, an oral mammalian target of rapamycin inhibitor in advanced transitional carcinoma cell (TCC) after failure of platinum-based therapy.
Patients And Methods: Thirty-seven patients with advanced TCC received everolimus 10 mg/day until progressive disease (PD) or unacceptable toxicity. The primary end point was the disease control rate (DCR), defined as either stable disease (SD), partial response (PR), or complete response at 8 weeks.
Unlabelled: This study evaluated a novel high-resolution breast-specific gamma camera (HRBGC) for the detection of suggestive breast lesions.
Methods: Fifty patients (with 58 breast lesions) for whom a scintimammogram was clinically indicated were prospectively evaluated with a general-purpose gamma camera and a novel HRBGC prototype. The results of conventional and high-resolution nuclear studies were prospectively classified as negative (normal or benign) or positive (suggestive or malignant) by 2 radiologists who were unaware of the mammographic and histologic results.
J Ultrasound Med
September 2001
Objective: Large-core needle biopsy of the breast can be performed with stereotactic or ultrasonographic guidance. However, ultrasonographically guided large-core needle biopsy has notable advantages, including the absence of ionizing radiation, increased patient comfort, and greater cost-effectiveness. The purpose of this study was to evaluate the accuracy of ultrasonographically guided large-core needle biopsy for the diagnosis of breast cancer in palpable and nonpalpable breast masses.
View Article and Find Full Text PDFPurpose: To compare the accuracy of diagnosis of invasive breast cancer with 11- and 8-gauge stereotactic vacuum-assisted biopsy (SVAB) devices and to correlate lesion diameter and accuracy of breast cancer diagnosis at SVAB.
Materials And Methods: During a 22-month period, 489 SVAB procedures were performed with an 11-gauge probe and 305 with an 8-gauge probe. SVAB and surgical pathologic results of 104 breast carcinomas were reviewed and correlated with lesion size, number of specimens obtained, and type of SVAB probe used.