Publications by authors named "J Sadilek"

This paper investigates the effect of plasticizer structure on especially the printability and mechanical and thermal properties of poly(3-hydroxybutyrate)-poly(lactic acid)-plasticizer biodegradable blends. Three plasticizers, acetyl tris(2-ethylhexyl) citrate, tris(2-ethylhexyl) citrate, and poly(ethylene glycol)bis(2-ethylhexanoate), were first checked whether they were miscible with poly(3-hydroxybutyrate)-poly(lactic acid) (PHB-PLA) blends using a kneading machine. PHB-PLA-plasticizer blends of 60-25-15 (wt.

View Article and Find Full Text PDF

Spin liquids are correlated, disordered states of matter that fluctuate even at low temperatures. Experimentally, the extensive degeneracy characterizing their low-energy manifold is expected to be lifted, for example, because of dipolar interactions, leading to an ordered ground state at absolute zero. However, this is not what is usually observed, and many systems, whether they are chemically synthesized or nanofabricated, dynamically freeze before magnetic ordering sets in.

View Article and Find Full Text PDF

X-ray photoemission electron microscopy, one of the most successful imaging tools at synchrotrons, is known to have limitations related to the application of external fields and to the short electron mean free path. In order to overcome such issues, we adapt an existing XPEEM instrument to simultaneously perform coherent x-ray scattering measurements in reflectivity mode, thus adding a complementary method to XPEEM. Photon-in photon-out x-ray scattering provides the sensitivity to buried interfaces as well as the possibility to work under external fields, which is challenging when using charged particles for imaging.

View Article and Find Full Text PDF

Calibrated adsorption-based passive samplers were used for time-integrative monitoring of microcystins (MCs) in three full-scale drinking water treatment plants (DWTPs) in the Czech Republic during two vegetation seasons (Jun-Nov), in parallel with traditional discrete sampling. MCs were detected in epilimnetic water samples at concentrations up to 14 μg/L, but their levels in raw water in DWTPs were below 1 μg/L WHO guideline value for drinking water. Conventional treatment technologies (coagulation/filtration) eliminated cyanobacteria and intracellular toxins but had a limited removal efficiency for extracellular toxins.

View Article and Find Full Text PDF

Gas nanosensors, comprised of arrays of nanoelectrodes with finger-widths of ∼100 nm developed by electron beam lithography and aerosol assisted chemical vapor deposited non-functionalized and Pt-functionalized tungsten oxide nanowires (<100 nm) subsequently integrated across the pairs of electrodes via the dielectrophoresis method, are developed in this work. The functionality of these devices is validated towards various concentrations of NO2 and C2H5OH. The results demonstrate reproducible and consistent responses with better sensitivity and partial selectivity for the non-functionalized systems to NO2, as opposed to the Pt-functionalized systems, which display better sensing properties towards C2H5OH with a loss of response to NO2.

View Article and Find Full Text PDF