Publications by authors named "J Roehm"

Objective: To characterize the use and impact of radiation dose reduction techniques in actual practice for routine abdomen CT.

Methods: We retrospectively analyzed consecutive routine abdomen CT scans in adults from a large dose registry, contributed by 95 hospitals and imaging facilities. Grouping exams into deciles by, first, patient size, and second, size-adjusted dose length product (DLP), we summarized dose and technical parameters and estimated which parameters contributed most to between-protocols dose variation.

View Article and Find Full Text PDF

Ob Jectives: The European Society of Radiology identified 10 common indications for computed tomography (CT) as part of the European Study on Clinical Diagnostic Reference Levels (DRLs, EUCLID), to help standardize radiation doses. The objective of this study is to generate DRLs and median doses for these indications using data from the UCSF CT International Dose Registry.

Methods: Standardized data on 3.

View Article and Find Full Text PDF

Importance: Computed tomography (CT) radiation doses vary across institutions and are often higher than needed.

Objective: To assess the effectiveness of 2 interventions to reduce radiation doses in patients undergoing CT.

Design, Setting, And Participants: This randomized clinical trial included 864 080 adults older than 18 years who underwent CT of the abdomen, chest, combined abdomen and chest, or head at 100 facilities in 6 countries from November 1, 2015, to September 21, 2017.

View Article and Find Full Text PDF

Purpose: To report percutaneous transcranial puncture, embolization and occlusion of a very symptomatic hypoglossal canal/anterior condylar vein dural arteriovenous fistula (DAVF) using syngo iGuide navigational software in a patient in whom transarterial and transvenous embolization and surgery had failed.

Methods: After unsuccessful arterial and venous embolization and surgical treatment of a symptomatic hypoglossal canal DAVF, a 47-year-old man was transferred for further management. With exquisite anatomic detail provided by C-arm cone-beam computed tomography (CBCT) equipment (Artis zee Biplane, Dyna CT VC21H, Siemens Healthcare GmbH, Germany) and syngo iGuide needle guidance navigational software (Siemens Healthcare GmbHy) for planning a safe direct approach, the hypoglossal/anterior condylar vein, the dominant outflow vein of the fistula, was needle punctured percutaneously at the hypoglossal foramen and occluded with ethylene vinyl alcohol copolymer liquid embolic agent (Onyx, Medtronic, Minneapolis, Minnesota, USA) after placing two anchoring platinum coils (Target detachable coils, Stryker Neurovascular, Fremont, California, USA).

View Article and Find Full Text PDF

Background: Stroke due to the release of embolic debris during the placement of a stent to correct carotid artery stenosis is a constant procedural and peri-procedural threat. The new all metal Casper stent has been created with two layers of nitinol, the inner layer of which has pores diminutive enough to prevent embolic release.

Objective: To evaluate the safety, effectiveness, and utility of the double layer nitinol Casper carotid artery stent in the treatment of patients with severe carotid artery stenosis.

View Article and Find Full Text PDF